Contact for Pricing
Overview
- 50 Ampere power capacity
- Twenty-one C13/C15 outlets
- Twenty-one C13/C15/C19/C21 outlets
- CS8365-3M input connector
- Black finish
Specifications
Color | Black |
Current Rating | 50 A |
Frequency Rating, Maximum | 208 V |
Frequency Rating, Minimum | 208 V |
Material | Metal |
Mounting | Vertical |
Nema Rating | CS8365 |
Phase | 3 |
Series | TAA EL2P MS |
Standard | UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7 |
Type | PDU |
Width | 2 in |
Width | 50.8 mm |
Package Dimensions (L x W x H) | 70.08 IN x 3 IN x 3 IN |
Package Dimensions (L x W x H) | 178.0032 cm x 7.62 cm x 7.62 cm |
Package Weight (Imperial) | 28.8800 L |
Package Weight (Metric) | 13.1000 kg |
Frequently Asked Questions
What is the standard warranty for Panduit PDUs?
Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.
What is the maximum operating temperature?
Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.
Do Panduit PDUs feature hot-swappable controllers?
Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.
What network connectivity options are available?
PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.
What can Panduit PDUs monitor in real-time?
Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.
Are Panduit PDUs compatible with Cisco systems?
Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.
Do Panduit PDUs integrate with DCIM solutions?
Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.
What is the maximum daisy chain capacity?
Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.
What is the metering accuracy of Panduit PDUs?
Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.
How are vertical PDUs mounted?
Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.
How to Install and Connect a Panduit EL2P PDU
This guide provides step-by-step instructions for installing and connecting a Panduit Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, including grounding and initial power connection.
Estimated time: 1h
Tools needed:
#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench
Supplies needed:
Ground bonding cable, Cage nuts
- Mount the Panduit PDU in the Rack
Carefully position the PDU in the datacenter rack or cabinet, maintaining a minimum clearance of 2 to 3 inches from adjacent IT equipment to ensure proper airflow. For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket and secure them using a #2 Phillips screwdriver to a torque of 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location on the RETMA rails, then screw the mounting bracket ears into the rail surface. For high power horizontal PDUs, use a 2.5mm hex key Allen wrench to tighten the socket head screws on the front mounting brackets.
- Connect the Ground Bonding Cable
Locate the external ground bonding point on the PDU chassis. Connect a ground bonding cable to this point using the provided screw and star washer. Bond the PDU to a known earthed reference terminal in the building, a grounding strip, or a grounding bus bar within the rack. Ensure the conductor size meets national or local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A). WARNING: HIGH LEAKAGE CURRENT. Ensure a reliable grounded (earthed) connection before connecting power distribution products to AC power to reduce the risk of electric shock.
- Connect PDU to Branch Circuit Power
Before connecting, turn OFF the feed circuit breaker for the branch circuit. Verify that all circuit breakers on the PDU are set to the ON position. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) electrical outlet that provides branch circuit overcurrent protection, adhering to all local and national electrical codes. Once connected, turn ON the feed circuit breaker and allow the PDU's operating system to load until the Main Menu displays on the screen. WARNING: Be sure all circuit breakers are in the off position before connecting input power.
- Adjust Network Controller Orientation (Optional)
If a specific physical orientation for the network controller's ports is desired, use a T10 Torx screwdriver to remove the two retaining screws. Carefully disconnect the ribbon cable to prevent damage, then rotate the controller to the preferred orientation. Reconnect the ribbon cable, ensuring correct orientation and avoiding pinching. Reinstall the screws and torque them to a range of 2.2–3.1 lbf-in [0.25–0.35 N-M] to prevent metal deformation.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.