Authorized Hammond Power Distributor
Hammond Power TE3A0440KKM - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 440kVA 480D-480Y/277 V CU 60Hz 3R

Hammond Power TE3A0440KKM 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive…

UPC: 803423145064


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power TE3A0440KKM is a 440kVA, three-phase, drive isolation transformer designed for energy efficiency, meeting DOE2016 and NRCan 2019 compliance standards. This transformer operates with a primary voltage of 480D and a secondary voltage of 480Y/277V, at a frequency of 60Hz. It features a robust copper winding (CU) for reliable performance and is housed in a 3R enclosure, suitable for various industrial environments. Engineered for drive isolation, this unit effectively separates motor drives from the power source, mitigating harmonic distortion and protecting sensitive equipment. Its compliance with stringent energy efficiency regulations ensures reduced operational costs and a smaller environmental footprint. The 600V class rating signifies its capability to handle significant voltage levels safely and effectively. Ideal for applications requiring clean power delivery to variable frequency drives (VFDs) and other motor control systems, the TE3A0440KKM from Hammond Power provides a dependable and compliant power solution. Manufactured in the USA, this transformer offers quality and reliability for critical industrial power distribution needs.
  • 440kVA, Three-Phase Drive Isolation Transformer
  • 480D Primary Voltage / 480Y/277V Secondary Voltage
  • DOE2016 and NRCan 2019 Energy Efficiency Compliant
  • 600V Class, 60Hz Frequency
  • 3R Enclosure, Copper Winding (CU)

Specifications

Application
Variable Speed Drives.
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH6-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
64 IN
Height
1625.6 mm
Insulation Class
220 Deg C Class
KVA Rating
440 kVA
Length
41.5 in
Length
1054.1 mm
Mounting
Floor Mount
Mounting Method
Floor
NEMA Frame Size
Type 3R
Number Of Phases
3
Phase
3PH
Primary Voltage
480D V
Secondary Voltage
480Y/277 V
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
440kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Wall Mounting
No
Warranty
10 year warranty
Weight
3000 L
Width
49 in
Width
1244.6 mm
Winding
Copper
Package Dimensions (L x W x H)
41.5 IN x 49 IN x 64 IN
Package Dimensions (L x W x H)
105.41 cm x 124.46 cm x 162.56 cm
Package Weight (Imperial)
3000.000 L
Package Weight (Metric)
1360.800 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 440kVA 460D-460Y/266V CU 60Hz 3R

TE3A0440JJM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 440kVA 460D-460Y/266V CU 60Hz 3R
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1008G33

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 480D-480Y/277 V CU 60Hz 3R

TE3A0550KKM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 480D-480Y/277 V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 460D-460Y/266V CU 60Hz 3R

TE3A0660JJM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 460D-460Y/266V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 575D-575Y/332V AL 60Hz 3R

TE3A0145NN

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 575D-575Y/332V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 575D-575Y/332V AL 60Hz 3R

TE3A0660NN

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 575D-575Y/332V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V CU 60Hz 3R

TE3A0027JCM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V CU 60Hz 3R

Frequently Asked Questions

What is the insulation system and temperature rise for this transformer?

The transformer features a 220°C insulation system with a standard 150°C temperature rise, with optional 115°C and 80°C rises available.

What is the standard enclosure type for the HPS Tribune E transformer?

The HPS Tribune E transformer comes with a standard heavy-duty ventilated Type 3R enclosure, suitable for indoor or outdoor use.

What is the BIL rating for HPS Drive Isolation Transformers?

All HPS Drive Isolation Transformers have a standard 10kV BIL rating for increased reliability and protection against voltage spikes.

What mounting options are available for the HPS Tribune E transformer?

The transformer supports both floor mounting and wall/ceiling mounting. Integral brackets are standard up to 45kVA for faster installation.

What is the warranty period for HPS Tribune E transformers?

HPS offers a 10-year warranty on the Tribune E series transformers.

What conductor materials are used in the HPS Tribune E transformers?

The HPS Tribune E transformers are available with either copper or aluminum conductors.

What safety certifications does this transformer hold?

The HPS Drive Isolation Transformers are UL Listed (File: E112313) and CSA Certified (File: LR3902).

What are the typical impedance values for this transformer series?

The typical impedance for the HPS Tribune E series ranges from 1.8% to 7.5%.

What is the frequency rating for the HPS Tribune E transformers?

The standard frequency rating is 60 Hz, with optional 50/60 Hz availability.

What is the K-Rating for this transformer series?

The kVA sizing allows for motor efficiency and 6 Pulse Drive Harmonics with a K-Rating of K=13.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.