Authorized ABB - Low Voltage Drives Distributor
ABB - Low Voltage Drives RCNT-01-RJ45 - The data cable splitter with terminal block is a 3-way 'Y' cable splitter with one terminal block suitable for an RS-485 network of drives. Two of the three connections are compatible with standard CAT 5 or CAT 6 type cable and the third is a terminal block that can be used to connect a PLC or network terminating resistor.
ABB - Low Voltage Drives

RCNT-01-RJ45

Alternate Item Number: 3AUA0000149996

UPC: 662348077047

Contact for Pricing

Overview

The ABB RCNT-01-RJ45 data cable splitter, SKU RCNT-01-RJ45, is a vital component for establishing robust RS-485 communication networks within industrial drive systems. Manufactured by ABB Low Voltage Drives, this 3-way 'Y' splitter is engineered for efficient data distribution. It features two RJ45 connections compatible with standard CAT 5 or CAT 6 Ethernet cables, facilitating easy integration with existing drive infrastructure. The third connection is a terminal block, offering versatile connectivity options. This terminal block can be directly wired to a Programmable Logic Controller (PLC) for centralized control or used to connect a network terminating resistor, ensuring signal integrity on longer RS-485 runs. Designed for low-voltage drive applications, the RCNT-01-RJ45 simplifies network setup and maintenance. Its construction prioritizes reliable data transmission, crucial for the stable operation of automated industrial processes. This splitter is an essential tool for system integrators and maintenance engineers looking to expand or optimize their drive network configurations. The product originates from Denmark (DK) and adheres to UNSPSC code 39122004. Ensure stable and efficient data flow in your industrial automation setup with this dependable ABB networking solution.
  • 3-way 'Y' cable splitter for RS-485 networks
  • Two RJ45 connections compatible with CAT 5/6 cables
  • One terminal block for PLC or network terminating resistor connection
  • Designed for ABB Low Voltage Drives applications
  • Ensures stable and efficient data transmission
GT-2744

100-8010

GT-2744
AI830A Analog input RTD 8 ch

3BSE040662R1

AI830A Analog input RTD 8 ch
The TORK DLC400BP SunSet 365-Day Astronomic Digital Timer is designed for providing total control over 4 different output channels in indoor or outdoor applications. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to activate lights or signage when the ambient light level drops below a customizable threshold. Features four output channel, different settings for holidays and seasons and a 6-month battery backup. Designed for commercial applications including lighting, HVAC equipment, signage, store windows and security or parking lot lights.

DLC400BP

The TORK DLC400BP SunSet 365-Day Astronomic Digital Timer is designed for providing total control over 4 different output channels in indoor or outdoor applications. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to activate lights or signage when the ambient light level drops below a customizable threshold. Features four output channel, different settings for holidays and seasons and a 6-month battery backup. Designed for commercial applications including lighting, HVAC equipment, signage, store windows and security or parking lot lights.
INTERFACE MODULE KIT HMI-01

HMI-01

INTERFACE MODULE KIT HMI-01
The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.

FSO-12-KIT

The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.
RG_N CONTROLLER MODBUS RTU 2 WIRE + TERM RES

NRGC

RG_N CONTROLLER MODBUS RTU 2 WIRE + TERM RES
COIL AF190 PLC 24-60 V 50/60HZ,20-60VDC

ZAF190-31

COIL AF190 PLC 24-60 V 50/60HZ,20-60VDC
Aluminum Type PAC - Aluminum Parallel Groove Clamp with Cast Copper Liner for Wire Range Main: 336.4-1/0, 1/0-6 AR ASCR 400-2/0 Str., 1/0-6 AR AL/CU, Tap: ASCR 1/0 Str.-8 Sol. ALCU, Prefilled with Oxide Inhibitor.

PAC79

Aluminum Type PAC - Aluminum Parallel Groove Clamp with Cast Copper Liner for Wire Range Main: 336.4-1/0, 1/0-6 AR ASCR 400-2/0 Str., 1/0-6 AR AL/CU, Tap: ASCR 1/0 Str.-8 Sol. ALCU, Prefilled with Oxide Inhibitor.
E208i p SR G10 Controller

836266-001

E208i p SR G10 Controller
iR SERIES DIG OUT 16 SINK

iR-DQ16-N