ABB Installation Products R2T15J2-T0270 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38…
UPC: 783786561315
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV outdoor application rating
- Suitable for Concentric Neural (CN) and Jacketed Concentric Neutral (JCN) cables
- Accommodates cable insulation diameters from 0.84" to 1.38"
- Includes Universal Aluminum Barrel for AL or CU conductors
- Comes with a copper wire lead for reliable connection
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 4/0 AWG , 250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T15J2-N0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 /Compact or Solid 250.
R2T15J4-N0380
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 750 kcmil Stranded or 900 kcmil Solid
R2T15J2-T0240
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0/ Compact or Solid 2/0.
R2T15J2-T1270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed 4/0/ Compact or Solid 250.
R2T15J1-T0260
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 3/0 /Compact or Solid 4/0.
R2T35J4N0230
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
R2T35J4N0270
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
R2T35J4-N0380
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900Frequently Asked Questions
What power system frequency does the R2T15 support?
The R2T15 termination supports a power system frequency range of 48 to 62 Hz.
What is the maximum altitude for R2T15 operation?
The maximum altitude for operating the R2T15 termination is 3300 feet (1005 m).
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
What cable types are compatible with R2T terminations?
R2T terminations accommodate popular XLP and EPR cable types and various shield constructions.
What cable sizes does the R2T termination cover?
The R2T termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.
What is the operating ambient temperature range?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T15 termination?
The R2T15 outdoor cable termination has a voltage rating of 15 kV.
What cable types are compatible with R2T terminations?
R2T terminations accommodate popular XLP and EPR cable types and various shield constructions.
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
What power system frequency does the R2T15 support?
The R2T15 termination supports a power system frequency range of 48 to 62 Hz.
How to Install the 15kV Ranger 2 Cable Termination (R2T15J2)
This guide provides step-by-step instructions for the safe and proper installation of the 15kV Ranger 2 Cable Termination (R2T15J2) for indoor/outdoor applications on concentric and jacketed concentric neutral cables. Ensure all apparatus are de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Solvent applicator (e.g., clean cloth), Gloves
Supplies needed:
Silicone Rubber Termination (R2T15J2), Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Approved solvent, Vinyl tape or binding wire, Connector or Lug (compatible with cable), Silicone grease, Aluminum oxide abrasive (grit 120 or finer, if needed)
- Prepare the Cable for Termination
Before starting, ensure the cable size fits within the kit range. Train the cable into its final position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable according to the specified dimensions for the cable jacket, mastic, neutral wires, semi-conductor, and conductor length, accounting for the terminal lug depth and any growth during crimping of aluminum lugs. For concentric neutral cables, bend the neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire.
- Apply Mastic Seals to Cable Jacket
Using a 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position the mastic precisely as it serves as a marker for the terminator; cut it flush without overlapping. Next, apply a second mastic band over the neutral wires (if applicable) and the previously applied mastic, again using a 50% stretch and cutting flush without overlapping. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension from the jacket end.
- Install the Lug or Connector
If using a lug or connector that will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug onto the prepared conductor and crimp it according to the manufacturer's directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation thoroughly with an approved solvent. Exercise caution to prevent the solvent from touching the semi-conductor insulation shield. If an abrasive is necessary, use it only on the insulation, not the semi-conductor shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
First, create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, do not exceed two layers of tape. If the barrel diameter is smaller, build up the tape to match the insulation diameter. Next, cover the edge of the semi-conductor insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body is firmly butted against the leading edge of the mastic seal and avoid pushing or pulling the termination assembly during core removal.
- Complete Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid lubricating the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Finally, twist the concentric neutral wires together and connect them securely to the system ground. Confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.