The Hammond Power TE3A0027JCM is a 600V class three-phase drive isolation transformer compliant with DOE2016 and NRCan 2019 energy efficiency standards. Rated at 27kVA, this transformer features a 460V delta primary and 230V wye/133V secondary, optimized for industrial motor drive applications. Constructed with copper windings, it delivers low losses and high reliability, reducing operational costs while maintaining performance. The transformer operates at 60Hz, aligning with standard industrial power systems, and includes harmonic mitigation for cleaner power delivery. With a 3R enclosure rating, it protects against dust and water ingress, suitable for indoor or sheltered outdoor installations. UL-listed and manufactured in the US, the TE3A0027JCM is built for harsh industrial environments where voltage regulation and efficiency are critical. Ideal for facilities requiring DOE2016 and NRCan 2019 compliance, this transformer ensures long-term durability and energy savings in demanding applications.
  • DOE2016 and NRCan 2019 compliant energy-efficient design
  • 27kVA rating with 460V delta primary and 230V wye/133V secondary
  • Copper-wound construction for low losses and high reliability
  • 3R enclosure rating for dust and water ingress protection
  • UL-listed, manufactured in the US for industrial environments

Specifications

Application
Variable Speed Drives.
Connection Type
460D-230Y/133V
Connection Type
Delta-Wye
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH2-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60Hz
Frequency
60 Hz
Frequency Rating
60 HZ
Height
28.8 in
Insulation Class
220 Deg C Class
KVA Rating
27 KVA
Length
23.8 IN
Material
Copper
Mounting
Floor or Wall mount
Mounting Method
Wall and Floor
NEMA Frame Size
Type 3R
NEMA Rating
3R
Number Of Phases
3
Phase
3PH
Poles
3
Primary Voltage
460D
Secondary Voltage
230Y/133 V
Series
TE3A
Size
27kVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
27kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Voltage Rating
460D-230Y/133 V
Voltage Rating
460D-230Y/133 VAC
Voltage Rating
460V delta primary / 230V wye secondary / 133V secondary
Voltage Rating
460V delta primary / 230V wye secondary (133V)
Voltage Rating
460V delta primary / 230V wye secondary / 133V
Wall Mounting
Yes
Warranty
10 year warranty
Weight
310 L
Width
25.8 IN
Winding
Copper
Package Dimensions (L x W x H)
23.8 IN x 25.8 IN x 28.8 IN
Package Dimensions (L x W x H)
60.452 cm x 65.532 cm x 73.152 cm
Package Weight (Imperial)
310.000 L
Package Weight (Metric)
140.616 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-460Y/266V CU 60Hz 3R

TE3A0027JJM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 27kVA 460D-460Y/266V CU 60Hz 3R
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1004G63

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H118S

Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What are the key features of this transformer?

This transformer features a Type 3R enclosure, 220°C insulation system, standard 10kV BIL rating, and is suitable for indoor or outdoor applications. It offers increased reliability and protection against voltage spikes.

What temperature rise options are available?

The transformer offers temperature rise options of 80°C, 115°C, and 150°C, with 150°C being the default setting. All units utilize a 220°C insulation system.

What mounting options are available?

The transformer supports floor and wall/ceiling mounting. Integral floor and wall mounting brackets are standard up to 45kVA, allowing for faster installation.

What conductor materials can be used?

The transformer can be wound with either copper or aluminum conductors, which are precision wound and electrically balanced to minimize axial forces during short-circuit conditions.

What are the standard electrical specifications?

The transformer operates at 60 Hz, has a standard 10kV BIL rating, and supports K-rating for motor efficiency and 6 Pulse Drive Harmonics (K=13).

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.