Authorized Panduit Distributor
Panduit F8BNM9LBNSAF200 - FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 200 Feet

Panduit F8BNM9LBNSAF200 FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber…

UPC: 613056871700


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit FlexCore Tethered Fiber Optic Enclosure (SKU: F8BNM9LBNSAF200) delivers a high-density, pre-terminated solution for fiber optic network infrastructure. This 200-foot trunk cable features Singlemode OS2 9/125μm fiber, optimized for long-haul and high-bandwidth applications with superior signal integrity. The enclosure supports 288 individual fibers using rollable ribbon technology, enabling efficient cable management and maximum density in a 4 RU footprint. Each fiber strand is pre-terminated to Duplex LC cassettes with standard insertion loss (0.6dB max for LC, 0.5dB max for LC/APC) and straight-through polarity for straightforward connectivity. The modular cassette design supports OS2, OM3, OM4, and OM5 fiber types, providing flexibility for 10G/40G/100G/200G/400G system migration. Ideal for data centers, SANs, healthcare facilities, and central offices, this enclosure features an integrated front cable management tray for easy patch cord organization. The patented cassette-cable strain relief ensures reliable deployment, while the enclosure meets ISO/IEC 11801 and ANSI/TIA-568.3-D standards. The LSZH jacket provides low smoke zero halogen properties, making it suitable for environments where fire safety is critical. Pre-tested for consistent performance, this solution reduces installation time and cost while maintaining high network integrity.
  • 200-foot pre-terminated trunk cable with Singlemode OS2 9/125μm fiber
  • Supports 288 fibers using rollable ribbon technology in a 4 RU enclosure
  • Left cable entry with Multi-Rated I/O Riser (CMR) and LSZH Euroclass Cca jacket
  • Pre-terminated to Duplex LC cassettes with standard insertion loss (0.6dB max for LC)
  • Modular design supports OS2, OM3, OM4, and OM5 fiber types for 10G-400G migration

Specifications

Connection Type
Duplex LC
Material
LSZH (Low Smoke Zero Halogen)
Separated compartments
NA
Series
FlexCore
Size
200 Feet
Package Dimensions (L x W x H)
30.4 IN x 12.9 IN x 31.1 IN
Package Weight (Imperial)
73.66 lbs
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity

F8BNMMRBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

F8BNMMRBNSAF100

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 150 Feet Through Polarity

F8BNMMRBNSAF150

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 150 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity

F8BNMMRBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity

F8BNMMLBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion, Loss, Straight Through Polarity- 50 Feet

F8BNMMLBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion, Loss, Straight Through Polarity- 50 Feet
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity

F8BNM9RBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

F8BNMMLBNSAF100

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

Frequently Asked Questions

What is the Panduit FDUSP6 product?

The Panduit FDUSP6 is an ODF Spool available as a 6-pack with labels.

What does the FDUSP6 kit include?

The FDUSP6 kit includes six ODF spools and corresponding enclosure door labels for 11 x 4 RU enclosures.

How many FDUSP6 kits are needed for a single FlexCore frame?

One FDUSP6 Spool Kit (x6) is required for a single FlexCore 600mm frame configuration.

How many FDUSP6 kits are needed for a double FlexCore frame?

Two FDUSP6 Spool Kits (x6) are required for a double FlexCore 600mm compact cross connect frame.

What is the primary function of the FDUSP6 Spool Kit?

The FDUSP6 Spool Kit is a component of the FlexCore ODF's tool-free adjustable spool system, designed to optimize pathway space.

How to Install the FlexCore ODF Front Access 288 Fiber Tethered Universal Enclosure

This guide provides step-by-step instructions for installing the FlexCore ODF Front Access 288 Fiber Tethered Universal Enclosure, ensuring proper setup and configuration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Unbox the enclosure

    Carefully open the box and remove the foam to reveal the cable. Avoid cutting the cable while opening.

  2. Remove protective materials

    Take out all strips of Tak-Ty holding the coil of cable together and remove the outer cardboard shell to access the enclosure.

  3. Install the enclosure

    Install the enclosure into the frame using the methods discussed in FS203. Ensure it is securely mounted.

  4. Attach the cable transition

    Connect the cable transition to the correct location on the ingress/egress plates on the vertical cable manager as per FS206, Section 4.

  5. Verify cable slack

    Pull out every tray in the enclosure to ensure there is enough slack for the tray to move without putting extra stress on the fibers.

  6. Complete installation

    If needed, remove any individual cassettes for inspection as explained in FS203. Confirm that all components are properly installed and secured.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.