Overview

Hammond Power TE3A0660JJM is a 600V class three-phase drive isolation transformer designed for compliance with DOE2016 and NRCan 2019 energy efficiency standards. Rated at 660kVA, this transformer delivers 460V delta primary to 460V wye secondary with a 266V center tap, operating at 60Hz. The 3R-rated enclosure ensures protection against environmental conditions, making it suitable for industrial and commercial applications requiring reliable power conditioning. With a copper winding configuration, this transformer provides high efficiency and low harmonic distortion, critical for variable frequency drive (VFD) systems. Ideal for facilities prioritizing energy savings without compromising performance, the TE3A0660JJM meets stringent regulatory requirements while delivering consistent power quality. Specifications include a primary voltage of 460V delta and secondary voltage of 460Y/266V, optimized for three-phase systems. The transformer’s design supports compliance with North American energy efficiency mandates, reducing operational costs while maintaining operational integrity in demanding environments.
  • 660kVA three-phase drive isolation transformer
  • DOE2016 and NRCan 2019 energy efficiency compliant
  • 460V delta primary to 460V wye secondary with 266V center tap
  • Copper winding for high efficiency and low harmonic distortion
  • 3R-rated enclosure for environmental protection

Specifications

Application
Variable Speed Drives.
Connection Type
460D-460Y/266V
Current Rating
660 kVA
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH6-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
64 IN
Insulation Class
220 Deg C Class
Ip Rating
3R
KVA Rating
660 kVA
Length
41.5 IN
Material
CU
Mounting
Floor Mount
Mounting Method
Floor
NEMA Frame Size
Type 3R
NEMA Rating
3R
Number Of Phases
3
Phase
3PH
Poles
3P
Primary Voltage
460D
Secondary Voltage
460Y/266V
Series
TE3A
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
660kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Voltage Rating
600 VAC
Wall Mounting
No
Warranty
10 year warranty
Weight
3600 L
Width
49 IN
Winding
Copper
Package Dimensions (L x W x H)
41.5 IN x 49 IN x 64 IN
Package Dimensions (L x W x H)
105.41 cm x 124.46 cm x 162.56 cm
Package Weight (Imperial)
3600.000 L
Package Weight (Metric)
1632.960 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 460D-460Y/266V CU 60Hz 3R

TE3A0550JJM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 460D-460Y/266V CU 60Hz 3R
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1008G33

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 575D-575Y/332V AL 60Hz 3R

TE3A0145NN

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 575D-575Y/332V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 575D-575Y/332V AL 60Hz 3R

TE3A0660NN

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 575D-575Y/332V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V CU 60Hz 3R

TE3A0027JCM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-230Y/133 V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V CU 60Hz 3R

TE3A0330KKM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 330kVA 480D-480Y/277 V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 575D-380Y/220V CU 60Hz 3R

TE3A0034NGM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 34kVA 575D-380Y/220V CU 60Hz 3R

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.