ABB - Installation Products RRK 10 HS - Aluminum Heat-Shrink Compression Splice Kits, wire range 1/0, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Yellow. For Aluminum Conductors Only.

ABB Installation Products RRK 10 HS Aluminum Heat-Shrink Compression Splice Kits, wire range 1/0, connector length 3 inch…

UPC: 783786745999


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB RRK 10 HS Aluminum Heat-Shrink Compression Splice Kit provides a permanent, watertight connection for 1/0 AWG aluminum conductors in industrial and power distribution applications. Each kit includes a 3-inch aluminum compression connector and a 5.5-inch heat-shrink insulator, ensuring full insulation coverage and mechanical integrity. The splice kit uses five 5/8-inch dies for uniform compression, delivering a secure joint that resists vibration and environmental stress. Designed exclusively for aluminum conductors, the integrated heat-shrink technology seals against moisture and contaminants, eliminating the need for separate insulation steps. The yellow color-coded system simplifies identification in multi-conductor installations, reducing installation errors and improving workflow efficiency. Typical applications include power distribution networks, industrial wiring, renewable energy systems, and commercial electrical installations where aluminum conductors are standard. The compression design ensures long-term electrical integrity by minimizing resistance and heat buildup at splice points, reducing the risk of failures in harsh or exposed environments. Each kit is optimized for compatibility with ABB’s compression tooling, including the Homac UT 3 or UT 3 M tool for wire sizes up to 4/0, ensuring consistent results across installations. The radiating rib design of the heat-shrink tubing dissipates heat and centers the watertight insulating cover, providing a fully sealed repair splice every time.
  • Permanent, watertight splice for 1/0 AWG aluminum conductors
  • 3-inch aluminum compression connector with 5.5-inch heat-shrink insulator
  • Five 5/8-inch dies for uniform compression and vibration resistance
  • Yellow color-coded system for easy identification in multi-conductor setups
  • Compatible with ABB Homac UT 3 or UT 3 M compression tools

Specifications

Application
Heat-Shrink Tubing Created Sealed, Watertight Splices
Conductor Range
1/0 AWG
Connection
Compression
Material
Aluminum
Size
Connector 3 inches, Cover 5-1/2 inches
Special Features
Heavy-Wall Heat-Shrink Tubing- Crimp the two pieces of wire together, then head the splice with a hot-air gun to get a fully sealed, watertight repair splice. Radiating Rib dissipates heat, centers the watertight insulating cover and seals perfectly every time. Prefilled with Oxide-Inhibitor to prevent oxidation and keep out moisture
Type
Compression Splice
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.1500 L
Package Weight (Metric)
0.0680 kg
Aluminum Reducing Splice Connector for Copper Wire Size 1/0, Aluminum Wire Size 3/0, Tin Plated, Die Code 60, Die Color Code Ruby

60940

Aluminum Reducing Splice Connector for Copper Wire Size 1/0, Aluminum Wire Size 3/0, Tin Plated, Die Code 60, Die Color Code Ruby
2HoleStandard BarrelAluminum Compression Lug1/0 AWG -1/2 Bolt Standard BarrelAluminum Compression Lugs is a type ofaluminum compression connector that is produced from high conductivityaluminum tubing.Center stop assures proper cable installation.They are tin-plated to provide corrosion resistance and are marked with die index and color coded for easy reference. Listed for 35KV maximum when properly installed.

AL1/0N

2HoleStandard BarrelAluminum Compression Lug1/0 AWG -1/2 Bolt Standard BarrelAluminum Compression Lugs is a type ofaluminum compression connector that is produced from high conductivityaluminum tubing.Center stop assures proper cable installation.They are tin-plated to provide corrosion resistance and are marked with die index and color coded for easy reference. Listed for 35KV maximum when properly installed.
Splicer/Reducer, dual rated for use with copper or aluminum conductors, clear insulation, 350 kcmil - #10 SOL.

