Overview

The ABB STX200-472PVC Star Teck XP hazardous location cable fitting hub is a critical component for safe, reliable cable entry in explosive and dust-prone environments. Designed for Class I Div. 2, Class II Div. The 2-inch hub size accommodates cables with outer jacket diameters from 1.700 to 1.965 inches, providing a secure, leak-tight seal that resists corrosion and environmental damage. Engineered for rapid installation, the STX200-472PVC features a disconnectable construction that minimizes cable preparation time. The integral sealing chamber simplifies filling with liquid or putty sealants, reducing labor and material waste. The hexagonal gland nut offers dependable tool grip, while internal splines allow tightening either on or off the enclosure. The twist-on union provides easy connection and disconnection, with a high-visibility red color for quick identification. A stainless steel retaining ring ensures durability in corrosive environments, and the low-profile design fits tight spaces. The Power Grip design secures the cable armor high up on the jacket, eliminating the need for precise cable preparation. The non-magnetic stainless steel construction resists corrosion and magnetic interference. With overlapping sizes to prevent mismatched cables and fittings, the STX200-472PVC is part of the Star Teck XP series, which spans hub sizes from ½" to 4" and handles jacket diameters from 0.525" to 4.34". This fitting is ideal for petrochemical, oil and gas, and other industrial applications where safety and reliability are non-negotiable.
  • Working with engineers from the petrochemical, oil and gas industries, Thomas & Betts then introduced the STAR TECK XP fitting.
  • With an easy-to-fill, integral sealing chamber and a disconnectable design requiring minimal cable preparation, this fitting became the benchmark for ease of installation in hazardous environments.
  • A line of liquid and putty sealants was also developed at the same time, eliminating the need for the cement sealants used up to this point.
  • Stainless steel retaining ring and non-magnetic construction for durability
  • Disconnectable design requires minimal cable preparation.

Specifications

Application
For Hazardous Locations
Color
Black
Finish
PVC
Material
Aluminum
Material
PVC Coated
Series
STAR TECK XP
Size
2 Inches
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.1000 L
Package Weight (Metric)
0.9530 kg
Star Teck jacketed cable fitting PVC coated. Hub size of 2-1/2 inches. Range over jacket from 2.380 - 2.640 inches.

ST250-477PVC

Star Teck jacketed cable fitting PVC coated. Hub size of 2-1/2 inches. Range over jacket from 2.380 - 2.640 inches.
Entrance Cap, Threaded, Aluminum, Size 2-1/2 Inch

1207

Entrance Cap, Threaded, Aluminum, Size 2-1/2 Inch
Watertight fitting body made of aluminum with a hub thread size of 3/4 inch.

10467AL-BODY

Watertight fitting body made of aluminum with a hub thread size of 3/4 inch.
90 Degree EMT elbow. Size 2 Inch. Steel.

EMT90-200

90 Degree EMT elbow. Size 2 Inch. Steel.
Connector, Non-Metallic Sheathed Cable, Size 1/2 Inch, Total Length 15/16 Inch, Width 7/8 Inch, Clamping Range Minimum 0.21 Inch to Maximum 0.42 Inch, Non-Metallic, Suggested Application 14/2-10/2, 14/3-10/3 2 Cables: 14/2-12/2, Pack of 175

CI4004-FP3

Connector, Non-Metallic Sheathed Cable, Size 1/2 Inch, Total Length 15/16 Inch, Width 7/8 Inch, Clamping Range Minimum 0.21 Inch to Maximum 0.42 Inch, Non-Metallic, Suggested Application 14/2-10/2, 14/3-10/3 2 Cables: 14/2-12/2, Pack of 175
Connector, Non-Metallic Sheathed Cable, Size 1/2 Inch, Total Length 15/16 Inch, Width 7/8 Inch, Clamping Range Minimum 0.21 Inch to Maximum 0.42 Inch, Non-Metallic, Suggested Application 14/2-10/2, 14/3-10/3 2 Cables: 14/2-12/2

