ABB - Installation Products SS1 2/0 FN 500K - Disconnect Kit - Conductor Size 2/0, Full Neutral, 500 Pound Break Force

ABB Installation Products SS1 2/0 FN 500K Disconnect Kit - Conductor Size 2/0, Full Neutral, 500 Pound Break Force

UPC: 783786801947


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 24

Multiplier: 24

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB SS1 2/0 FN 500K disconnect kit provides a reliable, high-force disconnection solution for industrial electrical systems. The kit includes two sockets, one neutral socket, two pin terminals, one neutral pin terminal, one SSL link kit (breakaway link and bail), two Flood-Seal insulating splice covers, and one Flood-Seal insulating rocket. Engineered for durability, the SS1 series supports efficient maintenance and troubleshooting by offering a clear physical break point in electrical circuits. Ideal for panelboards, switchgear, and distribution systems, this kit meets industrial standards for safety and performance. The full-neutral design accommodates grounding requirements, while the 500 lb break force ensures reliable operation under significant load conditions. Compatible with standard 2/0 conductors, it integrates seamlessly into existing ABB systems or other industrial setups requiring robust disconnection solutions.
  • Full-neutral configuration for grounding compliance
  • 500-pound break force for secure power isolation
  • Includes sockets, pin terminals, and Flood-Seal insulating components
  • Compatible with ABB safety switches and industrial systems

Specifications

Application
Service Entrance Disconnects
Insulation
Yes
Material
Aluminum
Special Features
Full Neutral Assembly. 500 Pound Break Force
Standard
ANSI C119.4-2004
Type
Storm-Safe Breakaway Service Entrance Kits - Single Service
Wire Size
2/0 AWG
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.4600 L
Package Weight (Metric)
0.6620 kg
Aluminum Pedestal Hub Connector, 2/0 Stranded, Aluminum and Copper. 6-Sided Hub with Welded Splice attached. 2.5 inch wide x 2.165 inch tall x 1.187 inch thick. Includes 6 Screws. 0.91 inch Diameter hole through Center - with (6) 1/2-13 UNC-2B on each Side. Splice is 2.5 inch long with Bore .477 inch Diameter x 1.435 inch Deep. Die TX 76 249 840 11A. Includes Compound and Gray Cap.

APH 2/0

Aluminum Pedestal Hub Connector, 2/0 Stranded, Aluminum and Copper. 6-Sided Hub with Welded Splice attached. 2.5 inch wide x 2.165 inch tall x 1.187 inch thick. Includes 6 Screws. 0.91 inch Diameter hole through Center - with (6) 1/2-13 UNC-2B on each Side. Splice is 2.5 inch long with Bore .477 inch Diameter x 1.435 inch Deep. Die TX 76 249 840 11A. Includes Compound and Gray Cap.
Storm-Safe Pin Kit - Conductor Range 2/0, Full Neutral, breakaway force - 500 Pound Break Force

SSP 2/0 FN 500K

Storm-Safe Pin Kit - Conductor Range 2/0, Full Neutral, breakaway force - 500 Pound Break Force
Disconnect Kit - Conductor Size 2/0, Reduced Neutral, 500 Pound Break Force

SS1 2/0 RN 500K

Disconnect Kit - Conductor Size 2/0, Reduced Neutral, 500 Pound Break Force
Non-Insulated Female Disconnect, Length .64 Inches, Width .23 Inches, Tab Size .187x.020, Wire Range #16-#14 AWG, Copper, Tin Plated, 1,000 Pack

BD182

Non-Insulated Female Disconnect, Length .64 Inches, Width .23 Inches, Tab Size .187x.020, Wire Range #16-#14 AWG, Copper, Tin Plated, 1,000 Pack
Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar cable range 12-350, length 3 in, width 2-1/2 in, boot no. FB 33, outlets 6

ABC 350-33

Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar cable range 12-350, length 3 in, width 2-1/2 in, boot no. FB 33, outlets 6
Aluminum Set-Screw Bar Pedestal Connectors - Single-Line Bar, cable range 6-250, length 3-7/16 inch, outlets 4, Uses Boot number BB 10 - order separately.

ABC 440

Aluminum Set-Screw Bar Pedestal Connectors - Single-Line Bar, cable range 6-250, length 3-7/16 inch, outlets 4, Uses Boot number BB 10 - order separately.
Aluminum Set-Screw Bar Pedestal Connectors - Single-Line Bar, cable range 6-500, length 4-1/16 inch, outlets 4, Uses Boot number BB 11 - order separately.

