
Contact for Pricing
Overview
- Singlemode (OS2) fiber support for high-bandwidth applications
- 24-fiber capacity: 24 LC Duplex to 2xMPO-12 connectors
- Method A straight-through polarity for predictable signal paths
- Standard insertion loss (IL) for reliable performance
- Left-hand orientation for organized cable management
Specifications
Application | FlexCore ODF/OSF |
Color | Black |
Connection | MPO |
Connection Type | LC Duplex to MPO-12 |
Connector 1 Type* | LC Duplex |
Connector 2 Type* | MPO-12 Male |
Fiber Type | OS2 |
Insertion Loss | 0.75 |
Material | Polycarbonate |
Mounting Type | Front Access ODF |
Standard | ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5, (FOCIS-5), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC compliant, supports IEEE802.3 and ANSI T11.2 (Fiber Channel) |
Type | Fiber Cassette |
Package Dimensions (L x W x H) | 9.9 IN x 13 IN x 1.3 IN |
Package Weight (Imperial) | 0.81 lbs |

FDC9N-24-LAAFLH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC/APC Duplex to 2xMPO-12, Method A Flipped, Standard IL, Left Hand Orientation
FDCZA-24-10ASLH
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Left Hand Orientation
FDSN-24
FlexCore Front Access ODF Fiber Optic Splice Only Cassette, includes ribbon and discrete splice protectors
FDC9N-24-10AFLH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Method A Flipped, Standard IL, Left Hand Orientation
F9UYPZRNNSNF050
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC/APC Cassette, Right side Blunt end, Standard Insertion Loss, No pulling Eye - 50 Feet
FDCSA-24-10ULH
FlexCore Front Access ODF Fiber Optic Cassette, Signature Core (OM4+) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation
FDC9N-24-LAASRH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC/APC Duplex to 2xMPO-12, Method A Straight, Standard IL, Right Hand Orientation
FZUYPXRNNONF050
OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Optimized Insertion Loss, No pulling Eye - 50 FeetFrequently Asked Questions
What is the FDC9N-24-10ASLH product?
The FDC9N-24-10ASLH is a FlexCore MPO-LC Cassette, Method A, Left Hand. It features 24F OS2 LC UPC (Duplex) to 2 x MPO12 with Standard Insertion Loss.
What fiber type and connectors does FDC9N-24-10ASLH use?
This cassette uses 24F OS2 (Singlemode) fiber. It connects LC UPC (Duplex) on the front to 2 x MPO12 on the rear, with standard insertion loss.
Is the FDC9N-24-10ASLH compatible with FlexCore ODFs?
Yes, the FDC9N-24-10ASLH is a FlexCore MPO-LC Cassette designed for use within FlexCore Optical Distribution Frames. It fits into 4 RU enclosures with sliding trays.
How many 24F cassettes can a single FlexCore frame hold?
A single FlexCore frame (600mm) can hold up to 132 of the 24F (LC) cassettes, providing a maximum capacity of 3168 fibers.
What types of cassettes are compatible with FlexCore ODFs?
FlexCore ODFs can accept MPO-LC, LC-Tethered, LC-Splice, and Splice-Through cable cassettes.
What is the maximum fiber capacity of a FlexCore ODF frame?
A single FlexCore frame has a maximum fiber capacity of 3168F. A double frame can accommodate up to 6336F, based on 24F LC cassettes.
What are the dimensions of a single FlexCore ODF frame?
A single 600mm FlexCore frame has a height of 2133mm (2159-2200mm with leveling feet), a width of 1050mm, and a depth of 300mm.
What polarity method does the FDC9N-24-10ASLH cassette use?
The FDC9N-24-10ASLH cassette uses Method A polarity. It is configured as a left-hand unit.
Does the FlexCore ODF system meet seismic requirements?
Yes, the robust ODF frame has configuration options that meet Telcordia Zone 3 seismic requirements.
Are there security options for the FlexCore ODF system?
Yes, the FlexCore ODF offers multi-layer security with lock capability available at both 4 RU enclosure and ODF doors. An Enclosure Locking Kit is also available.
How to Install the FlexCore 4RU Universal Enclosure
This guide provides step-by-step instructions for installing the FlexCore 4RU Universal Enclosure onto a rack, including mounting, wiring, and initial setup.
Estimated time: 1h
Tools needed:
Phillips head screwdriver, Wire strippers, Multimeter
Supplies needed:
#12-24 screws, #10-32 x 1/4” screws, Cable ties, Labels
- Remove the shipping bracket
Unscrew the Phillips head screws on the top and bottom of the enclosure to remove the shipping bracket.
- Mount the enclosure
Position the enclosure mounting brackets between the existing rack screws and attach them using #12-24 screws. Hand tighten the screws to allow for alignment.
- Secure the enclosure
Slide the enclosure onto the mounting brackets and install #10-32 screws through each bracket into the enclosure. Fully tighten all screws to secure the enclosure.
- Install cassettes
Open the enclosure door, slide the tray out to the second stop position, and install the cassettes by lifting them into place. Ensure proper alignment.
- Connect patch cords
Install patch cords into the front of the cassettes from left to right, starting with the bottom tray. Route cables according to the provided guidelines.
- Label the enclosure
Apply the provided labels to the enclosure and trays according to the EIA-606-B labeling standards for easy identification.
- Verify installation
Use a multimeter to check connections and ensure all components are functioning correctly before closing the enclosure.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.