Panduit E24E32L EL2P MS PDU, 60 (48) AMP, (12)C13/C15, (12)C13/C15/C19/C21, IEC 60309 3P+E 9h 60A…
UPC: 613056920446
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 60 Amp capacity for high-power applications
- 24x IEC C13/C15 outlets for standard equipment
- 12x mixed C13/C15/C19/C21 outlets for versatile connectivity
- IEC 60309 3P+E 9h 60A plug for industrial power input
- IP44 rated for protection against dust and splashing water
Specifications
Phase | 3-Phase |
Phase | 3 |
Standard | Nemko Listed Certificate: NA202011186, CE, UKCA, ROHS, REACH, China ROHS |
Type | PDU |
Package Dimensions (L x W x H) | 68 IN x 11 IN x 6 IN |
Package Dimensions (L x W x H) | 172.72 cm x 27.94 cm x 15.24 cm |
Package Weight (Imperial) | 32.0000 L |
Package Weight (Metric) | 14.5152 kg |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std ILFrequently Asked Questions
What is the total amperage rating of this Panduit PDU?
The Panduit EL2P MS PDU has a total amperage rating of 60 Amps.
How many C13/C15 outlets does the E24E32L PDU offer?
The E24E32L PDU offers 24 IEC C13/C15 outlets.
What types of outlets are included in the mixed outlet configuration?
The mixed outlet configuration includes C13, C15, C19, and C21 outlet types.
What is the input plug type for this Panduit power distribution unit?
The input plug type is an IEC 60309 3P+E 9h 60A plug.
What is the IP rating of the EL2P MS PDU?
The EL2P MS PDU has an IP44 rating, providing protection against dust and splashing water.
How to Install a Panduit EL2P Rack Power Distribution Unit (PDU)
A comprehensive guide for qualified personnel to safely install and connect a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, including mounting, grounding, and initial power-up. Always follow local and national electrical codes.
Estimated time: 1h
Tools needed:
#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench
Supplies needed:
Mounting hardware (screws, brackets), Cage nuts, Ground bonding cable
- Mount the PDU in the Rack
Before starting, ensure you are qualified personnel and aware of all safety precautions regarding lethal voltages and high leakage currents. For vertical PDUs, verify or adjust pre-installed mounting buttons, then insert them into the keyhole slots on the rack's PDU mounting bracket. Secure with a #2 Phillips screwdriver to 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location on both front and rear RETMA rails (for high power models). Screw mounting bracket ears into the RETMA rail surface. For high power models, secure front mounting brackets to the PDU chassis using a 2.5mm hex key Allen wrench. Ensure 2-3 inches clearance between PDU chassis and cabinet frame to avoid blocking airflow, and seal unused rack spaces with blanking panels.
- Ground the PDU
Locate the external ground bonding point on the PDU chassis. Connect a ground bonding cable from this point to the rack metalwork, a grounding strip, or a known earthed reference terminal in the building. Ensure the conductor size meets all national and local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A). This step is critical to reduce the risk of electric shock due to high leakage currents and must be performed by qualified personnel.
- Connect the PDU to a Power Source
WARNING: Ensure the feed circuit breaker for the branch circuit is in the OFF position before connecting power. Verify that the devices connected to the PDU are compatible with the line voltage supplying the PDU. Ensure all circuit breakers on the PDU are set to the ON position. Connect the PDU's input power cord to an appropriately rated, grounded branch circuit, adhering to all local and national electrical codes. Turn the feed circuit breaker ON. Wait for the PDU's operating system to load; the Main Menu will display on the screen upon completion.
- Rotate or Replace the Network Controller (Optional)
If desired, rotate or replace the network controller. Use a T10 Torx screwdriver to remove the two retaining screws. If rotating, disconnect the ribbon cable, carefully rotate the controller to the desired orientation, and then reconnect the ribbon cable, ensuring no crimping or pinching. If replacing, disconnect the ribbon cable from the existing controller, connect it to the new controller, and carefully mate the new controller to the PDU chassis. Re-install the two screws and torque them to 2.2–3.1 lbf-in [0.25–0.35 N-M] using a T10 Torx screwdriver, avoiding overtightening.
- Configure Dual-Rated PDUs (Optional)
For dual-rated PDUs, perform an additional Command Line Interface (CLI) configuration step to enable the Web interface to report the correct power capacity. Refer to the PDU's User Manual for specific CLI commands and instructions to complete this configuration.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.