Hammond Power CP1K6G0019CC Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type…
UPC: 803423190071
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
- It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
- HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
- Typical Power Factor: >95%
- Includes a contactor for simplified integration
Specifications
Ambient Operating Temperature | 0 to 40 Deg C |
Application | For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants |
Cooling | Natural Convection |
Depth | 20.1 IN |
Enclosure | Type 3R DH1 |
Enclosure Type | Type 3R |
Frequency | 60Hz |
Frequency Rating | 60 HZ |
Height | 22 IN |
Impedance | 19A |
Input Current | 17 A |
Length | 20.1 in |
Mounting | Wall/Ceiling/Floor Mount |
Mounting Style | Floor |
Output Current | 19 A |
Special Features | Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements. |
Standard | cUL Listed (E61431) |
Voltage | 480 V |
Voltage Rating | 480V |
Warranty | 3 Years |
Weight | 150 L |
Width | 21.5 IN |
Package Dimensions (L x W x H) | 20.1 IN x 21.5 IN x 22 IN |
Package Dimensions (L x W x H) | 510 mm x 546 mm x 559 mm |
Package Weight (Imperial) | 150.000 L |
Package Weight (Metric) | 68.000 kg |

CP1K6G0019C
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R
CP1K6G0632CC
Passive Harmonic Filters, 500 HorsePower, 480 Volts, 632 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0073CC
Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0120CC
Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0059CC
Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0096CC
Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
CP1P6G0020FC
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Open Style, ContactorFrequently Asked Questions
What is the primary function of the HPS passive harmonic filter?
The HPS passive harmonic filter improves power quality by reducing harmonic current distortion and improving true power factor.
How much harmonic current distortion does the filter typically reduce?
It reduces total harmonic current distortion by 80%, typically to 5% or less at full load.
What standard does the HPS passive harmonic filter meet?
It meets IEEE 519 harmonic requirements when operated within designed parameters.
What types of non-linear loads is this filter designed for?
The filter is designed to mitigate harmonics created by non-linear loads such as variable frequency drives (VFDs) and other three-phase rectifiers.
What is the typical power factor correction achieved by the filter?
The filter corrects true power factor to over 95%.
What are the available voltage ratings for this filter?
The filter is available in 480VAC or 600VAC voltage ratings, with a +/-10% tolerance.
Is the filter compatible with generator-fed systems?
Yes, its low kVAr ratings ensure compatibility with generator-fed systems without leading power factor issues at light loads.
What is the warranty period for the HPS passive harmonic filter?
The filter comes with a 3-year warranty.
What enclosure types are available for the passive harmonic filter?
The filter is available in an open enclosure type or a Type 3R enclosure.
What is the efficiency of the HPS passive harmonic filter at full load?
The filter has an efficiency of no less than 99% at full load.
How to Install the HPS Centurion P Passive Harmonic Filter
This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter, Forklift or hoisting equipment
Supplies needed:
Mounting screws, Terminal connectors, Grounding wire
- Inspect the filter
Immediately after receiving the filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is noted, file a claim with the carrier.
- Mount the filter
Using a forklift or hoisting equipment, securely position the HPS Centurion P Passive Harmonic Filter in the designated installation location, ensuring it is level and has sufficient clearance for ventilation.
- Ground the filter
Connect the designated main grounding location of the filter to a proper ground. Ensure all ground connections are tight and secure before proceeding.
- Make electrical connections
Connect the input terminals A1, B1, and C1 to the corresponding phases of the power supply. Connect the output terminals A2, B2, and C2 to the load. Ensure all connections are made in accordance with the nameplate diagram.
- Verify connections
Use a multimeter to verify that all electrical connections are secure and that there is no voltage present before energizing the filter.
- Energize the filter
Once all connections are verified, turn on the power supply to the filter and check for proper operation. Listen for any unusual noises and monitor for any warning indicators.
- Perform initial testing
Use a power quality analyzer to measure total harmonic voltage distortion, total harmonic current distortion, and power factor before and after connecting the filter to establish a baseline for performance.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.