ABC 4500

Aluminum Set-Screw Bar Pedestal Connectors - Single-Line Bar, cable range 6-500, length 4-1/16 inch, outlets 4, Uses Boot number BB 11 - order separately.
Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar cable range 6-500, length 3-1/16 in, width 2-3/4 in, boot no. FB 33, outlets 6

ABC 500-33

Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar cable range 6-500, length 3-1/16 in, width 2-3/4 in, boot no. FB 33, outlets 6

Frequently Asked Questions

What conductor size does this kit support?

This kit is designed for 2/0 AWG conductors as specified in the product catalog.

Is this kit compatible with ABB SS1 series?

Yes, this kit is part of the ABB SS1 series and is designed for use with compatible ABB components.

Does this kit include a neutral conductor?

Yes, this is a full neutral disconnect kit, supporting grounding requirements.

How to Install the SS1 Series Service Entrance Disconnect System

This guide provides step-by-step instructions for the safe installation and wiring of the SS1 Series Service Entrance Disconnect System. It covers disconnecting power, preparing cables, installing insulation, crimping connectors, and making final connections. WARNING: Installation must be performed by trained installers following all applicable electrical codes and safety rules. Insulated gloves are required.

Estimated time: 2h

Tools needed:

Approved safety cutting device, Crimping tool (with 5/8 or equivalent die), Wire strippers, Measuring tape or ruler

Supplies needed:

SS1 Series Service Entrance Disconnect System kit, Breakaway link, Flood-Seal® caps (CS 2277, CSN 2277), Silicone grease, Insulated gloves (rated to appropriate voltage), Service cables (hot and neutral)

  1. Disconnect Power and Secure Service Drop

    Disconnect the power cables from the transformer or feed and secure the service drop. Follow standard safety practices when working on energized circuits. Ensure insulated gloves rated to the appropriate voltage are worn when installing on live conductors.

  2. Install Neutral Breakaway Link

    Open the neutral wedge clamp and install the breakaway link between the wedge clamp and the pole hardware. Tighten the service drop as required.

  3. Prepare Service Cables

    Cut the service cables from the transformer or feed. Trim the load-side cables so that the neutral is 6 to 12 inches longer than the hot (energized) cables. This ensures the neutral disconnects last in a storm event.

  4. Install Hot Cable Insulating Rockets (Feed-Side)

    Cut two CSN 2277 Flood-Seal® Insulating rockets (long covers) at the appropriate ring using an approved safety cutting device. Install these rockets on the feed side of the hot cables. Apply silicone grease to the cables to ease installation.

  5. Install Neutral Insulating Rocket (Feed-Side) and Hot Cable Caps (Load-Side)

    Cut two Flood-Seal® caps at the appropriate ring and install them on the load-side of the hot cables, applying silicone grease. Cut one CS 2277 Flood-Seal® insulating rocket (short cover) and install it on the feed side of the neutral cable, applying silicone grease.

  6. Crimp Feed-Side Socket Connectors

    Position the feed-side cables alongside the sockets and mark at 1/8 inch beyond the knurl mark (approximately 1 5/8 inches). Mark and strip the cable. Determine which is the neutral socket. Crimp the socket connectors onto the feed-side conductors with a 5/8 or equivalent die, filling the crimp body between the knurl marks with five crimps spaced 1/8 inch apart.

  7. Crimp Load-Side Pin Connectors

    Position the load-side cables alongside the pins and mark at 1/8 inch beyond the knurl mark (approximately 1 5/8 inches). Mark and strip the cable. Determine which is the neutral socket. Crimp the pin connectors onto the load-side conductors with a 5/8 or equivalent die, filling the crimp body between the knurl marks with five crimps spaced 1/8 inch apart.

  8. Connect Neutral

    Insert the Neutral Pin into the Neutral Socket. Slide the Flood Seal® Insulating Rocket down over the mated connector to seal it.

  9. Connect Hot Load-Side to Feed-Side

    Insert one Hot Load-Side Pin into a Hot Feed-Side Socket. Slide the cover and cap together to secure the connection.

  10. Repeat Hot Connection

    Repeat Step 9 for the other hot feed-side connection.

  11. Reconnect Power

    Reconnect the transformer or feed. Ensure the connection to the service is not under load if the contact block is energized.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.