Authorized Panduit Distributor
Panduit E42D20LTAA - TAA EL2P MI PDU, 60 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+E 9h 60A (IP44)-3M, BLACK
Panduit

E42D20LTAA

UPC: 613056915848


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E42D20LTAA is a TAA-compliant, Enterprise Level 2 Power Distribution Unit (PDU) designed for robust power management in critical infrastructure. This PDU features a high current rating of 60 Amps, ensuring ample power delivery for dense IT environments. It offers a comprehensive outlet configuration, including twenty-one C13/C15 outlets and an additional twenty-one outlets supporting C13/C15/C19/C21 connectors, providing flexibility for a wide range of equipment. Power is supplied via an IEC 60309 3P+E 9h 60A connector, rated for IP44 protection against solid objects and water ingress, suitable for various industrial and data center applications. The unit is finished in black and includes a 3-meter power cord. Manufactured by Panduit, this PDU (SKU: E42D20LTAA) is built to support demanding power distribution needs with reliability and compliance. Its extensive outlet count and high amperage capacity make it an ideal choice for rack-based power distribution where multiple device types require connection. The IP44 rating on the input connector adds an extra layer of protection against environmental factors. This PDU is engineered for efficient power delivery and management within your facility. Its TAA compliance ensures suitability for government and related projects requiring adherence to specific trade agreements.
  • TAA Compliant Enterprise Level 2 PDU
  • 60 Amp High Current Rating
  • 21 x C13/C15 Outlets
  • 21 x C13/C15/C19/C21 Outlets
  • IEC 60309 3P+E 9h 60A (IP44) Input Connector

Specifications

Frequency Rating, Maximum
208 V
Frequency Rating, Minimum
208 V
Material
Metal
Mounting
Vertical
Phase
3
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
30.8600 L
Package Weight (Metric)
13.9981 kg

Frequently Asked Questions

What is the amperage rating of this Panduit PDU?

This Panduit PDU has a current rating of 60 Amps.

How many C13/C15 outlets does the E42D20LTAA have?

The Panduit E42D20LTAA PDU is equipped with twenty-one C13/C15 outlets.

What type of input connector does this PDU use?

This PDU utilizes an IEC 60309 3P+E 9h 60A connector.

Is this Panduit PDU TAA compliant?

Yes, the Panduit E42D20LTAA is a TAA-compliant PDU.

What is the IP rating of the input connector?

The IEC 60309 input connector on this PDU has an IP44 rating.

What additional outlet types are supported by this PDU?

In addition to C13/C15, the PDU supports C19 and C21 outlet types.

How to Install a Panduit EL2P Rack Power Distribution Unit (PDU)

This guide provides step-by-step instructions for qualified personnel to safely install and connect a Panduit EL2P Rack PDU into a datacenter rack or cabinet.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware, Cage nuts, Ground bonding cable, Star washer

  1. Review Safety Information and Prepare for Installation

    Before beginning, thoroughly review all safety information in the PDU installation manual. Ensure that the installation environment is temperature and humidity controlled, free of conductive contaminants, and within 0°C to 60°C (32°F to 140°F). Verify that all circuit breakers are in the off position before connecting input power. Ensure the PDU is positioned to maintain 2-3 inches clearance for airflow and seal unused rack spaces with blanking panels. WARNING: High leakage current exists. Ensure a reliable grounded (earthed) connection before connecting power distribution products to AC power. Installation must be performed by individuals knowledgeable about AC power products.

  2. Mount the PDU in the Rack

    Determine the appropriate mounting method for your PDU (vertical 0U or horizontal 1U/2U). For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket and secure them using a #2 Phillips screwdriver to 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location(s) on both front and rear RETMA rails, then screw the mounting bracket ears into the rail surfaces. For high-power horizontal PDUs, use a 2.5mm hex key Allen wrench to tighten the socket head screws on the front mounting brackets into the PDU chassis. Use only the hardware provided to install the PDU.

  3. Ground the PDU

    Connect a ground bonding cable to the external ground bonding point on the PDU chassis, typically found on the surface with the outlets. Use the provided external earthing screw and star washer for supplementary Earth bonding to the rack metalwork or a known earthed reference terminal in the building. Ensure conductor sizes meet national or local electrical codes (e.g., NEC Table 250.122 for copper conductors). WARNING: For permanently connected PDUs, installation must be performed by a licensed electrician and connected to a protective earth ground.

  4. Connect the PDU to a Power Source

    Ensure the feed circuit breaker for the power source is OFF. Verify that all circuit breakers on the PDU are set to the ON position. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit, adhering to all local and national electrical codes. Ensure the power cord has sufficient length. After connecting, turn the feed circuit breaker ON and wait for the operating system to load and the Main Menu to display on the screen. WARNING: Connect only to a circuit providing branch circuit overcurrent protection of appropriate current rating. Do not overload the PDU; total input current of connected equipment cannot exceed the PDU's total output rating.

  5. Configure Dual Rated PDUs (Optional)

    If you have a dual-rated PDU, refer to the CLI Commands in the User Manual for an additional configuration step required to enable the Web interface to report the correct power capacity.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.