Authorized ABB Distributor (Installation Products)
ABB - Installation Products STX050-464SPVC - Steel PVC fitting with a hub size of 1/2 inch and the outer jacket diameters from 0.6 to 0.76 inch.

ABB Installation Products STX050-464SPVC Steel PVC fitting with a hub size of 1/2 inch and the outer jacket diameters from 0.6 to…

UPC: 786209983145


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB STX050-464SPVC is a steel conduit fitting with a PVC outer jacket, part of the STAR TECK XP line. This fitting features a 1/2" NPT hub and accommodates outer jacket diameters from 0.6 to 0.76 inches, making it compatible with armored and non-armored cables. The integral sealing chamber allows for easy filling with liquid or putty sealants, eliminating the need for traditional cement sealants. The disconnectable design reduces cable preparation time, improving field installation efficiency. With a gland torque rating of 300 lb-in, it provides a reliable mechanical and environmental seal. Dimensions are A: 0.485 in, B: 2.020 in, C: 1.363 in. Engineered for use in petrochemical, oil, and gas sectors, this fitting ensures durable, corrosion-resistant conduit connections where moisture and chemical resistance are critical. The steel construction provides structural integrity, while the PVC jacket offers additional protection against environmental hazards.
  • Working with engineers from the petrochemical, oil and gas industries, Thomas & Betts then introduced the STAR TECK XP fitting.
  • With an easy-to-fill, integral sealing chamber and a disconnectable design requiring minimal cable preparation, this fitting became the benchmark for ease of installation in hazardous environments.
  • A line of liquid and putty sealants was also developed at the same time, eliminating the need for the cement sealants used up to this point.
  • Disconnectable design reduces cable preparation time
  • Gland torque rating of 300 lb-in for reliable sealing

Specifications

Application
For Hazardous Locations
Color
Black
Finish
PVC
Material
Steel
Size
1/2 Inch
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.7200 L
Package Weight (Metric)
0.3270 kg
Steel Star Teck XP hazardous location jacketed cable fitting, hub size 1-1/2 inches PVC coated.

STX150-550SPVC

Steel Star Teck XP hazardous location jacketed cable fitting, hub size 1-1/2 inches PVC coated.
Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch

685-UI

Connector, Adjustable Endstop, MC Feeder Cable, Two Screw, Steel, 1-1/2 Inch
KIT GREASE FITTING WITH EXTENSION

GF 250 ODE-W22

KIT GREASE FITTING WITH EXTENSION
Steel fitting with a hub size of 3/4 inch and the outer jacket diameters from 0.725 to 0.885 inch. PVC coated.

STX075-465SPVC

Steel fitting with a hub size of 3/4 inch and the outer jacket diameters from 0.725 to 0.885 inch. PVC coated.
Steel fitting with a hub size of 3/4 inch and the outer jacket diameters from 0.825 to 0.985 inch. PVC coated.

STX075-466SPVC

Steel fitting with a hub size of 3/4 inch and the outer jacket diameters from 0.825 to 0.985 inch. PVC coated.
Steel fitting with a hub size of 1 inch and the outer jacket diameters from 0.88 to 1.065 inch. PVC coated.

STX100-467SPVC

Steel fitting with a hub size of 1 inch and the outer jacket diameters from 0.88 to 1.065 inch. PVC coated.
Steel Star Teck XP hazardous location jacketed cable fitting hub size 2 inches PVC coated.

STX200-472SPVC

Steel Star Teck XP hazardous location jacketed cable fitting hub size 2 inches PVC coated.
Steel fitting with a hub size of 1-1/4 inches and the outer jacket diameters from 1.187 to 1.375 inches. PVC coated.

STX125-469SPVC

Steel fitting with a hub size of 1-1/4 inches and the outer jacket diameters from 1.187 to 1.375 inches. PVC coated.

Frequently Asked Questions

What is the cable armor diameter range for STX050-464SPVC?

The range over the cable armor for STX050-464SPVC is from 12.45 mm (0.490 in) minimum to 17.27 mm (0.680 in) maximum.

What is the cable jacket diameter range for STX050-464SPVC?

The range over the cable jacket for STX050-464SPVC is from 15.24 mm (0.600 in) minimum to 19.30 mm (0.760 in) maximum.

