ABB Installation Products ULCK 2 HS Copper Heat-Shrink In-Line Compression Splice Kits, conductor size 2 Copper, includes…
UPC: 783786780181
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for 2 AWG copper conductors
- Includes compression splice and heat-shrink tubing
- Exceeds ANSI C119.1 requirements
- Pre-lubricated heat-shrink tubing for easy installation
- Provides environmental protection against moisture and corrosion
Specifications
Conductor Range | #2 AWG |
Connection | Compression |
Material | Copper |
Number Of Conductors | 2 |
Size | 2 |
Special Features | Heat-Shrink Kits include Pre-Sized Heat-Shrink Tubing. Crimp the two pieces of wire together, then heat the splice with a hot-air gun to get a fully sealed watertight repair splice. Includes one submersible Splice Cover to ensure a fully insulated, watertight repair splice. Connectors have a Center Cable Stop to Ensure Equal Cable Insertion |
Standard | UL E100543 |
Type | Compression Splice Service Entrance Insulated |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

271-30630-4
Long Barrel Two-Way Copper Connector, Cable Size 2 STR, Navy 60 (37), Length 2-5/8 Inches, Diameter 13/32 Inch, Die Color Brown, Die Code 33, Silver Plated
AAC 350 FT
Aluminum Multi-Range Dieless Compression Splices AAC Series - Full Tension, conductor size 4 str - 350 aluminum - 336.4 (18/1) 9-1/2 inch long
SAC 350 R 1/0 TN
Tin Plated Aluminum Reducing Splice. Wire Range 350 kcmil AL-CU to 1/0 Stranded - Compressed, 2/0 Compact - Solid. Installing Dies 96, 299, 655, 321, 1 1/8-1, 13A. Length 5 Inches. Oil Stop. Oxide Inhibitor. Clear Cap. Yellow Cap.
FSK 1/0 R 2
Aluminum Flood-Seal Compression Splice Kits, wire range 1/0 STR CPT COMP AL-CU to #2 STR CPT COMP AL-CU, Kit contains Splice, FSS 20 Cover and Cap, Silicone Grease and Instruction Sheet.
AC 800 R 600
Aluminum Straight Reducing Splice, Wire size 800-600 KCMIL. Length 8-1/4 inch, Diameter 1-5/8 inch. Bore Depth 4-1/16 inch on 1-5/8 inch Diameter end and 3-47/64 inch on the 1 inch Diameter end. Dies 140H, 474, 342, 724m 1 1/2H, 1 5/8. 900 Compact, 750-900 kcmil AL-CU, 636 (30/19), 715.5 (54/7) ACSR. 600 kcmil AL-CU, 477 (26.7), 556.5 (18/1) ACSR. Oil Stop. Oxide Inhibitor, (1) 800 Blue Cap, (1) 600 Black Cap.
ULCK 1
Copper Flood-Seal In-Line Compression Splice Kits, includes Insulating Cover Cap and Rocket, (1) Tin Plated Copper Straight Splice - Standard barrel, wire size #1 Stranded CU, Length 1-7/8 inch, Installing Dies TB, 37. Dimple. No Center Stop. CSA. UL listed. Silicone Grease and Instruction Sheet.How to Install a Heat-Shrink Compression Splice Kit
This guide provides step-by-step instructions for installing a heat-shrink compression splice kit, covering cable preparation, connector crimping, and proper heat-shrink application for a secure splice.
Estimated time: 30m
Tools needed:
Torches, Wire brush, Crimping tool
Supplies needed:
Heat-shrink tubing, Compression connector, Oxide inhibitor
- Prepare Cable Insulation
WARNING: Risk of shock, disconnect power before installation. Strip both ends of the cable insulation to a length equal to half the connector's length plus an additional 1/4 inch. CAUTION: Wear safety glasses and protective gloves.
- Clean Cable Insulation
Thoroughly clean the prepared cable insulation on both ends to ensure proper adhesion and splice integrity.
- Position Heat-Shrink Tubing
Carefully place the heat-shrink tubing over one of the clean cable ends. Ensure the tubing is protected from potential damage by the conductor strands as it slides over the cable end.
- Prepare Conductor Strands
Wire brush the conductor strands to remove any oxidation. If working with aluminum conductors, coat the conductor with an oxide inhibitor and wire brush it thoroughly into the strands.
- Install and Crimp Connector
Install the compression connector onto the prepared cable ends, ensuring proper seating. Crimp the connector using the recommended die size marked on the connector itself. After crimping, clean and deburr the connector if necessary.
- Shrink Heat-Shrink Tubing
Center the heat-shrink tubing over the splice and hold it firmly in position. Using a torch, apply the outer 3-4 inch tip of the flame to the heat-shrinkable material with a rapid, brushing motion. Continuously move the flame to prevent scorching. Begin shrinking at the center of the tube, applying uniform heat around all sides. Once the center is shrunk, work the torch towards one end, then to the opposite end, until the entire tube is completely shrunk.
- Inspect and Cool Splice
Inspect the completed splice. A properly installed tube will be smooth, conform tightly to the connection, and adhesive will be visible at both ends. Reheat any flat spots or wrinkles as needed. Allow the installation to cool completely before touching, moving, or placing it into service.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.