
ABB Installation Products SS1 1/0 FN 500K Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral…
UPC: 783786753444
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Triplex block configuration for 1/0, 1/0, 1/0 ACSR conductors
- Full neutral assembly for complete electrical functionality
- 500-pound break force for controlled failure and damage mitigation
- Includes sockets, pin terminals, SSL link kit, and Flood-Seal insulating components
- Designed for utility and residential service entrance installations
Specifications
Application | Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises |
Connection Type | Triplex Block |
Insulation | Yes |
Material | ACSR |
Series | Storm-Safe Breakaway Service Entrance Kits |
Size | 1/0 |
Special Features | Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts |
Type | Storm-Safe Service Entrance Disconnect Pin Kits |
Wire Size | 1/0 ACSR AWG |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

SSP 1/0 FN 750K
Storm-Safe Pin Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 pounds break force
SS1 2 FN 500K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
SS1 2 FN 750K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
SS1 1/0 RN 500K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,2, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
SS1 2 RN 500K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
SS1 4 FN 500K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
SS1 4 FN 750K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
SS1 4 RN 500K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,6, neutral assembly - reduced neutral, breakaway force - 500 Pound Break ForceFrequently Asked Questions
How does Storm-Safe improve safety during power line breaks?
Lines come down de-energized, avoiding safety hazards for the public and utility crews. They also come down at the pole, preventing damage to customer premises and utility equipment.
What conductors are used with SS1 1/0 FN 500 K?
The SS1 1/0 FN 500 K kit uses 1/0, 1/0, 1/0 ACSR for the triple block and has a full neutral assembly.
What components are included in an SSP pin kit?
An SSP pin kit includes two pin terminals, one neutral pin terminal, an SSL link kit (breakaway link and bail), and two Flood-Seal insulating rockets.
What additional kits are needed for multi-service base kits?
The SS 2 K two-service base kit requires two SSP pin kits, and the SS 3 K three-service base kit requires three SSP pin kits.
What is included in a multi-service base kit?
Multi-service base kits include one contact block, one U-bolt, two Flood-Seal insulating rockets, and three 1/2"-13 bolts.
What is the breakaway force for SS1 1/0 FN 500 K?
The SS1 1/0 FN 500 K single-service kit has a breakaway force of 500 lbs.
What breakaway forces are available for SSL Link Kits?
SSL Link Kits are available with breakaway forces of 500 lbs and 750 lbs.
What specifications does the Storm-Safe system meet?
The Blackburn Storm-Safe service entrance breakaway disconnect system meets ANSI C119.4-2004 specifications.
What conductor types are compatible with Storm-Safe?
The system is dual rated for use with both aluminum and copper conductors.
How does Storm-Safe protect against moisture?
An internal O-ring prevents moisture into the contact, and external Flood-Seal insulating rockets seal the entire system from the elements.
How to Install the SS1 Series Service Entrance Disconnect System
This guide provides step-by-step instructions for the safe installation and wiring of the SS1 Series Single Service Kit, including cable preparation and connector assembly. Adhere to all safety warnings.
Estimated time: 1h 30m
Tools needed:
Approved safety cutting device, Crimp tool (with 5/8 die or equivalent), Insulated gloves (rated to appropriate voltage)
Supplies needed:
Breakaway link, Flood-Seal® caps, CS 2277 Flood-Seal® insulating rocket (short cover), CSN 2277 Flood-Seal® Insulating rockets (long covers), Pin connectors, Socket connectors, Silicone grease
- Disconnect Power and Secure Service Drop
Disconnect the power cables from the transformer or feed. Secure the service drop to prevent accidental re-energization. WARNING: Danger of Electric Shock! Ensure all power is off and follow standard safety practices when working on circuits. Wear insulated gloves rated to the appropriate voltage.
- Install Neutral Breakaway Link
Open the neutral wedge clamp. Install the breakaway link between the wedge clamp and the pole hardware. Tighten the service drop as required to ensure a secure connection.
- Prepare Service Cables
Cut the service cables from the transformer or feed. Trim the load-side cables, ensuring the neutral cable is 6 to 12 inches longer than the hot (energized) cables. This length difference helps ensure the neutral disconnects last in a storm event.
- Install Hot Feed-Side Insulating Covers
Using an approved safety cutting device, cut two CSN 2277 Flood-Seal® Insulating rockets (long covers) at the appropriate ring. Apply silicone grease to the hot feed-side cables to ease installation, then install these covers onto the hot feed-side cables.
- Install Hot Load-Side Caps and Neutral Feed-Side Cover
Cut two Flood-Seal® caps at the appropriate ring with an approved safety cutting device. Apply silicone grease to the hot load-side cables and install these caps. Separately, cut one CS 2277 Flood-Seal® insulating rocket (short cover) and apply silicone grease to the neutral feed-side cable before installing this cover.
- Crimp Feed-Side Socket Connectors
Position the feed-side cables alongside the socket connectors. Mark the cables at approximately 1 5/8 inches (1/8 inch beyond the knurl mark). Strip the marked section of the cable. Identify the neutral socket. Crimp the socket connectors onto the feed-side conductors using a crimp tool with a 5/8 die or equivalent. Ensure the crimp body is filled between the knurl marks with five crimps spaced 1/8 inch apart.
- Crimp Load-Side Pin Connectors
Position the load-side cables alongside the pin connectors. Mark the cables at approximately 1 5/8 inches (1/8 inch beyond the knurl mark). Strip the marked section of the cable. Identify the neutral socket. Crimp the pin connectors onto the load-side conductors using a crimp tool with a 5/8 die or equivalent. Ensure the crimp body is filled between the knurl marks with five crimps spaced 1/8 inch apart.
- Connect Neutral Pin and Socket
Carefully insert the Neutral Pin into the Neutral Socket. Slide the Flood Seal® Insulating Rocket down over the mated connector to secure and insulate the connection.
- Connect Hot Load-Side Pin to Hot Feed-Side Socket
Insert one Hot Load-Side Pin into a Hot Feed-Side Socket. Slide the corresponding cover and cap together over the connection to ensure proper insulation and sealing.
- Repeat Hot Connection for Second Feed-Side
Repeat the process from Step 9 for the other hot feed-side connection, ensuring the second Hot Load-Side Pin is securely inserted into its respective Hot Feed-Side Socket, and the cover and cap are slid together.
- Reconnect Power
Reconnect the transformer or feed. Ensure all connections are secure and properly insulated before re-energizing the circuit. WARNING: Connection to the service may be made with the contact block energized, but it must not be under load.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.