Panduit CFAPPBL1A - The Opticom angled fiber patch panel is used with FMT1A and FMT2A trays and holds up to four Opticom Cassettes or FAP adapter panels. It is compatible with all 19 wide EIA rack mount installations, is black powder coated steel, and fits in a 1 RU footprint.

Panduit CFAPPBL1A The Opticom angled fiber patch panel is used with FMT1A and FMT2A trays and holds up to…

UPC: 074983008780


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Minimum Qty: 5

Multiplier: 1

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit Opticom CFAPPBL1A is a 1 RU angled fiber patch panel for 19-inch EIA rack mount installations. Constructed from black powder-coated steel, it supports up to four Opticom Cassettes or FAP adapter panels, ensuring structured fiber termination. Designed for compatibility with Panduit FMT1A and FMT2A trays, it streamlines deployment in network infrastructure. The angled design maintains fiber bend radius, preserving signal integrity in high-density environments. Its 1 RU footprint optimizes rack space, making it suitable for data centers, telecom rooms, and enterprise network closets. The steel construction and powder coating ensure durability and a professional finish. Key features include a front cover that protects fibers when closed and provides space for port mapping labels when open. Cable routing flanges on both sides ensure smooth transitions and bend radius control. The panel accommodates Panduit pre-terminated cassettes, FAPs, trunk cables, connectors, and patch cords. With the FLEX-OPTI-1RU adapter bracket, it also supports HD Flex Cassettes. The rear mounting design eliminates the need for horizontal cable managers, conserving floor space. Fiber management spools enhance protection, maintenance, and cable slack management for an aesthetic appearance. The CFAPPBL1A is part of a modular system for managing up to 96 fibers. It mounts on a standard EIA 19-inch rack, reducing floor space requirements and lowering system costs. The FQCRCML Rear Cable Manager, designed for standard EIA 19-inch racks, supports MPO Interconnect Cables terminated into Opticom and HD Flex Cassettes, providing strain relief, bend radius control, superior aesthetics, organization, and routing.
  • 1 RU angled fiber patch panel for 19-inch EIA rack mount installations
  • Holds up to four Opticom Cassettes or FAP adapter panels
  • Compatible with Panduit FMT1A and FMT2A trays for structured fiber management
  • Angled design manages fiber bend radius to maintain signal integrity
  • Black powder-coated steel construction for durability and professional finish

Specifications

Application
Provide a flexible and modular system for managing fiber termination, connections, and patching for all applications and offer the industry s highest patch field density and fiber counts for all fiber
Application
Provide a flexible and modular system for managing fiber termination, connections, and patching for all applications and offer the industry’s highest patch field density and fiber counts for all fiber
Color
Black
Depth
4.16 In.
Material
Metal
Mounting
DIN Rail
Slot Capacity
4
Standard
RoHS Compliant
Type
Front Loading Adapter Panel
Width
19 In.
Package Dimensions (L x W x H)
19.9 IN x 3.3 IN x 6.5 IN
Package Weight (Imperial)
1.49 lbs
The Opticom angled fiber patch panel is used with FMT1A and FMT2A trays and holds up to eight Opticom Cassettes or FAP adapter panels. It is compatible with all 19 wide EIA rack mount installations, is black powder coated steel, and fits in a 2 RU footprint.

CFAPPBL2A

The Opticom angled fiber patch panel is used with FMT1A and FMT2A trays and holds up to eight Opticom Cassettes or FAP adapter panels. It is compatible with all 19 wide EIA rack mount installations, is black powder coated steel, and fits in a 2 RU footprint.
The IndustrialNet Cat 6 UTP bulkhead RJ45 coupler module with protective cap is ideal in manufacturing environments. The bulkhead provides an IP67 rated seal that provides protection from dust and temporary immersion in water.

IAEBHC6

The IndustrialNet Cat 6 UTP bulkhead RJ45 coupler module with protective cap is ideal in manufacturing environments. The bulkhead provides an IP67 rated seal that provides protection from dust and temporary immersion in water.
The threaded boot is intended for use with multimode OM1 OptiCam connectors being installed on jacketed fiber optic cable that is from 1.6mm to 2.0mm in diameter. The boot is electric ivory, and comes in a pack of 10.

