The Hammond Power Solutions (HPS) CD1X0045F is an open-style dV/dT filter designed for critical applications involving Variable Frequency Drives (VFDs) and motors, particularly when extended cable lengths are utilized. This filter is engineered to mitigate the damaging effects of high-frequency voltage spikes and rapid voltage rise (dV/dT) that can occur over longer motor leads, thereby protecting motor insulation and extending motor lifespan. With a robust current rating of 45 amperes and an operating voltage capacity of up to 600 volts, the CD1X0045F is suitable for a wide range of industrial motor control systems. Its open-style construction allows for efficient heat dissipation and straightforward integration into existing control panels. By reducing peak voltages and smoothing the output waveform from the VFD, this dV/dT filter significantly lowers the stress on motor windings, preventing premature failure and reducing maintenance costs. The UNSPSC code for this product is 83101808, and it is manufactured in France. When longer cable runs are a necessity for motor placement or system design, the HPS dV/dT filter CD1X0045F provides essential protection and ensures reliable motor operation.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Mitigates damaging dV/dT voltage spikes
  • Protects motor insulation and extends motor lifespan

Specifications

Altitude
<1000 m
Ambient Operating Temperature
-25C to 40C (suitable to 50C) Deg C
Application
Designed for applications with long cables between the VFD and the motor
Connection Type
Series
Connection Type
Screw Terminal/DIN Rail
Connection Type
Screw Terminal
Cooling
Natural Convection
Current Rating
45 A
Enclosure
Open Frame
Height
7.25 in
Inverter Operating Frequency
up to 60Hz
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Inverter Switching Frequency
2kHz - 4kHz
Length
6 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
Mounting Type
Open Style/DIN Rail/Panel Surface
Mounting Type
DIN rail or panel surface
NEC 480 HP
30
NEC 600 HP
40
Peak Voltage
at Motor: 150% of DC bus voltage
Poles
3
Poles
3-Phase
Series
CD1X
Special Features
Peak Voltage at Motor: 150% of DC bus voltage
Standard
cUL
System Voltage
up to 600V
Voltage Rating
600 V
Voltage Rating
600 VAC
Voltage Rating
up to 600V
Watts Loss
235
Weight
14 lbs
Width
8 in
Package Dimensions (L x W x H)
6 IN x 8 IN x 7.25 IN
Package Dimensions (L x W x H)
152.4 mm x 203.2 mm x 184.15 mm
Package Weight (Imperial)
14.000 L
Package Weight (Metric)
6.200 kg
dV/dT filter 35 amperes up to 600 volts open style

CD1X0035F

dV/dT filter 35 amperes up to 600 volts open style
dV/dT filter 54 amperes up to 600 volts open style

CD1X0054F

dV/dT filter 54 amperes up to 600 volts open style
dV/dT filter 27 amperes up to 600 volts open style

CD1X0027F

dV/dT filter 27 amperes up to 600 volts open style
dV/dT filter 45 amperes up to 600 volts type 1

CD1X0045E

dV/dT filter 45 amperes up to 600 volts type 1
dV/dT filter 22 amperes up to 600 volts open style

CD1X0022F

dV/dT filter 22 amperes up to 600 volts open style
dV/dT filter 65 amperes up to 600 volts open style

CD1X0065F

dV/dT filter 65 amperes up to 600 volts open style
dV/dT filter 17 amperes up to 600 volts open style

CD1X0017F

dV/dT filter 17 amperes up to 600 volts open style
dV/dT filter 54 amperes up to 600 volts type 1

CD1X0054E

dV/dT filter 54 amperes up to 600 volts type 1
dV/dT filter 35 amperes up to 600 volts type 1

CD1X0035E

dV/dT filter 35 amperes up to 600 volts type 1
dV/dT filter 80 amperes up to 600 volts open style

CD1X0080F

dV/dT filter 80 amperes up to 600 volts open style
dV/dT filter 108 amperes up to 600 volts open style

CD1X0108F

dV/dT filter 108 amperes up to 600 volts open style
dV/dT filter 27 amperes up to 600 volts type 1

CD1X0027E

dV/dT filter 27 amperes up to 600 volts type 1

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the dV/dT filter

    Examine the dV/dT filter for any transit damage and ensure all parts are included as per the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Securely mount the dV/dT filter in a dry area using the provided mounting screws. Ensure it is positioned for adequate ventilation and accessibility.

  3. Connect the wiring

    Connect the filter terminals A1, B1, and C1 to the corresponding phases U, V, and W on the output of the variable frequency drive. Connect terminals A2, B2, and C2 to T1, T2, and T3 of the motor. Ensure all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before proceeding.

  5. Verify connections

    Use a multimeter to check that all electrical connections are correct and that there is no voltage present before energizing the unit.

  6. Energize the filter

    Once all connections are verified and secure, replace all covers and doors, then turn on the power supply to the dV/dT filter.

  7. Perform initial checks

    After energizing, check for any unusual sounds or signs of overheating. Monitor the filter's operation to ensure it is functioning correctly.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.