Panduit DIRLC9606RB1 - The air inlet duct has been designed in collaboration with Cisco for use with the Cisco Catalyst 9606R switch. The duct geometry optimizes thermal performance of the switch by channeling the air from the lower front inlet duct to the upper rear exhaust port of the duct.
Panduit

DIRLC9606RB1

UPC: 613056785908


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Panduit DIRLC9606RB1 air inlet duct is a precision-engineered thermal management accessory designed in collaboration with Cisco for the Cisco Catalyst 9606R switch. This duct channels airflow from the lower front inlet to the upper rear exhaust port, optimizing thermal performance and preventing overheating in high-density network environments. The geometry ensures efficient air circulation, reducing fan load and extending hardware lifespan. Compatible exclusively with the Cisco Catalyst 9606R, this duct integrates seamlessly with the switch's existing airflow design, maintaining compliance with Cisco's thermal specifications. Manufactured in Sweden under Panduit's quality standards, the DIRLC9606RB1 is a critical component for data centers, enterprise networks, and industrial deployments requiring reliable thermal management. No additional power or configuration is required; the duct installs directly onto the switch chassis.
  • Precision-engineered duct for Cisco Catalyst 9606R switch
  • Channels airflow from lower front inlet to upper rear exhaust port
  • Optimizes thermal performance and prevents overheating
  • Manufactured in Sweden under Panduit quality standards
  • No additional power or configuration required

Specifications

Mounting Type
Direct mount onto switch chassis
Package Dimensions (L x W x H)
30 IN x 17.5 IN x 16.13 IN
Package Weight (Imperial)
36 lbs
2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Intermediate Spacer For Use With Nonmetallic Ducts

S289JLN

2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Intermediate Spacer For Use With Nonmetallic Ducts
2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Base Spacer For Use With Nonmetallic Ducts

S288JLN

2 x 3 Inches Duct Spacer, High Impact Polystyrene Snap-Loc Base Spacer For Use With Nonmetallic Ducts

Frequently Asked Questions

What switch is the DIRLC9606RB1 duct compatible with?

The DIRLC9606RB1 duct is designed exclusively for use with the Cisco Catalyst 9606R switch platform.

What are the overall dimensions of the duct assembly?

The overall dimensions are 15.87 inches D x 19.00 inches W x 29.71 inches H, or 22.60 inches D when factoring in the side bracket extension arms.

What material is the DIRLC9606RB1 duct made from?

The duct is made from steel with a durable Black polyester epoxy powder coat finish.

What is the product weight of the duct assembly?

The product weight of the DIRLC9606RB1 duct assembly is 36.0 lb. (16.4kg).

What is the primary purpose of the DIRLC9606RB1 duct?

The duct optimizes the thermal performance of the Cisco Catalyst 9606R switch by channeling cool air to maintain its operating temperature range.

What rack types are compatible with this duct assembly?

The 90° switch orientation design allows for installation in standard 19-inch 4-post racks and cabinets.

Are the duct's dimensions adjustable?

Yes, the side bracket extension arms offer an adjustable range of ±25mm, affecting the depth dimension.

What items are included with the DIRLC9606RB1 duct?

It includes inlet and exhaust duct assemblies, side support brackets, extension arms, adjustable bracket sets, air filter brackets, a hardware kit, and installation instructions.

Does the duct assembly offer cable management features?

Yes, it features integrated D-ring cable management for neat cable dressing and easier connections.

How does the duct improve energy efficiency?

By providing a path for cool air to the switch, the duct allows data center temperature set points to be raised, increasing energy efficiency and lowering operating costs.

How to Install the DIRLC9606RB1 Duct System

This guide provides step-by-step instructions for installing the DIRLC9606RB1 Duct System, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Cage nuts, Bonding cage nuts

  1. Prepare the installation space

    Ensure that there is 17RU of open space available for the installation of the switch, bottom inlet duct, and top exhaust duct.

  2. Install the vertical mounting brackets

    Rotate the Cisco 9606R switch 90 degrees counterclockwise. Use M4 x 12mm pan head screws and lock washers to attach the vertical mounting brackets securely.

  3. Install the bonding cage nuts

    Install four #12-24 bonding cage nuts in the designated locations labeled 'A' to ensure proper grounding.

  4. Mount the chassis into the rack

    Align the bottom hole of the vertical mounting bracket with the top hole of the rack unit and secure the chassis in place.

  5. Install the inlet and exhaust ducts

    Install the inlet duct directly underneath the chassis and the exhaust duct directly above the chassis to complete the duct system setup.

  6. Install cable managers

    Insert the cable managers into the keyholes and push downward to lock them into place for organized cable management.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.