Authorized ABB Distributor (Installation Products)
ABB - Installation Products SS1 2 FN 500K - Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

ABB Installation Products SS1 2 FN 500K Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly…

UPC: 783786753475


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 12

Multiplier: 12

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Storm-Safe Breakaway Service Entrance Kit, SKU SS1 2 FN 500K, is engineered for reliable and safe electrical service entrance connections. This kit features a triplex block with a 2,2,2 size configuration, designed to accommodate standard service entrance cable sizes. It incorporates a full neutral assembly, ensuring complete and robust neutral connectivity for the electrical system. A critical safety feature of this kit is its breakaway functionality, rated at a 500 Pound Break Force. This specification is crucial for installations in areas prone to high winds or potential physical impact, as it allows the service entrance cable to detach safely under excessive stress, preventing damage to the meter base, the structure, and minimizing the risk of electrical hazards. The 3-pole configuration provides the necessary connections for a standard residential or commercial service entrance. Manufactured by ABB - Installation Products, this kit offers a direct and spec-driven solution for service entrance applications where safety and reliable performance are paramount. The Storm-Safe series is designed with specific breakaway force ratings to meet safety codes and provide a defined failure point under extreme conditions, protecting valuable electrical infrastructure. This unit is ideal for new installations or upgrades requiring a dependable service entrance connection with enhanced safety features.
  • ABB Storm-Safe Breakaway Service Entrance Kit
  • 500 Pound Breakaway Force for enhanced safety
  • Triplex block with 2,2,2 size configuration
  • Full neutral assembly for complete connectivity
  • 3-pole configuration for standard service entrance

Specifications

Application
Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises
Insulation
Yes
Special Features
Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts
Type
Storm-Safe Service Entrance Disconnect Pin Kits
Wire Size
#2 AWG
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.5200 L
Package Weight (Metric)
0.6900 kg
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

SS1 2 FN 750K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,2, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SS1 1/0 RN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,2, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SS1 2 RN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SS1 4 FN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

SS1 4 FN 750K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,6, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SS1 4 RN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,6, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits- two service base kit, contact block - 1, assembly - 1 U-bolt, insulating rockets - 2 Flood-Seal , bolts - 3, bolt size - 1/2-13

SS2 K

Storm-Safe Breakaway Service Entrance Kits- two service base kit, contact block - 1, assembly - 1 U-bolt, insulating rockets - 2 Flood-Seal , bolts - 3, bolt size - 1/2-13
Storm-Safe Pin Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SSP 2 RN 500K

Storm-Safe Pin Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

Frequently Asked Questions

What components are included in an SSP pin kit?

An SSP pin kit consists of two pin terminals, one neutral pin terminal, one SSL link kit (breakaway link and bail), and two Flood-Seal insulating rockets.

How many pin kits are needed for multi-service base kits?

The SS 2 K two-service base kit requires two SSP pin kits, and the SS 3 K three-service base kit requires three SSP pin kits.

What is included in a multi-service base kit like SS 2 K?

A multi-service base kit includes one contact block, one U-bolt, two Flood-Seal insulating rockets, and three 1 1/2"–13 bolts.

What components are included in a single-service breakaway kit?

A single-service kit includes two sockets, one neutral socket, two pin terminals, one neutral pin terminal, one SSL link kit, two Flood-Seal insulating splice covers, and one Flood-Seal insulating rocket.

What are the conductor specifications for SS1 2 FN 500 K?

The SS1 2 FN 500 K kit is designed for #2, #2, #2 conductors with a full neutral assembly and a 500 lbs breakaway force.

What are the available breakaway force options for SSL Link Kits?

SSL Link Kits are available with breakaway forces of 500 lbs and 750 lbs.

What industry standards does the Storm-Safe system meet?

The Storm-Safe service entrance breakaway disconnect system meets ANSI C119.4-2004 specifications.

What conductor types are compatible with Storm-Safe disconnects?

The Blackburn Storm-Safe system is dual rated for use with both aluminum and copper conductors.

What are the conductor specifications for SS1 2 FN 500 K?

The SS1 2 FN 500 K kit is designed for #2, #2, #2 conductors with a full neutral assembly and a 500 lbs breakaway force.

What are the available breakaway force options for SSL Link Kits?

SSL Link Kits are available with breakaway forces of 500 lbs and 750 lbs.

How to Install the SS1 Series Service Entrance Disconnect System

This guide details the installation and wiring of the SS1 Series Service Entrance Disconnect System, covering cable preparation, component connection, and power reconnection. WARNING: Installation must be performed by trained installers in accordance with all applicable local, state and national electrical codes, installation standards and safety rules. Always follow standard safety practices when working on energized circuits and wear insulated gloves rated to the appropriate voltage when installing on live conductors.

Estimated time: 1h 30m

Tools needed:

Approved safety cutting device, Crimp die (5/8 or equivalent)

Supplies needed:

Neutral wedge clamp, Breakaway link, CSN 2277 Flood-Seal® Insulating rockets (long covers), Flood-Seal® caps, CS 2277 Flood-Seal® insulating rocket (short cover), Silicone grease, Socket connectors, Pin connectors, Hot Load-Side Pin, Hot Feed-Side Socket, Neutral Pin, Neutral Socket, Flood Seal® Insulating Rocket

  1. Disconnect Power and Secure Service Drop

    Disconnect the power cables from the transformer or feed and secure the service drop. Ensure power is fully disconnected and secured before proceeding.

  2. Install Breakaway Link

    Open the neutral wedge clamp and install the breakaway link between the wedge clamp and pole hardware. Tighten the service drop as required.

  3. Cut and Trim Service Cables

    Cut the service cables from the transformer or feed. Trim the load-side cables so that the neutral is 6” to 12” longer than the hot (energized) cables. This ensures that the neutral disconnects last in a storm event.

  4. Install Hot Feed-Side Insulating Rockets

    Cut two CSN 2277 Flood-Seal® Insulating rockets (long covers) at the appropriate ring using an approved safety cutting device. Install them on the feed side of the hot cables. Apply silicone grease to the cables to ease installation.

  5. Install Load-Side Caps and Neutral Rocket

    Cut two Flood-Seal® caps at the appropriate ring with an approved safety cutting device and install them on the load-side of the hot cables. Apply silicone grease to ease installation. Cut one CS 2277 Flood-Seal® insulating rocket (short cover) and install it on the feed side of the neutral cable, applying silicone grease to ease installation.

  6. Crimp Feed-Side Socket Connectors

    Position the feed-side cables alongside the sockets and mark at 1/8” beyond the knurl mark (approximately 1 5/8”). Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the socket connectors onto the feed-side conductors with a 5/8 or equivalent die shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8” apart (five crimps with a 5/8 die).

  7. Crimp Load-Side Pin Connectors

    Position the load-side cables alongside the pins and mark at 1/8” beyond the knurl mark (approximately 1 5/8”). Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the pin connectors onto the load-side conductors with a 5/8 or equivalent die shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8” apart (five crimps with a 5/8 die).

  8. Connect Neutral and Insulate

    Insert the Neutral Pin into the Neutral Socket. Slide the Flood Seal® Insulating Rocket down over the mated connector to provide insulation.

  9. Connect First Hot Load-Side

    Insert one Hot Load-Side Pin into a Hot Feed-Side Socket. Slide the cover and cap together to secure the connection.

  10. Connect Remaining Hot Load-Side

    Repeat the connection process from Step 9 for the other hot feed-side.

  11. Reconnect Power

    Reconnect the transformer or feed. WARNING: Connection to the service may be made with the contact block energized, but it must not be under load.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.