What is the maximum sealing compound volume for STX050-464SPVC?

The maximum volume of sealing compound required for the STX050-464SPVC is 5cc.

What is the NPT thread size for STX050-464SPVC?

The STX050-464SPVC has a 1/2 NPT thread size.

Is the product RoHS compliant?

Yes, the product conforms to the RoHS (Restriction of Hazardous Substances Directive) 2011/65/EU, including the 2015/863 amendment.

Is the product suitable for wet and dry locations?

Yes, the product conforms to UL514B and CSA C22.2-18.3 for use in both wet and dry locations.

What hazardous location classifications does it meet?

The product conforms to Class I Div1 ABCD, Class II Div1 EFG, and Class III Div1 under CSA 22.2 and UL2225 standards.

What is the ingress protection rating?

The product has an ingress protection rating of Type 4 / 4X.

What cable types are compatible with this fitting?

This fitting is suitable for jacketed Teck and ACWU, armored control and instrument (ACIC Div2 locations), and Type MC jacketed corrugated metal clad cables (aluminum and steel).

When should SC4-KIT-1 sealing compound be used?

SC4-KIT-1 liquid compound should be used for shielded cables and cables with 5 conductors or more, including ground.

How to Install the STX050-464SPVC Cable Fitting

This guide provides step-by-step instructions for preparing, assembling, and sealing the STX050-464SPVC Star Teck PVC cable fitting for power cables or shielded data cables. Ensure all circuits are de-energized before beginning installation.

Estimated time: 2h

Tools needed:

Hacksaw, Wire strippers, Strap wrenches, Wooden dowel

Supplies needed:

STX050-464SPVC cable fitting, SC4-KIT-1 LIQUID SEALANT (purchased separately), SC65 PUTTY SEALANT (purchased separately), Lubricant, Fiber damming material (for liquid sealant), Gloves, Damp cloth

  1. Prepare the Cable Armor and Jacket

    Determine the required working length of conductors inside the enclosure. Carefully remove a portion of the cable's outer jacket to expose the armor, then cut the armor using a hacksaw. CAUTION: Exercise caution to avoid nicking or cutting the conductor insulation. Trim the outer jacket to the specified strip length of 0.485 inches for the STX050-464PVC fitting.

  2. Prepare and Fit the Cable Boot

    Unscrew the gland nut from the fitting body. Determine the correct cutting point for the cable boot by either forcing the square-cut cable into the boot and cutting the boot in front of the cable, or by progressively cutting slices off the boot until the opening snugly slides onto the cable armor. Apply lubricant where indicated prior to screwing the gland nut.

  3. Secure the Cable and Tighten Gland Nut

    Feed the prepared cable through the gland nut opening and push it until the cable armor firmly hits the end stop. Tighten the gland nut to achieve an appropriate seal, or to the maximum torque of 300 IN-LBS for the STX050-464PVC fitting. Ensure the bushing seals evenly around the cable's outer jacket and the cable remains centered for an optimal seal. Use strap wrenches for PVC coated fittings.

  4. Disassemble for Sealing Compound Application

    Disassemble the hub from the body sub-assembly by loosening the union. Then, unscrew the sealing chamber from the body sub-assembly. If installing shielded data cables, trim the inner jacket to 1/8”-3/8” to expose the shielded conductor bundle, remove the outer shield, and remove filler materials, taking care not to damage inner shields or conductors.

  5. Apply Sealing Compound

    Choose between SC4-KIT-1 LIQUID SEALANT or SC65 PUTTY SEALANT based on your cable type (SC65 is not for shielded cables or those with 5 or more conductors including ground). Prepare the compound according to its specific instructions. For liquid, pack fiber damming material, position the fitting vertically, and fill the sealing chamber. For putty, mix thoroughly, apply around conductors to form a plug, and pack it into the chamber. CAUTION: Remove all excess compound from outside the sealing chamber with a damp cloth. Do not use abrasive cleaners. WARNING: Wear appropriate PPE, including gloves, when handling putty sealant.

  6. Final Assembly and Curing

    Mount the hub in the desired location. Once the sealing compound has solidified (approximately 1 hour), place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms (metal to metal contact). If using putty, repack compound tightly around conductors if required. Allow the compound to set for approximately one hour before disturbing conductors.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.