Hammond Power CD1X0012F - dV/dT filter 12 amperes up to 600 volts open style
More images

Hammond Power CD1X0012F dV/dT filter 12 amperes up to 600 volts open style

UPC: 803423168100


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CD1X0012F dV/dT filter is an open-style reactor designed for industrial motor protection in variable frequency drive (VFD) applications. Rated for 12 amperes and 600 volts AC, this three-phase iron core filter mitigates voltage spikes and reduces motor winding insulation stress caused by high-frequency switching in VFDs. The differential mode inductance is implemented via a three-phase reactor with a single core and three coils, featuring terminal blocks or copper pads marked A1, B1, C1, A2, B2, and C2. The winding supports 150% RMS overload for 60 seconds once every 10 minutes, ensuring resilience under transient conditions. Designed for operation up to 60Hz at 600V (90Hz with de-rating), the filter accommodates VFD carrier frequencies up to 4kHz and supports motor cable lengths up to 1000 feet. With an ambient temperature rating of 50°C, it is suitable for demanding industrial environments. The open-style construction enables efficient heat dissipation and straightforward panel integration. This filter is essential for extending motor insulation and bearing life, reducing maintenance costs, and preventing premature motor failure in VFD-driven systems.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Rated for 150% RMS overload for 60 seconds (once every 10 minutes)
  • Open-style construction for efficient heat dissipation and panel integration

Specifications

Altitude
<1000 m
Ambient Operating Temperature
-25C to 40C (suitable to 50C) Deg C
Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
12 A
Enclosure
Open Frame
Height
5.5 in
Inverter Operating Frequency
up to 60Hz
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Inverter Switching Frequency
2kHz - 4kHz
Length
6 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
Mounting Type
Open Style
NEC 480 HP
7.5
NEC 600 HP
10
Peak Voltage
at Motor: 150% of DC bus voltage
Series
dV/dT Filter
Special Features
Peak Voltage at Motor: 150% of DC bus voltage
Standard
cUL
System Voltage
up to 600V
Voltage Rating
up to 600V
Voltage Rating
600 V
Watts Loss
180
Weight
6 lbs
Width
8 in
Package Dimensions (L x W x H)
6 IN x 8 IN x 5.5 IN
Package Dimensions (L x W x H)
152.4 mm x 203.2 mm x 139.7 mm
Package Weight (Imperial)
6.000 L
Package Weight (Metric)
2.700 kg
dV/dT filter 9 amperes up to 600 volts open style

CD1X0009F

dV/dT filter 9 amperes up to 600 volts open style
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
dV/dT filter 80 amperes up to 600 volts type 1

CD1X0080E

dV/dT filter 80 amperes up to 600 volts type 1
dV/dT filter 65 amperes up to 600 volts open style

CD1X0065F

dV/dT filter 65 amperes up to 600 volts open style
dV/dT filter 22 amperes up to 600 volts type 1

CD1X0022E

dV/dT filter 22 amperes up to 600 volts type 1
dV/dT filter 54 amperes up to 600 volts open style

CD1X0054F

dV/dT filter 54 amperes up to 600 volts open style
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style

CP1P6G0008F

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style
dV/dT filter 80 amperes up to 600 volts open style

CD1X0080F

dV/dT filter 80 amperes up to 600 volts open style

Frequently Asked Questions

What is the purpose of the HPS Centurion D1 dV/dT filter?

The D1 filter is designed to mitigate both high frequency components and voltage spikes between a VFD and motor, especially with longer cable lengths.

What applications are suitable for the HPS Centurion D1 series dV/dT filters?

These filters are designed for applications with long cables between the VFD and motor, including Oil & Gas Pumps, Wastewater Treatment Plants, HVAC Systems, Pulp & Paper, and Irrigation Fields.

How does a dV/dT filter protect a motor?

It protects the motor by slowing down the rate of voltage increase and minimizing damaging peak voltages that occur within the motor’s windings and along the cables.

What is the system voltage rating for these dV/dT filters?

The system voltage rating is up to 600V, suitable for 480V-600V applications.

What is the current rating range for HPS dV/dT filters?

The current rating ranges from 2A to 108A, with higher ratings available upon consultation with HPS.

What is the maximum recommended motor lead length for this filter?

The maximum recommended motor lead length is 600 ft, though longer lengths may be possible with consultation.

What is the ambient operating temperature range for the dV/dT filter?

The ambient operating temperature range is -25°C to 40°C, suitable up to 50°C.

What is the voltage drop across the HPS Centurion D1 filter?

The voltage drop across the filter is less than 3%.

What are the dimensions of the CD1X0012F model?

The CD1X0012F model has dimensions of 8.00 in width, 6.00 in depth, and 5.50 in height.

What is the insulation system temperature rating for the dV/dT filter?

The insulation system rating is 130°C for models 2A-54A and 180°C for models above 55A.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. Report any damages to the carrier.

  2. Mount the filter

    Secure the dV/dT filter to a suitable mounting surface using the provided mounting screws. Ensure it is level and stable.

  3. Connect the wiring

    Connect the output phases A1, B1, and C1 to the corresponding U, V, and W terminals of the variable frequency drive. Connect A2, B2, and C2 to T1, T2, and T3 of the motor.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify all ground connections are secure before energizing the unit.

  5. Verify connections

    Use a multimeter to check the tightness and clearance of all electrical connections. Ensure there are no loose wires or potential short circuits.

  6. Perform a dry-out if necessary

    If the filter has been exposed to moisture, dry it out using warmed air for at least 24 hours before energizing.

  7. Energize the filter

    Once all connections are verified and the unit is dry, restore power to the dV/dT filter and monitor for proper operation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.