Panduit C2SDT9W06DAW1 The Net-Contain Sliding Door Frame Adapter works with cabinet-supported cold aisle and…
UPC: 613056172739
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Facilitates cabinet-supported cold/hot aisle containment
- Designed for 6-foot (1800mm) aisles
- Compatible with 48 or 51 RU tall cabinets
- White finish for a clean aesthetic
- Enhances data center thermal management
Specifications
Color | White |
Depth | 3.44 In. |
Material | Steel |
Standard | RoHS Compliant |
Type | Cabinet Door Frame Adapter |
Width | 84.86 in |
Width | 2155.444 mm |
Package Dimensions (L x W x H) | 102 IN x 30 IN x 6 IN |
Package Weight (Imperial) | 96.1 lbs |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
CUSTOMDIN
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What is required to install the door adapter kit?
Drilling into the floor would be required to install the door adapter kit.
What heights are available for adjustable EOR vertical walls?
Adjustable EOR vertical wall panels are available in 16" – 26" H, 26" – 38" H, and 38" – 66" H. They are for 912mm – 960mm/1000mm/1208mm – 1266mm aisle widths.
What heights are available for adjustable vertical walls?
Adjustable vertical wall panels are available in 16" – 26" H, 26" – 38" H, and 38" – 66" H. These fit 600mm, 700mm, and 800mm wide Net-Access™ N-Type and S-Type Cabinets.
What are the dimensions of the End of Row Sliding Doors?
The End of Row Sliding Doors (CUD1SD*, CUD2SD*) are 2134 mm H x 1422 mm W. They are designed for a 4' (1200mm) aisle width.
What Panduit products are compatible with this system?
The system is compatible with Net-Access™ N-Type and S-Type Cabinets, FiberRunner®, and Wyr-Grid® Overhead Cable Routing Systems.
What heat loads can the system manage?
The system can address heat loads up to 20kW per cabinet. This enables dense server applications and eliminates data center hot spots.
Does the Net-Contain system have moving parts?
No, the Net-Contain system is a passive system with no moving parts. This design contributes to energy efficiency and improved system reliability.
What is the Net-Contain system's primary function?
The Net-Contain Passive Hot Aisle Containment System segregates cold and hot air streams by exhausting hot air between cabinet rows. It aims to capture all cabinet exhaust air and return it to cooling units.
Does the Net-Contain system have moving parts?
No, the Net-Contain system is a passive system with no moving parts. This design contributes to energy efficiency and improved system reliability.
What is required to install the door adapter kit?
Drilling into the floor would be required to install the door adapter kit.
How to Install the C2SDT9W06DAW1 Net-Contain Aisle Containment System
Step-by-step guide for installing Panduit Net-Contain aisle containment systems, including wall panels, door adapters, doors, and ceiling structures.
Estimated time: 3h
Tools needed:
Screwdriver, Bubble level, Laser or string line, Drill, Torx driver
Supplies needed:
Mounting screws, Cage nuts, Floor tiles, Foam seals, M5x0.8 12mm button head torx screws, M6 Flange Hex Nuts, M6 x 1 x 70mm Hex Head Bolts, M5 x 0.8 x 10 Hex Head Screws, M6 x 1 x 10 Hex Head Screws, M6x12mm hex head bolts, M6 nuts, 1/4-14 x 1 Self Drilling Screws
- Position and Level Cabinets
Position the first cabinet in the desired location, aligning its front with the cold aisle floor tile. Use a bubble level on the vertical rails to ensure the cabinet is level. Adjust legs as needed. Ensure adjacent cabinets are at the same height and parallel. Place subsequent cabinets 1-2 inches from the previous one, level them, align their tops, and move them flush with the preceding cabinet. Repeat for all cabinets in the row. For opposing rows, maintain a spacing of 72.0" ± 0.5" (1800mm ± 13mm) between cabinet edges. Ensure all cabinets within a row are leveled to within ± 6mm (0.25").
- Install Wall Panels
Begin by installing a Wall Panel at the far right end of the cabinet row (when facing the front). Align the Wall Panel with the threaded holes on top of the cabinet. Secure the Wall Panel using two M5x0.8 12mm button head torx screws. Trim two pieces of Foam Seal to fit the Wall Panel and attach one piece of 25mm x 25mm Foam Seal to the end of each Wall Panel. Apply a Foam Seal Strip along the edge of the installed Wall Panel to seal the gap between adjacent panels. Slide the next Wall Panel over until it is centered and the foam is compressed. Repeat for all cabinets in the row. Note: Wall Panel Covers are installed at the end of Section 4.
- Prepare for Door Adapter Installation
If using S-Type cabinets, knock out the square hole with a screwdriver and remove the tab. Insert a cage nut into the opening and rotate it 45 degrees with a screwdriver to secure. For N-Type cabinets, this step is not required. Drill up to twelve 8mm (5/16") clearance holes through the floor tiles in the locations shown for attaching the Door Adapter feet. A minimum of two screws per foot is required when securing the feet to the floor.
- Attach Door Adapter Components
Attach the feet to the floor using M6 Flange Hex Nuts and M6 x 1 x 70mm Hex Head Bolts, with a minimum of two screws per foot. Attach the Aisle Beam, centering it between the Wall Beams. Secure with M6 Flange Hex Nuts. Attach Cabinet Brackets to the cabinets using M6 Flange Hex Nuts and M6 x 1 x 10 Hex Head Screws (for N-Type) or M5 x 0.8 x 10 Hex Head Screws (for S-Type). Attach Foam Seals in the approximate locations indicated. Attach the Transom, centering it between the Wall Beams. For 42RU or 48RU cabinets, attach the Transom directly. For 45RU or 51RU cabinets, assemble the Transom to the Transom Extender first, ensuring the flange hooks around the underside of the Extender for 45RU. Secure the Transom assembly with M6 Flange Hex Nuts. Attach the Blanking Panels using M6 Flange Hex Nuts, leaving them loose initially.
- Install Doors and Ceiling Structure
Install the Dual Door onto the Door Adapter Frame using (8) 1/4-14 Self Drilling Screws. For the ceiling structure, install the initial Aisle Beam into the Wall Panels one cabinet in from the end of each POD, centering it and securing with M6x12mm hex head bolts and M6 nuts. Repeat for the other end of the row. Use a laser or string line to set a base line for alignment. Install additional Aisle Beams, aligning their cut-outs to the baseline and securing them with M6x12mm hex head bolts and M6 nuts. Ensure Aisle Beams are spaced appropriately. Install Ceiling Panel Stops between each set of aisle beams, leaving them loose, and slide them to the full back position. Install Ceiling Support Brackets in alignment with holes in the Aisle Beams, adjusting width if needed, and secure with M6 x 12mm hex head bolts and M6 nuts. Secure the Support Bracket to the Door Adapters at each end. Finally, install the Ceiling Panels by sliding them under the hold-down on the Aisle Beam, sliding the Ceiling Panel Stop under the panel, tightening its hardware, loosening screws under the Ceiling Support Bracket, sliding the hold-down over the panel, and tightening the screws.
- Install Wall Panel Covers
Using two M5 pan head screws, attach one Wall Panel Cover to each Wall Panel.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.