ABB Low Voltage Drives FSO-12-KIT The FSO 12 safety functions module supports the following functions according to EN/IEC…
Alternate Item Number: 3AXD50000016771
UPC: 662348075678
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
The ABB FSO-12-KIT safety functions module enhances operational safety for low voltage drives by monitoring and executing critical safety functions. Designed for compliance with EN/IEC 61800-5-2:2007, this module supports standard safety functions including Safe Torque Off (STO), Safe Brake Control (SBC), Safe Stop 1 (SS1), and Safely-Limited Speed (SLS). Additionally, it offers advanced safety features such as Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and Prevention of Unexpected Start-up (POUS). The FSO-12-KIT does not operate the drive but ensures it operates within configured safety limits, activating STO if limits are exceeded. Commissioning and configuration require the Drive Composer Pro (DCPT-01-KIT). Ideal for industrial applications requiring stringent safety compliance, this module integrates seamlessly with external safety systems or safety PLCs, providing reliable protection and operational efficiency.
Key features include:
- **Safe Torque Off (STO)**: Immediately switches off drive output to the motor, disabling torque-generating energy. Used for emergency stops or preventing unexpected starts, fulfilling stop category 0 (IEC 60204-1).
- **Safe Stop 1 (SS1)**: Enables controlled motor deceleration followed by STO activation, fulfilling stop category 1 (IEC 60204-1). Reduces risk of danger, eliminates external safety timers, and increases machine productivity.
- **Safe Brake Control (SBC)**: Monitors and controls brake activation for safe stopping.
- **Safely-Limited Speed (SLS)**: Ensures motor speed remains within configured limits.
- **Advanced Safety Functions**: Includes Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and Prevention of Unexpected Start-up (POUS) for enhanced safety.
- Supports EN/IEC 61800-5-2:2007 safety functions: STO, SBC, SS1, SLS
- Additional safety functions: SSE, SMS, POUS
- Monitors drive operations and activates STO if limits exceeded
- Requires Drive Composer Pro (DCPT-01-KIT) for commissioning
- SIL 3/PL e safety performance level, no external safety relays needed

DLC400BP
The TORK DLC400BP SunSet 365-Day Astronomic Digital Timer is designed for providing total control over 4 different output channels in indoor or outdoor applications. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to activate lights or signage when the ambient light level drops below a customizable threshold. Features four output channel, different settings for holidays and seasons and a 6-month battery backup. Designed for commercial applications including lighting, HVAC equipment, signage, store windows and security or parking lot lights.
2TLA020070R4700
Safety PLC. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus). NOTE: Version 2 hardware/processor.
C6200.0060
FlexGen Generator Controller - Basic. Integrated generator controller. The C6200 provides load depending start and stop, automatic synchronization and active / reactive load sharing for one diesel generator (3 phase). The C6200 will also ensure that the generator is always operating at the nominal speed / frequency no matter the load. Advanced grid paralling and Power Factor function are provided as standard. Programmable inputs and outputs allows for easy integration with PLC control. The C6200 can be operated in either fully automatic mode, semi-automatic mode or in manual mode.
RCNT-01-RJ45
The data cable splitter with terminal block is a 3-way 'Y' cable splitter with one terminal block suitable for an RS-485 network of drives. Two of the three connections are compatible with standard CAT 5 or CAT 6 type cable and the third is a terminal block that can be used to connect a PLC or network terminating resistor.
PAC79