Kessler Ellis iR-DQ16-N - iR SERIES DIG OUT 16 SINK
Kessler Ellis

iR-DQ16-N

Contact for Pricing

Overview

The Kessler Ellis iR SERIES DIG OUT 16 SINK (SKU: iR-DQ16-N) is a 16-inch industrial sink engineered for efficient drainage in demanding environments. Constructed from durable stainless steel, this sink is built to withstand the rigors of manufacturing, food processing, and laboratory settings. Its deep basin design facilitates effective removal of water and waste, ensuring operational cleanliness and safety. As part of the Kessler Ellis iR Series, it is designed to integrate seamlessly with their comprehensive industrial drainage systems, providing a reliable and cohesive solution for facilities requiring robust waste management. The stainless steel material offers excellent corrosion resistance and is easy to clean, making it ideal for high-traffic areas where hygiene and low maintenance are paramount. This 16-inch sink is a practical choice for any industrial application needing dependable drainage.
  • 16-inch stainless steel industrial sink
  • Designed for heavy-duty drainage
  • Durable stainless steel construction
  • Deep basin for efficient waste removal
  • Part of the Kessler Ellis iR Series

Specifications

Material
Stainless Steel
Series
iR Series
Size
16-inch
The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.

FSO-12-KIT

The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.
The data cable splitter with terminal block is a 3-way 'Y' cable splitter with one terminal block suitable for an RS-485 network of drives. Two of the three connections are compatible with standard CAT 5 or CAT 6 type cable and the third is a terminal block that can be used to connect a PLC or network terminating resistor.

RCNT-01-RJ45

The data cable splitter with terminal block is a 3-way 'Y' cable splitter with one terminal block suitable for an RS-485 network of drives. Two of the three connections are compatible with standard CAT 5 or CAT 6 type cable and the third is a terminal block that can be used to connect a PLC or network terminating resistor.
5" to 7" HMI Screen Cover (HMI-0700-003)

100-1071

5" to 7" HMI Screen Cover (HMI-0700-003)
M12 network/LAN cable/3m

100-1024

M12 network/LAN cable/3m
M12 cable connector for network/LAN cable

100-1149

M12 cable connector for network/LAN cable
M12 network/LAN cable/10m

100-1152

M12 network/LAN cable/10m
INTERFACE MODULE KIT HMI-01

HMI-01

INTERFACE MODULE KIT HMI-01
INTERFACE MODULE F/ HMI MIS-CFW08-RS

MIS-CFW08-RS

INTERFACE MODULE F/ HMI MIS-CFW08-RS