Authorized Panduit Distributor
Panduit FHSZA-12-03P - 12F OM4 HD FLEX SC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS, ULTRA IL
Panduit

FHSZA-12-03P

UPC: 613056793491


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Overview

The Panduit FHSZA-12-03P is a 12-fiber OM4 HD FLEX SC splice cassette pre-loaded with discrete pigtails, designed for high-density fiber optic applications. This cassette ensures ultra-low insertion loss (IL) and superior performance in data centers, enterprise networks, and telecommunications infrastructure. Its compact, modular design simplifies cable management and reduces installation time while maintaining high reliability. The OM4 fiber grade supports 10Gbps to 100Gbps Ethernet applications, making it ideal for high-speed data transmission. The HD FLEX SC connectors provide excellent durability and ease of use, while the pre-loaded pigtails eliminate the need for field termination, improving efficiency and reducing errors. The cassette is part of Panduit's high-density fiber optic solution, compatible with their HD Fiber Enclosure 1U 144F systems. It features a low-loss design optimized for OM4 multimode fiber, ensuring consistent performance in demanding environments. The discrete pigtails are factory-terminated for precision and reliability, reducing on-site labor and potential errors. This product is manufactured in the US and meets industry standards for fiber optic splicing and connectivity.
  • 12-fiber OM4 multimode fiber cassette with ultra-low insertion loss
  • Pre-loaded with discrete SC pigtails for quick, error-free installation
  • HD FLEX SC connectors for high durability and ease of use
  • Compact, modular design for high-density fiber optic applications
  • Compatible with Panduit HD Fiber Enclosure 1U 144F systems

Specifications

Color
Black
Connection Type
SC Connector
Connector 1 Type*
SC Duplex
Connector 2 Type*
Unterminated
Fiber Type
OM4
Insertion Loss
0.1 dB
Material
Plastic
Material
Polycarbonate
Mounting Type
Modular Cassette
Series
FHSZA
Type
Fiber Cassette
Package Dimensions (L x W x H)
9 IN x 9 IN x 1 IN
Package Weight (Imperial)
0.81 lbs
12F OM4 HD FLEX SC SPLICE CASSETTE LOADED WITH RIBBON PIGTAILS, ULTRA IL

FHSZA-12-03R

12F OM4 HD FLEX SC SPLICE CASSETTE LOADED WITH RIBBON PIGTAILS, ULTRA IL
12F OS2 HD FLEX SC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS

FHS9N-12-03P

12F OS2 HD FLEX SC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS
24F OS2 HD FLEX LC/APC SPLICE CASSETTE LOADED WITH RIBBON PIGTAILS

FHS9N-24-LAR

24F OS2 HD FLEX LC/APC SPLICE CASSETTE LOADED WITH RIBBON PIGTAILS
OPTICOM 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

FC29N-12-LAAS

OPTICOM 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY
OPTICOM 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; MODIFIED METHOD A - PAIR FLIPPED

FC29N-12-LAAF

OPTICOM 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; MODIFIED METHOD A - PAIR FLIPPED
12F OS2 HD FLEX SC/APC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS

FHS9N-12-3AP

12F OS2 HD FLEX SC/APC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS
24F OM4 HD FLEX LC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS, ULTRA IL

FHSZA-24-10P

24F OM4 HD FLEX LC SPLICE CASSETTE LOADED WITH DISCRETE PIGTAILS, ULTRA IL
OPTICOM 2 MPO TO 12 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

FC29N-24-LAAS

OPTICOM 2 MPO TO 12 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

Frequently Asked Questions

What fiber types do HD Flex cassettes support?

HD Flex Fiber Optic Cassettes support multimode fiber types OM3, OM4, and OM4+ Sig Core, as well as singlemode fiber type OS2.

What are the operating temperature limits for these cassettes?

The operating temperature range for HD Flex Fiber Optic Cassettes is 0°C to 70°C (32°F to 158°F).

What front and rear connectors are available?

Front connectivity options include LC, LC/APC Duplex, SC, SC/APC Duplex, and MPO Adapters. Rear connectivity uses MPO Adapters or 12/24-fiber for splicing.

What is the connector durability of the cassettes?

The connectors meet ANSI/TIA-586C.3 and have a durability of 500 mating cycles.

What are the insertion loss values for multimode cassettes?

Multimode optimized cassettes have 0.5dB insertion loss, while ultra low loss versions have 0.35dB. Splice cassettes have 0.15dB or 0.10dB plus splice loss.

What are the insertion loss values for singlemode cassettes?

Singlemode standard cassettes have 0.75dB insertion loss, and the 24F MPO cassette has 1.2dB. Splice cassettes have 0.35dB plus splice loss.

What return loss can be expected for LC and LC/APC connectors?

Multimode LC connectors have >26dB return loss. Singlemode LC connectors have >55dB, and LC/APC connectors have >65dB.

What networks do HD Flex Fiber Optic Cassettes support?

HD Flex Fiber Optic Cassettes offer deployment options to support both Ethernet and Fibre Channel networks.

What configurations are available for HD Flex cassettes?

Cassettes are available in 4-port, 6-port, and 12-port configurations. Splice cassettes and adapter/coupler modules are also offered.

What standards do these fiber optic cassettes meet?

The cassettes meet or exceed ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5 (FOCIS-5), TIA-604-10 (FOCIS-10), and are RoHS Compliant.

How to Install the FHSZA-12-03P Fiber Splice Cassette

This guide provides step-by-step instructions for installing and configuring the FHSZA-12-03P Fiber Splice Cassette, ensuring proper fiber management and connection.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Pan-Ty Cable Ties, Splice sleeves

  1. Remove the cover

    Press down on the cover removal latch and slide the cover back to remove it from the base.

  2. Prepare the incoming cable

    Strip the outer jacket of the incoming field cable by 20 inches. Secure the cable using Pan-Ty Cable Ties and optionally use a screw for the Aramid Yarn strain relief.

  3. Expose and splice fibers

    Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber, then splice all fibers and heat the splice sleeves according to the splicer manufacturer's instructions.

  4. Route fibers into the cassette

    Route the spliced fibers into the cassette, ensuring they are located under the routing tabs. Secure the splice sleeves in the splice sleeve holders, stacking up to two splice sleeves under each holder.

  5. Reinstall the cover

    Slide the cover forward onto the base to reinstall it securely.

  6. Label the cassette

    Use the label targets provided on the splice only cassette to apply labels for identification, accommodating labels up to 3.25 inches long and 0.35 inches tall.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.