ABB Low Voltage Drives P14494-28 Braking Resistor, 45 OHMS, 2450 WATTS, GCE8 Enclosure, 19W x 13D x 5H in, 24 lbs
Alternate Item Number: 3AUA0000015109
UPC: 662348076217
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Resistance: 45 ohms for precise energy dissipation
- Power rating: 2450 watts continuous operation
- Enclosure: GCE8-rated for environmental protection
- Dimensions: 19" W x 13" D x 5" H, 24 lbs weight
- Designed for ABB low-voltage drive applications
Specifications
Size | 19W x 13D x 5H in |

FMK-A-R2
R2 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00. R1 through R4 flange kits can be used with 3rd party UL Type 1 & 12 (NEMA 1 & 12) enclosures.
ABB-48431-519
Braking Resistor, 1 OHMS, 122500 WATTS, (2) ED5 Enclosure, (2) 30W x 18D x 40H in, 605 lbsFrequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors are used to dissipate regenerated power, preventing the bus voltage from exceeding the drive's rated limit, and increasing braking torque for faster, more controlled deceleration.
When are braking modules used with variable frequency drives?
Braking modules are used to monitor the drive's DC bus and activate external braking resistors to manage regenerated power and avoid over-voltage trips.
What is the purpose of a braking resistor in overhauling load conditions?
In overhauling load conditions, braking resistors dissipate regenerated power flowing from the motor back into the drive, preventing DC bus over-voltage.
How are Powerohm Type CR resistors constructed?
They feature a nickel-chromium wire helically wound inside a ceramic fixture, housed in a corrosion-resistant aluminum case with high-temperature wire leads encapsulated in ceramic potting material.
What is the function of the thermal switch in GCE and ED enclosures?
A normally closed thermal switch is provided to detect resistor temperature overloads and alert the user.
What is the voltage range for ACS150 and ACS355 single-phase applications?
These drives are for single-phase 200-240V applications.
What is the voltage range for ACS150 and ACS355 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications.
What is the voltage range for ACS250 single-phase applications?
These drives are for single-phase 100-120V and 200-240V applications.
What is the voltage range for ACS250 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications.
What is the voltage range for ACS550 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications.