Contact for Pricing
Overview
- Securely manages ingress and egress fiber optic cables.
- Provides essential cable strain relief to prevent damage.
- Enhances signal integrity and reduces network downtime.
- Designed for compatibility with Panduit FlexCore series.
- Facilitates scalability and simplifies maintenance.
Specifications
Application | Cable Management |
Color | Black |
Depth | 2.63386 In. |
Type | Ingress Egress Kit |
Width | 2.000001 In. |
Package Dimensions (L x W x H) | 9 IN x 7.5 IN x 3.75 IN |
Package Weight (Imperial) | 0.926 lbs |

SN2RC
N Style and S Style cabinets. (42, 45, 48, or 51) RU cage nut equipment rails for Net-Access N-Type and S-Type Cabinets, sold in pairs. Use the RU per the correct part number. SN2RC (42ru), SN5RC (45ru), SN8RC (48RU) and SN1RC (51ru)Frequently Asked Questions
What type of cassette is FDCZA-24-10ULH?
It is a FlexCore MPO-LC Cassette, designed for connecting LC Duplex to 2 MPO12 connectors.
How many fibers does the FDCZA-24-10ULH cassette support?
The FDCZA-24-10ULH cassette supports 24 fibers.
What fiber type does the FDCZA-24-10ULH cassette use?
The FDCZA-24-10ULH cassette uses OM4 fiber type.
What is the insertion loss performance of FDCZA-24-10ULH?
The FDCZA-24-10ULH cassette offers ULTRA IL (Ultra Insertion Loss) performance.
What polarity method does the FDCZA-24-10ULH cassette use?
The FDCZA-24-10ULH cassette uses Universal Polarity.
Is the FDCZA-24-10ULH cassette left-handed or right-handed?
The FDCZA-24-10ULH cassette is a left-hand configuration.
What are the connector types on the FDCZA-24-10ULH cassette?
The FDCZA-24-10ULH cassette features LC Duplex connectors on one side and 2 MPO12 connectors on the other.
Can FlexCore cassettes be field terminated?
Yes, FlexCore cassettes can be either factory or field terminated.
How many 4 RU enclosures can a FlexCore frame hold?
Each FlexCore frame can hold up to eleven 4 RU enclosures.
Are FlexCore frames seismic compliant?
Yes, the robust ODF frame with configuration options meets Telcordia Zone 3 seismic requirements.
How to Install the FDFSPLKITBL for Cable Management
This guide provides step-by-step instructions for installing the FDFSPLKITBL to manage excess slack in fiber optic cables effectively.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Cable ties, Protection tubing
- Prepare the installation area
Ensure that the installation area is clean and free of obstructions. Verify that the maximum cable diameter does not exceed 1.34 inches (34mm).
- Strip the cable outer jacket
Using wire strippers, strip the outer jacket of the fiber optic cable to the specified length, ensuring that any Kevlar or strength members are cut back appropriately.
- Install the FDFSPLKITBL
Mount the FDFSPLKITBL onto the designated plate using the provided #10-32 shoulder screws. Ensure the screws are tightened securely.
- Attach protection tubing
Slide the protection tubing over the bare fibers and secure them in place using cable ties. Ensure that the tubing is installed without flexing the bare fibers.
- Lock down strength members
Lock the strength members into the plate using the provided screws, ensuring they are secured between the plate and base.
- Finalize the installation
Place the cover on the FDFSPLKITBL using plungers and grommets. Ensure that the cover is facing the enclosures for proper alignment.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.