Authorized Panduit Distributor
Panduit FMD2 - The Opticom Fiber Drawer is designed to organize fiber distribution when space is limited. The drawer is completely modular and accommodates up to 8 QuickNet cassettes, FAP and FMP adapter panels as well as 96 fiber and copper cables. The fiber drawer is steel, black, has 8 ports and fits in a 2 RU footprint.

Panduit FMD2 The Opticom Fiber Drawer is designed to organize fiber distribution when space is…

UPC: 074983854783


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit Opticom FMD2 Fiber Drawer is a modular, space-saving solution designed for efficient fiber distribution in constrained environments. This 2 RU steel drawer accommodates up to 8 QuickNet cassettes, FAP and FMP adapter panels, and supports 96 fiber and copper cables, making it ideal for data centers, SANs, healthcare facilities, and central offices. The black steel construction ensures durability while the modular design allows for flexible configuration to meet specific network requirements. With 8 ports, the FMD2 optimizes cable management and simplifies maintenance by centralizing fiber distribution in a compact footprint. The drawer’s design supports high-density applications, including 10G/40G/100G/200G/400G system migrations, ensuring long-term scalability. Compatible with various modular cassettes, the FMD2 accommodates MTP/MPO-LC preterminated cassettes with 24F fiber capacity, supporting OS2, OM3, OM4, and OM5 fiber types. The built-in front cable management tray enhances patch cord organization, reducing clutter and improving airflow. Installation is straightforward, with the FMD2 designed to integrate seamlessly into existing infrastructure. Whether deployed in data centers, medical facilities, or enterprise networks, the Opticom FMD2 delivers reliable, high-performance fiber distribution in a compact 2 RU form factor.
  • 2 RU modular steel drawer for compact fiber distribution
  • Supports up to 8 QuickNet cassettes, FAP, and FMP adapter panels
  • Accommodates 96 fiber and copper cables
  • 8 ports for high-density fiber management
  • Compatible with OS2, OM3, OM4, and OM5 fiber types

Specifications

Application
Fiber Optic Cable Management
Color
Black
Depth
15.4 In.
Standard
RoHS Compliant
Type
Fiber Optic Drawer
Width
19.85 In.
Package Dimensions (L x W x H)
21 IN x 19.2 IN x 6.3 IN
Package Weight (Imperial)
15 lbs
The Opticom Fiber Drawer is designed to organize fiber distribution when space is limited. The drawer is completely modular and accommodates up to 4 QuickNet cassettes, FAP and FMP adapter panels as well as 48 fiber and copper cables. The fiber drawer is steel, black, has 4 ports and fits in a 1 RU footprint.

FMD1

The Opticom Fiber Drawer is designed to organize fiber distribution when space is limited. The drawer is completely modular and accommodates up to 4 QuickNet cassettes, FAP and FMP adapter panels as well as 48 fiber and copper cables. The fiber drawer is steel, black, has 4 ports and fits in a 1 RU footprint.
The Panduit Opticom 2 RU Rack Mount Fiber Enclosure has integral fiber management and can hold up to 6 FAPs for a maximum of 144 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.

FRME2

The Panduit Opticom 2 RU Rack Mount Fiber Enclosure has integral fiber management and can hold up to 6 FAPs for a maximum of 144 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.
The Opticom SC fiber adapter panel is OS2 and is loaded with 3 SC duplex fiber optic adapters. The fiber optic adapters are blue with zirconia split sleeves.

FAP3WBUDSCZ

The Opticom SC fiber adapter panel is OS2 and is loaded with 3 SC duplex fiber optic adapters. The fiber optic adapters are blue with zirconia split sleeves.
The Panduit Opticom 4 RU Rack Mount Fiber Enclosure has integral fiber management and features 12 FAP/cassette slots. It can accommodate 12 FAPs for a maximum of 288 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.

FRME4

The Panduit Opticom 4 RU Rack Mount Fiber Enclosure has integral fiber management and features 12 FAP/cassette slots. It can accommodate 12 FAPs for a maximum of 288 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.
The Panduit Opticom 3 RU Rack Mount Fiber Enclosure has integral fiber management and can hold up to 9 FAPs for a maximum of 216 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.

