Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*
Overview
- Field termination in ~2 minutes using standard fusion splice machines
- Pre-polished endface eliminates field polishing, reducing installation costs
- Supports 900µm tight-buffered or 250µm loose-tube fiber
- Compatible with OM3, OM4, OM4+ Signature Core, OM5, and OS2 fiber types
- Aqua/grey color-coded assembly for easy identification and compliance with standards
Specifications
Application | Used for initial installation of fiber links, MAC work, or repairs to existing links to minimize downtime. |
Boot Color* | Aqua |
Color | Aqua |
Connection | Fusion Splice |
Fiber Type | OM3/OM4/OM5 |
Insertion Loss | NA |
Standard | exceeds TIA/EIA-568-D.3 requirements;RoHS Compliant;TIA/EIA-604 FOCIS-10 compliant |
Temperature Rating, Maximum | 167 F |
Temperature Rating, Maximum | 75 C |
Temperature Rating, Minimum | 167 F |
Temperature Rating, Minimum | 75 C |
Type | Fiber Optic Connector |
Package Dimensions (L x W x H) | 12 IN x 6 IN x 1.5 IN |
Package Weight (Imperial) | 0.166 lbs |

FLCSMCXFDB
The OptiCam Keyed LC Fiber Optic Connector is a multimode 50/125?m OM3/OM4/OM5 simplex fiber connector, intended for 900-micron tight-buffered fiber installation. The connector is keyed (Keyed F, Dark Blue) for network security when used with other Keyed LC products. The LC connector has a natural-colored body with a dark blue-colored backbone and aqua 900?m boot.Frequently Asked Questions
When can splice-on connectors be used?
Splice-on connectors can be used for initial fiber link installation, MAC work, or repairs to existing links.
Do these connectors use index-matching gel?
No, these connectors feature factory pre-polished end-faces and do not require index-matching gel.
How long does it take to terminate a connector?
LC and SC splice-on connectors for 250μm and 900μm cable can be terminated in under two minutes per connector.
What is the typical return loss for these connectors?
Singlemode fiber return loss is > 55dB (UPC) or > 65dB (APC). Multimode fiber return loss is > 30dB (UPC).
What is the typical insertion loss for these connectors?
Singlemode fiber has an average insertion loss of 0.15dB (max 0.30dB). Multimode fiber has an average of 0.10dB (max 0.25dB).
What type of ferrule is used in these connectors?
The connectors use a factory polished zirconia ceramic ferrule.
What fiber sizes can these connectors terminate?
These connectors can terminate 250μm coated fiber or 900μm tight buffered fiber.
What fiber types are compatible with these connectors?
The connectors are compatible with 9/125μm Singlemode (OS1/OS2) and 50/125 Multimode (OM2, OM3, OM4) fibers.
What splice units are compatible with these connectors?
These splice-on connectors are compatible with Sumitomo brand splice units.
What is the operating temperature range?
The functional temperature range for these connectors is from -40°C to 75°C.
How to Install the Panduit Fusion-Splice Connectors
This guide provides step-by-step instructions for installing Panduit fusion-splice connectors using compatible splice machines.
Estimated time: 1h
Tools needed:
Screwdriver, Fiber cleaver, Multimeter
Supplies needed:
Fusion splice connectors, Splice protection sleeves, Lint-free wipes, Fiber cleaning solution
- Prepare the splice machine
Follow the initiation steps specific to your splice machine, including powering up, performing arc tests, and ensuring the machine is clean and maintained.
- Strip the fiber
Strip approximately 35mm of buffer and acrylate off the fiber using a fiber stripper. Ensure you do not damage the fiber during this process.
- Cleave the fiber
Cleave the bare fiber to a length of 10mm using a fiber cleaver. If the fiber does not cleave properly, ensure all acrylate coating has been removed.
- Insert the fiber into the splice holder
Place the cleaved fiber into the left-side fiber holder of the splice machine according to the specific instructions for your machine.
- Prepare the connector assembly
Open the connector assembly blister pack from right to left, ensuring to grab the handling stick rather than the fiber stub end.
- Position the connector assembly
Place the connector assembly into the disposable plastic holder with the fiber stub protruding to the left and the handling stick to the right.
- Close the splice holder
Close the holder on the right side of the splice area, ensuring the field fiber and stub fiber are about 1mm apart.
- Start the splice process
Close the wind cover of the splice stage. Depending on the machine, the splice process may start automatically or require pressing a start button.
- Complete the splice
After the splice is completed, the machine will provide an estimated insertion loss value. Do not touch the fiber or connector assembly until the tension test is complete.
- Install the splice protection sleeve
Gently slide the splice protection sleeve up to the rear of the fiber holder, then open both holders.
- Secure the splice
Grasp the fiber with your left hand and raise it slightly to ensure the splice protection sleeve slides flush against the metal part of the connector subassembly.
- Heat the splice
Place the splice point in the heater of the splice machine, ensuring the splice protection sleeve is centered. Close the heater cover and start the heating process.
- Assemble the connector
Once the heating and cooling cycle is complete, remove the assembly from the heating area and snap the front housing together with the rear housing.
- Finalize the installation
For SC connectors, install the outer housing. Ensure the red alignment dot on APC-style connectors faces up when assembling.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.