PISR350-1

Splicer/Reducer, dual rated for use with copper or aluminum conductors, clear insulation, 350 kcmil - #10 SOL.
Aluminum Flood-Seal Compression Splice Kits, wire range 2, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Yellow/Red. For Aluminum Conductors Only.

RRK 102

Aluminum Flood-Seal Compression Splice Kits, wire range 2, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Yellow/Red. For Aluminum Conductors Only.
Aluminum Flood-Seal Compression Splice Kits, wire range 2, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Red. For Aluminum Conductors Only.

RRK 2

Aluminum Flood-Seal Compression Splice Kits, wire range 2, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Red. For Aluminum Conductors Only.
Aluminum Flood-Seal Compression Splice Kits, wire range 2/0, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Gray. For Aluminum Conductors Only.

RRK 20

Aluminum Flood-Seal Compression Splice Kits, wire range 2/0, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Gray. For Aluminum Conductors Only.
Aluminum Flood-Seal Compression Splice Kits, wire range 1/0, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Yellow. For Aluminum Conductors Only.

RRK 10

Aluminum Flood-Seal Compression Splice Kits, wire range 1/0, connector length 3 inch, insulator length 5-1/2 inch, dies 5/8 (5), color code Yellow. For Aluminum Conductors Only.
Aluminum Flood-Seal Compression Splice Kits, wire range 250, connector length 4-1/2 inch, insulator length 7-1/2 inch, dies 840,249,11A, no color code. For Aluminum Conductors Only.

RRK 250

Aluminum Flood-Seal Compression Splice Kits, wire range 250, connector length 4-1/2 inch, insulator length 7-1/2 inch, dies 840,249,11A, no color code. For Aluminum Conductors Only.

How to Install a Heat-Shrink Compression Splice Kit

This guide provides step-by-step instructions for installing a heat-shrink compression splice kit, covering cable preparation, connector crimping, and heat-shrink application. Always disconnect power before installation and ensure the work is performed by a qualified electrician following national and local electrical codes. Wear safety glasses and protective gloves.

Estimated time: 20m

Tools needed:

Wire strippers, Wire brush, Crimping tool, Heat torch, Safety glasses, Protective gloves

Supplies needed:

Heat-shrink tubing, Compression connector, Oxide inhibitor (for aluminum cable)

  1. Strip Cable Insulation

    Strip both ends of the cable insulation to half the length of the connector plus 1/4 inch, as shown in Figure 1.

  2. Clean Cable Insulation

    Thoroughly clean the stripped cable insulation.

  3. Position Heat-Shrink Tubing

    Carefully place the heat-shrink tubing over one of the clean cable ends. Protect the tubing from potential damage by the conductor as it slides over the cable end, as illustrated in Figure 2.

  4. Prepare Conductor Strands

    Wire brush the conductor strands. If working with aluminum conductors, apply oxide inhibitor and wire brush it thoroughly into the strands.

  5. Install and Crimp Connector

    Install the compression connector onto the prepared conductors. Crimp the connector using the recommended die size marked on the connector. After crimping, clean and deburr the connector if necessary, as shown in Figure 3.

  6. Shrink Heat-Shrink Tubing

    Center the heat-shrink tubing over the splice and hold it in place. Using a heat torch, apply the outer 3-4 inch tip of the flame to the heat-shrinkable material with a rapid, brushing motion. Keep the flame moving to prevent scorching. Begin shrinking at the center of the tube, working the flame smoothly around all sides to apply uniform heat (a). Once the center is shrunk, work the torch towards one end (b), then to the opposite end (c) until the tubing is completely shrunk, as depicted in Figure 4.

  7. Inspect Splice

    Inspect the completed splice. The properly installed tube should be smooth and conform tightly to the connection, with adhesive visible at both ends. Reheat any flat spots or wrinkles to ensure a complete seal. Allow the installation to cool completely before touching, moving, or placing it into service.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.