CI4004-FP5

Connector, Non-Metallic Sheathed Cable, Size 1/2 Inch, Total Length 15/16 Inch, Width 7/8 Inch, Clamping Range Minimum 0.21 Inch to Maximum 0.42 Inch, Non-Metallic, Suggested Application 14/2-10/2, 14/3-10/3 2 Cables: 14/2-12/2
Steel Snap-In Fittings for MC cable, Size 1/2 Inch, Diameter 0.840 Inches, Length 1 Inch, Material Electro-Zinc Plated Steel, Accommodates the widest range of MC cable size in the industry - 14-2 to 10-3, Package 5

XC-130-5R

Steel Snap-In Fittings for MC cable, Size 1/2 Inch, Diameter 0.840 Inches, Length 1 Inch, Material Electro-Zinc Plated Steel, Accommodates the widest range of MC cable size in the industry - 14-2 to 10-3, Package 5
Steel Snap-In Fittings for MC cable, Size 1/2 Inch, Diameter 0.840 Inches, Length 1 Inch, Material Electro-Zinc Plated Steel, Accommodates the widest range of MC cable size in the industry - 14-2 to 10-3, Package 50

XC-130-50R

Steel Snap-In Fittings for MC cable, Size 1/2 Inch, Diameter 0.840 Inches, Length 1 Inch, Material Electro-Zinc Plated Steel, Accommodates the widest range of MC cable size in the industry - 14-2 to 10-3, Package 50

How to Install the STX200-472PVC Cable Fitting

Instructions for preparing and installing the STX200-472PVC Star Teck™ PVC cable fitting, including sealing procedures.

Estimated time: 1h

Tools needed:

Hacksaw, Strap wrenches (for PVC coated fittings), Wooden dowel (for putty sealant)

Supplies needed:

SC4-KIT-1 Liquid Sealant or SC65 Putty Sealant (purchased separately), Lubricant

  1. Prepare the cable jacket and armor

    Determine the working length. Remove a portion of the outer jacket to expose the armor, then cut the armor using a hacksaw. Be careful not to nick the conductor insulation. Trim the outer jacket to expose the armor strip length as indicated in the table.

  2. Cut the cable boot

    To determine where to cut the cable boot, either unscrew the gland nut and force the cable into the boot, cutting the boot in front of the cable, or progressively cut slices off the boot until it can snugly slide on the armor.

  3. Feed cable through gland nut

    Feed the cable through the gland nut opening and push until the cable armor hits the end stop. Apply lubricant where indicated prior to screwing the gland nut.

  4. Tighten the gland nut

    Tighten the gland nut until an appropriate seal is obtained or to the maximum torque specified in the table. Ensure the cable remains centered for an optimal seal. For PVC coated fittings, use strap wrenches only.

  5. Prepare for sealing

    Disassemble the hub from the body sub-assembly. Unscrew the sealing chamber from the body sub-assembly. For shielded data cables, trim the inner jacket to 1/8"-3/8" to expose the conductor bundle, remove the outer shield, and remove filler materials without disturbing inner shields.

  6. Apply sealing compound

    If using SC4-KIT-1 liquid sealant, pack fiber damming material into voids and spread grounding conductor strands. Mix the compound, dispense into the sealing chamber until the level stabilizes (fill to the top for fittings up to STX250-476, or half for larger fittings, wait 2 hours, then fill to the top). If using SC65 putty sealant (not for shielded cables or cables with 5+ conductors), mix the two parts until uniform, apply to conductors and fill voids, then slide the sealing chamber onto the cable and compound, screwing it to the body sub-assembly. Pack compound tightly around conductors in the throat area using a wooden dowel.

  7. Assemble and secure the fitting

    Screw the sealing chamber back onto the body sub-assembly. Mount the hub in the desired location. Once the sealing compound is solidified (approximately 1 hour for liquid, or set for approximately one hour after packing for putty), place the encapsulated assembly into the hub and secure by tightening the union until it bottoms (metal to metal contact). Clean any excess compound from the outside of the sealing chamber with a damp cloth.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.