Authorized Panduit Distributor
Panduit E36G18LTAA - TAA EL2P MSPO PDU, 30 AMP, (18)C13/C15, (18)C13/C15/C19/C21, NEMA L6-30P-3M, BLACK

Panduit E36G18LTAA TAA EL2P MSPO PDU, 30 AMP, (18)C13/C15, (18)C13/C15/C19/C21, NEMA L6-30P-3M, BLACK

UPC: 613056915985


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit TAA EL2P MSPO PDU (SKU: E36G18LTAA) is a 30 Amp vertical power distribution unit designed for data centers and IT environments. It features 36 total outlets: eighteen IEC C13/C15 outlets and eighteen IEC C13/C15/C19/C21 outlets, providing compatibility with standard servers, network switches, and higher-power devices. The PDU includes three 20A double-pole breakers for circuit protection and uses a NEMA L6-30P 30 Amp, 250 Volt locking plug for secure power input. Constructed in a 0U vertical orientation, this black (RAL 9005) unit measures 9.2 inches in depth and weighs approximately 118.1 lbs. Ideal for mission-critical IT infrastructure, this PDU supports efficient power distribution with derated input current of 24A.
  • 36 total outlets: 18x C13/C15 and 18x C13/C15/C19/C21 for versatile equipment compatibility
  • Three 20A double-pole breakers for circuit protection and load management
  • NEMA L6-30P 30 Amp, 250V locking plug for secure power input
  • 0U vertical design, 9.2" depth, black (RAL 9005) with 10 AWG SJT cord

Specifications

Frequency Rating, Maximum
208 V
Frequency Rating, Minimum
208 V
Material
Metal
Mounting
Vertical
Phase
1
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
19.8400 L
Package Weight (Metric)
8.9994 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
CIMP-M-04xRJ45

0602000104-00

CIMP-M-04xRJ45
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, with an option to extend it to 5 years.

What is the maximum operating temperature for Panduit PDUs?

Panduit PDUs are built to withstand high operating temperatures up to 140°F (60°C) at full load.

Are Panduit intelligent PDUs compatible with Cisco Nexus Dashboard?

Yes, Panduit's intelligent PDUs seamlessly integrate with Cisco Nexus Dashboard software to enhance energy savings and sustainability insights.

Do Panduit PDUs feature hot-swappable controllers?

Yes, many Panduit PDUs feature hot-swappable controllers, allowing removal of the network interface module without affecting outlet status.

What types of monitoring do Panduit PDUs provide?

Panduit PDUs offer real-time monitoring of power, environmental conditions, and cabinet security, with options for input and outlet level monitoring.

Can Panduit PDUs be mounted without tools?

Yes, vertical Panduit PDUs can be mounted effortlessly into a rack using tool-less installation with convenient button slots.

What is the power capacity range for Universal PDUs?

Panduit's Universal PDUs support power requirements from 3.3kW to 27.6kW, adaptable by simply swapping the input cord.

What types of outlets are available on Panduit PDUs?

Panduit PDUs offer various outlet types including C13, C19, NEMA 5-20R, and combination outlets that can be used as C21, C19, C15, or C13.

What is the metering accuracy of Panduit PDUs?

Metering accuracy for Panduit PDUs is typically ± 2%, with some EL2P models offering a higher accuracy of ± 0.5%.

Can environmental conditions be monitored with Panduit PDUs?

Yes, Panduit PDUs can integrate with environmental sensors for real-time monitoring of temperature, humidity, and leak detection.

How to Install a Panduit EL2P PDU

This guide provides step-by-step instructions for qualified personnel to install a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and power connection.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware (screws, cage nuts), Ground bonding cable

  1. Prepare and Mount Vertical PDU

    Ensure proper airflow by maintaining 2-3 inches clearance around the PDU and sealing unused rack spaces with blanking panels. Install the vertical PDU by inserting its pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket. Secure the PDU using a #2 Phillips screwdriver, tightening to a recommended torque of 3.0Nm. Orient outlets towards the center of the rack.

  2. Mount Horizontal PDU (Optional)

    If installing a horizontal (1U or 2U) PDU, first install cage nuts at the desired U location on the rack's front and rear equipment rails. Screw the PDU's mounting bracket ears into the RETMA rail surface. For high power units, use a 2.5mm hex key Allen wrench to secure the front mounting brackets to the PDU chassis, tightening the socket head screws.

  3. Ground the PDU

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis (typically near the outlets) to a grounding strip or bus bar in the rack, or to a known earthed reference terminal. Ensure conductor sizes meet national or local electrical codes. This supplementary Earth bonding is essential to reduce the risk of electric shock due to high leakage currents.

  4. Connect PDU to Power Source

    WARNING: Ensure the feed circuit breaker is OFF and all PDU circuit breakers are ON before connecting. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit outlet that is easily accessible. Verify the PDU's input ratings on the compliance label. Do not overload the PDU. Once connected, turn the feed circuit breaker ON and wait for the operating system to load. TO ISOLATE THIS EQUIPMENT, DISCONNECT THE POWER CORD.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.