Panduit E42G07L EL2P MSPO PDU, 100/125 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h…
UPC: 613056916517
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 100/125 amp IEC 60309 3P+N+E 6h inlet rated power input
- 21 C13/C15 outlets and 21 C13/C15/C19/C21 outlets for versatile equipment compatibility
- 3-meter cable for flexible installation in industrial or outdoor environments
- Black finish with durable construction for long-term performance in demanding conditions
- Designed for industrial applications including data centers and manufacturing
Specifications
Color | Black |
Connection Type | IEC 60309 |
Current Rating | 100/125 A |
IP Rating | IP67 |
Material | Plastic/Metal |
Poles | 3P+N+E |
Series | EL2P MSPO PDU |
Package Dimensions (L x W x H) | 78 IN x 10 IN x 5 IN |
Package Dimensions (L x W x H) | 198.12 cm x 25.4 cm x 12.7 cm |
Package Weight (Imperial) | 52.0000 L |
Package Weight (Metric) | 23.5872 kg |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std ILFrequently Asked Questions
What is the inlet rating of the E42G07L PDU?
The inlet is rated for 100A or 125A with an IEC 60309 3P+N+E 6h configuration.
How many outlets does the E42G07L have?
The PDU includes 21 C13/C15 outlets and 21 C13/C15/C19/C21 outlets for a total of 42 outlets.
How to Install a Panduit EL2P PDU
This guide provides step-by-step instructions for qualified personnel to safely install and initially set up a Panduit Rack Power Distribution Unit (PDU) in a datacenter rack or cabinet, including mounting, grounding, and power connection.
Estimated time: 1h
Tools needed:
#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench
Supplies needed:
PDU mounting hardware, Ground bonding cable, Blanking panels
- Prepare for Safe Installation and Optimal Airflow
Before beginning, review all safety information in the manual. Ensure the installation environment is temperature and humidity controlled, indoors, and free of conductive contaminants. Position the PDU to maintain a minimum clearance of 2 to 3 inches from cabinet frames or side panels to prevent blocking exhaust airflow. Seal any unused rack spaces with blanking panels to promote proper front-to-back airflow containment. Ensure all facility circuit breakers are in the OFF position before connecting input power.
- Mount the PDU in the Rack
For vertical (0U) PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket. Secure them using a #2 Phillips screwdriver to a torque of 3.0Nm. For horizontal (1U/2U) PDUs, install cage nuts at the desired U location on both front and rear RETMA rails. Screw the mounting bracket ears into the RETMA rail surfaces. For high-power horizontal PDUs, also screw the mounting brackets on the front into the PDU chassis using a 2.5mm hex key Allen wrench, tightening the socket head screws.
- Ground the PDU
Connect a ground bonding cable from the external earthing screw (typically found on the surface with the outlets) on the PDU chassis to a reliable grounding strip, grounding bus bar, or a known earthed reference terminal in the building. Ensure the conductor size meets national or local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A). This provides supplementary Earth bonding to the rack metalwork.
- (Optional) Rotate the Network Controller
If a specific orientation of the physical ports is desired, use a T10 Torx screwdriver to remove the two retaining screws from the network controller. Carefully disconnect the ribbon cable to prevent damage. Rotate the controller to the desired orientation, then carefully reconnect the ribbon cable, ensuring correct orientation and avoiding pinching. Re-fasten the two screws using the T10 Torx screwdriver, torquing them to 2.2–3.1 lbf-in [0.25–0.35 N-M] to avoid metal deformation.
- Connect the PDU to a Power Source
Ensure the feed circuit breaker for the PDU's power source is in the OFF position. Verify that all individual circuit breakers on the PDU itself are set to the ON position. Connect the PDU's input power cord to an appropriately rated branch circuit, adhering to all local and national electrical codes. Refer to the compliance label on the PDU for input ratings. Finally, turn the feed circuit breaker ON. Allow the operating system to load; the Main Menu will display on the screen when complete.
- (Optional) Configure Dual-Rated PDUs
For dual-rated PDUs, perform an additional Command Line Interface (CLI) configuration step to enable the Web interface to report the correct power capacity. Refer to the "CLI Commands" section in the PDU's User Manual for detailed instructions on this configuration.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.