Hammond Power CP1P6G0059CC - Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1P6G0059CC

UPC: 803423190583


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1P6G0059CC is a passive harmonic filter designed to mitigate harmonic distortion in industrial electrical systems. This unit is rated for 60 HorsePower (HP), 59 Amperes (A), and operates at 600 Volts (V) with a frequency of 60 Hertz (Hz). Its advanced HPS design significantly reduces harmonic current distortion, typically achieving an 80% reduction, bringing distortion levels to 5% or less at full load. This performance ensures compliance with IEEE 519 harmonic requirements when operated within its designed parameters. Beyond harmonic reduction, the filter also corrects the true power factor to over 95%, contributing to improved system efficiency and reduced energy costs. The enclosure is rated Type 3R, providing protection against falling rain and sleet, making it suitable for outdoor or exposed industrial environments. This filter includes a contactor for integrated control and operation. Manufactured by Hammond Power, this passive harmonic filter (SKU: CP1P6G0059CC) is a reliable solution for applications requiring clean power and efficient operation. Its robust construction and precise engineering make it a valuable component for motor control centers, variable frequency drive (VFD) systems, and other inductive loads prone to harmonic generation.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/exposed environments
  • Integrated contactor for control
  • Reduces harmonic distortion by up to 80%
  • Corrects true power factor to over 95%
  • Meets IEEE 519 harmonic requirements

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
14.8 IN
Enclosure
Type 3R DH3
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
25.2 IN
Impedance
59A
Input Current
55 A
Length
27 IN
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
Output Current
59 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600V
Warranty
3 Years
Weight
275 L
Width
11.3 IN
Package Dimensions (L x W x H)
14.8 IN x 11.3 IN x 25.2 IN
Package Dimensions (L x W x H)
376 mm x 287 mm x 648 mm
Package Weight (Imperial)
275.000 L
Package Weight (Metric)
125.000 kg
Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0073CC

Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
DigiBOX B-30 ND RS 240V STEEL

USDBP01ND0

DigiBOX B-30 ND RS 240V STEEL

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift (if necessary)

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Position the HPS Centurion P Passive Harmonic Filter on a stable surface or mount it on a wall using the provided brackets. Ensure there is adequate clearance for ventilation and maintenance.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a suitable ground. Ensure that all grounding connections are secure before proceeding.

  4. Make electrical connections

    Connect the input terminals A1, B1, and C1 to the phases A, B, and C of the power supply. Connect the output terminals A2, B2, and C2 to the corresponding phases of the load. Refer to the nameplate for specific wiring instructions.

  5. Verify connections

    Use a multimeter to check that all connections are secure and that there are no shorts. Ensure that the input voltage is within 5% of the nameplate voltage before energizing the unit.

  6. Energize the filter

    Once all connections are verified, turn on the power supply to the HPS Centurion P Passive Harmonic Filter. Monitor for any unusual noises or indicators of malfunction.

  7. Perform initial testing

    Use a power quality analyzer to measure total harmonic distortion and power factor before and after connecting the filter to ensure it is functioning correctly.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.