ABB Low Voltage Drives RMBA-01-KIT ModBus is a serial, asynchronous protocol. The ModBus protocol does not specify the…
Alternate Item Number: 64606778
UPC: 662348077191
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Enables connection of ABB Low Voltage Drives to RS-485 Modbus-RTU networks.
- Provides galvanically isolated RS-485 interface for enhanced system reliability.
- Supports common read/write single and multiple register function codes.
- Facilitates integration with Modicon PLCs and other automation devices.
- Designed for universal connectivity, simplifying drive control and management.

DLC400BP
The TORK DLC400BP SunSet 365-Day Astronomic Digital Timer is designed for providing total control over 4 different output channels in indoor or outdoor applications. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to activate lights or signage when the ambient light level drops below a customizable threshold. Features four output channel, different settings for holidays and seasons and a 6-month battery backup. Designed for commercial applications including lighting, HVAC equipment, signage, store windows and security or parking lot lights.
FSO-12-KIT
The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.
2TLA020070R4700
Safety PLC. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus). NOTE: Version 2 hardware/processor.
C6200.0060
FlexGen Generator Controller - Basic. Integrated generator controller. The C6200 provides load depending start and stop, automatic synchronization and active / reactive load sharing for one diesel generator (3 phase). The C6200 will also ensure that the generator is always operating at the nominal speed / frequency no matter the load. Advanced grid paralling and Power Factor function are provided as standard. Programmable inputs and outputs allows for easy integration with PLC control. The C6200 can be operated in either fully automatic mode, semi-automatic mode or in manual mode.
PAC79
Aluminum Type PAC - Aluminum Parallel Groove Clamp with Cast Copper Liner for Wire Range Main: 336.4-1/0, 1/0-6 AR ASCR 400-2/0 Str., 1/0-6 AR AL/CU, Tap: ASCR 1/0 Str.-8 Sol. ALCU, Prefilled with Oxide Inhibitor.Frequently Asked Questions
Which ABB drives support the RCAN-01 CANopen adapter?
The RCAN-01 adapter supports ACS550, ACQ550, ACS800, ACQ800, and DCS800 drives.
What is the RCAN-01 adapter compatible with?
The RCAN-01 adapter is compatible with ACS550, ACQ550, ACS800, ACQ800, and DCS800 drives.
What CANopen standard does the RCAN-01 adapter fulfill?
The RCAN-01 adapter fulfills the CiA (CAN in Automation) standard DSP 402 for Device Profile Drives and Motion Control.
What is the purpose of ABB's protocol network adapters?
These adapters provide universal connectivity to all major controllers and communication networks, allowing users to choose the best network for their needs.
What is the baud rate range for CANopen with RCAN-01?
The baud rate for CANopen with the RCAN-01 ranges from 10 kbit/s to 1 Mbit/s.
How many devices can be connected with RCAN-01?
The RCAN-01 adapter supports a maximum of 127 devices on the network.
What are the benefits of network connectivity for ABB drives?
Network connectivity decreases installation time, reduces downtime, provides more data at lower cost, and allows for remote data access.
What does CANopen device profiles define?
CANopen device profiles define direct access to drive parameters and time-critical process data communication.
What are some end-user benefits of ABB Network Connectivity?
End-user benefits include decreased installation and start-up costs, reduced downtime, increased productivity, and lower maintenance costs.