Panduit FIDT4X4LBL - The FiberRunner 2-Port Spillout is used to route cable into one or two pieces of 1.5 (38mm) inside diameter split corrugated tubing.
Panduit

FIDT4X4LBL

UPC: 613056764378


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Minimum Qty: 5

Multiplier: 1

*Contact for lower quantities*

Overview

The Panduit FiberRunner 2-Port Spillout (SKU: FIDT4X4LBL) is specifically designed for efficient cable management within industrial and data center environments. This component facilitates the organized routing of fiber optic or copper cabling into split corrugated tubing. Its primary function is to transition cables from a larger conduit or pathway into one or two separate sections of 1.5-inch (38mm) inside diameter split corrugated tubing. This ensures a clean and secure termination point, preventing cable damage and maintaining signal integrity. The FiberRunner system, to which this spillout belongs, is recognized for its ability to provide a structured and scalable pathway for cabling infrastructure. The 1.5-inch (38mm) tubing compatibility makes it suitable for managing bundles of cables that require this specific diameter for protection and organization. Manufactured in the US, this spillout is a key component for maintaining a well-organized and maintainable cabling system. Its design simplifies the process of branching cables into smaller, manageable segments, crucial for complex network deployments where cable segregation and protection are paramount. The split corrugated tubing offers flexibility and ease of access for future cable additions or modifications, while the spillout ensures a secure connection to this tubing.
  • Routes cable into 1.5" (38mm) inside diameter split corrugated tubing
  • Supports one or two pieces of 1.5" tubing
  • Part of the Panduit FiberRunner system for structured cabling
  • Ensures organized and protected cable entry
  • Manufactured in the USA

Specifications

Application
Data Centers and Telco Central Offices
Application
For use with FRVT4X4L** and FRVT6X4L**
Height
3.6 in
Height
91.44 mm
Length
4.24 in
Length
107.696 mm
Material
Polycarbonate/ABS
Standard
RoHS Compliant, UL Listed to 2024 Optical Fiber Cable Routing Assemblies Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3
Type
2-Port Spillout
Width
4.23 in
Width
107.442 mm
Package Dimensions (L x W x H)
7.15 IN x 5.45 IN x 4.9 IN
Package Weight (Imperial)
0.435 lbs
The FiberRunner 2-Port Spillout is used with a 4x4 fitting. The spillout is used to route cable into two separate 1.5 inch (3.8mm) diameter split corrugated tubing.

FRIDT4X4LYL

The FiberRunner 2-Port Spillout is used with a 4x4 fitting. The spillout is used to route cable into two separate 1.5 inch (3.8mm) diameter split corrugated tubing.
PVC Coated Cable Tray Conduit Clamp, Conduit Size 3/4 Inch, Gray

LCC2-G

PVC Coated Cable Tray Conduit Clamp, Conduit Size 3/4 Inch, Gray

Frequently Asked Questions

What is the FiberRunner 4x4 system designed for?

The FiberRunner 4x4 routing system segregates, routes, and protects fiber optic and high performance copper cabling.

What is the FIDT4X4LBL component?

The FIDT4X4LBL is a 2-port spillout designed for 1.5 inches I.D. corrugated tubing.

Where can the FiberRunner 4x4 system be used?

It is suited for data centers, Telco Central Offices, and can be deployed over racks or in approved underfloor applications.

What approvals does the FiberRunner system have?

The FiberRunner 4x4 routing system is UL Listed to 2024 Optical Fiber Cable Routing Assemblies.

What is the flammability rating of the system?

The FiberRunner 4x4 routing system has a flammability rating of 94V-0.

What materials are used for the FiberRunner system?

The channel is made of Rigid PVC, and the fittings are made of PC/ABS.

What bend radius do FiberRunner fittings maintain?

FiberRunner fittings maintain a minimum 2 inches bend radius to protect against signal loss.

What approvals does the FiberRunner system have?

The FiberRunner 4x4 routing system is UL Listed to 2024 Optical Fiber Cable Routing Assemblies.

What bend radius do FiberRunner fittings maintain?

FiberRunner fittings maintain a minimum 2 inches bend radius to protect against signal loss.

Where can the FiberRunner 4x4 system be used?

It is suited for data centers, Telco Central Offices, and can be deployed over racks or in approved underfloor applications.

How to Install the FIDT4X4LBL Fiber Runner

This guide provides step-by-step instructions for installing the FIDT4X4LBL Fiber Runner, ensuring proper mounting and wiring for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the Fiber Runner

    Secure the FIDT4X4LBL to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the ends of the wires. Connect the wires to the appropriate terminals on the FIDT4X4LBL, ensuring a secure fit.

  3. Verify connections

    Use a multimeter to check the continuity of the connections. Ensure there are no shorts or open circuits before powering on the device.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.