FRME3

The Panduit Opticom 3 RU Rack Mount Fiber Enclosure has integral fiber management and can hold up to 9 FAPs for a maximum of 216 fibers. It ensures network reliability by housing, organizing, managing and protecting fiber optic cable, terminations, splices, connectors and patch cords. It is black powder coated steel.
The Opticom SC fiber adapter panel is OS2 and is loaded with 6 SC duplex fiber optic adapters. The fiber optic adapters are blue with zirconia split sleeves.

FAP6WBUDSCZ

The Opticom SC fiber adapter panel is OS2 and is loaded with 6 SC duplex fiber optic adapters. The fiber optic adapters are blue with zirconia split sleeves.
The Opticom ST fiber adapter panel is OS2 and is loaded with 8 ST simplex fiber optic adapters. The fiber optic adapters are steel bodied and has zirconia split sleeves.

FAP8WSTZ

The Opticom ST fiber adapter panel is OS2 and is loaded with 8 ST simplex fiber optic adapters. The fiber optic adapters are steel bodied and has zirconia split sleeves.
The Opticom ST fiber adapter panel is OS2 and is loaded with 6 ST simplex fiber optic adapters. The fiber optic adapters are steel bodied and has zirconia split sleeves.

FAP6WSTZ

The Opticom ST fiber adapter panel is OS2 and is loaded with 6 ST simplex fiber optic adapters. The fiber optic adapters are steel bodied and has zirconia split sleeves.

Frequently Asked Questions

What are the dimensions of the FMD2 drawer?

The FMD2 drawer measures 19.00"W × 3.48"H × 15.40"D (482.60mm × 88.3mm × 391.2mm).

Is the FMD2 compatible with all Panduit adapter panels?

Yes, the FMD2 works with all Panduit LC, SC, ST, and MPO fiber adapter panels.

What is the height of the FMD2 drawer?

The height of the FMD2 drawer is 3.48 inches (88.3 mm).

What is the depth of the FMD2 drawer?

The depth of the FMD2 drawer is 15.40 inches (391.2 mm).

How many fibers can the FMD2 drawer hold?

The FMD2 drawer can hold up to 96 fibers.

What materials are used in the construction of the drawers?

The drawers are constructed of steel material.

Can the FMD2 be used for both fiber and copper cables?

Yes, the FMD2 is completely modular and can manage both fiber and copper cables.

Does the FMD2 drawer have a removable rear tray cover?

Yes, the FMD2 drawer features a removable rear tray cover for easy access to splices.

What features help with cable management in the FMD2?

The FMD2 has built-in bend radius control clips and a removable top cover for easy access.

What type of installations is the FMD2 suitable for?

The FMD2 is suitable for pre-terminated installations, field termination, and splicing installations.

How to Install the FMD2 Enclosure

This guide provides step-by-step instructions for installing and configuring the FMD2 enclosure for fiber optic cables.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

#10-32 screws, #12-24 screws, Cable ties, Grommets, Adhesive mounts

  1. Mount the enclosure

    Secure the enclosure to the rack using four #12-24 screws. Ensure it is firmly attached and level.

  2. Install the grommet

    Determine the entry point for the fiber cable, remove the knock-out, and install the grommet according to the cutting diagram.

  3. Attach the strain relief bracket

    Position the strain relief bracket near the cable entry point and fasten it using a #10-32 hex nut.

  4. Secure the cable

    Insert the fiber cable through the grommet, strip 1 meter of jacket from the end, and attach the strength member to the #10-32 stud using a hex nut.

  5. Install bend radius brackets

    Slide the bend radius brackets onto the tabs with the slots facing outside and snap them in place.

  6. Terminate the fibers

    Terminate the fiber cables with appropriate connectors and mount each connector in the panel.

  7. Label the enclosure

    Attach the Laser Warning Label and Caution Label in clearly visible locations on the enclosure.

  8. Replace the cover

    Once all fibers are looped around the spools, replace the cover by sliding it forward and securing it with a #10-32 screw.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.