ABB Low Voltage Drives P14494-30 Braking Resistor, 45 OHMS, 4400 WATTS, GCE12 Enclosure, 26.5W x 13D x 5H in, 32 lbs
Alternate Item Number: 3AUA0000015111
UPC: 662348076231
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 45 OHM resistance for effective energy dissipation
- 4400 WATTS power rating for demanding applications
- GCE12 enclosure for protection and easy mounting
- Compact dimensions: 26.5" W x 13" D x 5" H
- 32 lbs weight for manageable installation

FMK-A-R3
R3 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00. R1 through R4 flange kits can be used with 3rd party UL Type 1 & 12 (NEMA 1 & 12) enclosures.Frequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors dissipate regenerated power to prevent bus voltage from exceeding the drive's rated limit, increasing braking torque for faster, controlled braking.
What is the purpose of braking modules with variable frequency drives?
Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and improve system performance.
How are Powerohm Type CR resistors constructed?
They feature a nickel-chromium wire helically wound inside a ceramic fixture, housed in a corrosion-resistant aluminum case with high-temperature wire leads.
What is the voltage range for ACS150 and ACS355 single-phase applications?
These drives are for single-phase 200-240V applications and are for stopping duty only.
What is the voltage range for ACS150 and ACS355 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are for stopping duty only.
What is the voltage range for ACS250 single-phase applications?
These drives are for single-phase 100-120V and 200-240V applications and are for stopping duty only.
What is the voltage range for ACS250 three-phase UL Type 4X drives?
These drives are for three-phase 200-240V and 380-480V applications and are for stopping duty only.
What is the voltage range for ACS250 three-phase drives (non-UL Type 4X)?
These drives are for three-phase 575-690V applications and are for stopping duty only.
What is the voltage range for ACS550 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are for stopping duty only.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads, providing a safety mechanism.