FMCBT2EI-X

The threaded boot is intended for use with multimode OM1 OptiCam connectors being installed on jacketed fiber optic cable that is from 1.6mm to 2.0mm in diameter. The boot is electric ivory, and comes in a pack of 10.
The threaded boot is intended for use with multimode OM1 OptiCam connectors being installed on jacketed fiber optic cable that is 3.0mm in diameter. The boot is electric ivory, and comes in a pack of 10.

FMCBT3EI-X

The threaded boot is intended for use with multimode OM1 OptiCam connectors being installed on jacketed fiber optic cable that is 3.0mm in diameter. The boot is electric ivory, and comes in a pack of 10.
The NetKey Faceplate accepts four keystone modules. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate can be identified with an adhesive label, and is black.

NK4FNBL

The NetKey Faceplate accepts four keystone modules. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate can be identified with an adhesive label, and is black.
The NetKey Adapter accepts two keystone modules, mounts to a standard GFCI faceplate, and is international white.

NK2RMFIW

The NetKey Adapter accepts two keystone modules, mounts to a standard GFCI faceplate, and is international white.
The NetKey Faceplate accepts one keystone module. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate includes a label pocket for easy identification and is white.

NK1FWHY

The NetKey Faceplate accepts one keystone module. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate includes a label pocket for easy identification and is white.
The NetKey Adapter accepts two keystone modules, mounts to a standard GFCI faceplate, and is international gray.

NK2RMFIG

The NetKey Adapter accepts two keystone modules, mounts to a standard GFCI faceplate, and is international gray.

Frequently Asked Questions

What types of fiber optic adapters are included?

The fiber adapter panels include horizontal MPO adapters, LC, Shuttered LC, keyed LC, and SC fiber optic adapters.

How do I install the fiber adapter panels?

Fiber adapter panels snap quickly into the front of fiber optic patch panels and enclosures for easy installation.

What standards do the fiber adapters meet?

All adapters meet or exceed TIA/EIA-568-C.3 requirements and various TIA/EIA-604 FOCIS standards.

Are the adapter housing colors standardized?

Yes, LC and SC adapter housing colors follow the TIA/EIA-568-C.3 suggested color identification scheme.

What is the material of the split sleeves?

The split sleeves are made of zirconia ceramic for OM1/OM4/OM5 multimode adapters and OS2 singlemode adapters.

What is the insertion loss performance?

The fiber adapter panels support the performance of connectors and patch cords, ensuring low insertion loss.

What are the available rack mount options?

Rack mount options include 1 RU, 2 RU, and 4 RU enclosures that hold various numbers of fiber adapter panels.

What is the purpose of blank fiber adapter panels?

Blank fiber adapter panels reserve space for future use in fiber adapter panel installations.

Can I customize the installation for fiber and copper cables?

Yes, multimedia modular panels allow customization for integrating fiber optic and copper cables.

What types of polarity configurations are available?

Type A polarity features a key-up to key-down configuration, while Type B polarity has a key-up to key-up configuration.

How to Install the CFAPPBL1A Angled Patch Panel

This guide provides step-by-step instructions for installing and configuring the CFAPPBL1A Angled Patch Panel, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

#10-32 x 5/16" screws, #10-32 hex nuts, #12-24 x 1/2" screws, M6 x 1 screws, #10 flat washers, Cable entry grommet, Strain relief bracket, Adhesive bevel entry clips, Adhesive backed mounts, TAK-TYs, Slack spools

  1. Mount the enclosure

    Secure the enclosure to the rack using four #12-24 x 1/2" screws. If mounting to a metric rack, use M6 x 1 screws instead.

  2. Install the strain relief bracket

    Position the strain relief bracket near the cable entry point and secure it with one #10-32 x 5/16" screw and one #10-32 hex nut.

  3. Prepare and install the cable entry grommet

    Determine the size of the innerduct to be used and cut the grommet accordingly. Install the grommet into the enclosure and secure it with one #10 flat washer and one #10-32 hex nut.

  4. Route the fiber cables

    Route the fiber cables through the cable entry grommet to the fiber cassettes, ensuring to use TAK-TYs to secure the fiber cords at the cable entry location and other points.

  5. Install fiber adapter panels

    Insert the fiber adapter panels into the angled patch panel and secure them using the NyLatch fasteners.

  6. Connect and secure the strength member

    Route the strength member of the cable around the #10-32 stud and secure it with the previously installed #10 flat washer and #10-32 hex nut.

  7. Final checks and calibration

    Verify all connections and ensure that the fiber cables are properly secured and not under excessive tension. Perform any necessary calibration as per the manufacturer's guidelines.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.