ABB - Installation Products LTTUS01B-C - Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

ABB Installation Products LTTUS01B-C Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core…

UPC: 786210223513


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB LTTUS01B-C is a Liquid Tight Flexible Metallic Conduit designed for reliable wire and cable protection across a broad operational temperature range. Constructed with a galvanized steel core for mechanical strength and durability, it is further protected by a robust PVC jacket. This conduit is rated for working temperatures from -55°C to 105°C, making it suitable for applications exposed to extreme cold or elevated heat. The 3/8 inch trade size offers flexibility for various wiring configurations. Each unit measures 30 meters (100 feet) in length, providing ample material for extensive installations. This product holds UL E125517 and CSA LR-72635 certifications, confirming its compliance with established safety and performance standards. Furthermore, it adheres to RoHS regulations, indicating its compliance with environmental directives regarding hazardous substances. The black color of the conduit aids in identification and installation management. ABB Installation Products is the manufacturer of this specific model, SKU LTTUS01B-C. Its UNSPSC code is 39131706. This conduit is engineered to maintain the integrity of electrical systems in environments where temperature fluctuations are a significant factor, ensuring consistent protection for conductors.
  • Galvanized Steel Core with PVC Jacket for durability
  • Wide Working Temperature Range: -55°C to 105°C
  • 3/8 Inch Trade Size Conduit
  • Length: 30 Meters / 100 Feet
  • UL E125517 & CSA LR-72635 Certified, RoHS Compliant

Specifications

Application
Used with high temperature machine tool wiring
Color
Black
Finish
PVC Jacket
Inside Diameter
0.484 in
Inside Diameter
12.2936 mm
Length
100 in
Length
2540 mm
Material
Galvanised Steel Core with PVC Jacket
Material Quality
Galvanised Steel
Outside Diameter
0.71 in
Outside Diameter
18.034 mm
Radius
2.0079 in
Radius
51 mm
Series
LTTUS
Size
3/8 Inch
Special Features
Global certification to UL, CSA and IEC standards requirements
Standard
UL E125517, CSA LR-72635, RoHS
Trade Size
3/8 in
Type
Liquid Tight Flexible Metallic Conduit
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.2900 L
Package Weight (Metric)
0.1320 kg
Low Fire Hazard, Medium Flexibility Conduit, 3/8 Inch, Nominal Conduit Size 16mm, Outside Diameter 17.0mm, Inside Diameter 13.0mm, Static Bend Radius 35mm, IP54 and IP65 Rating, Galvanised Steel Core with Low Fire Hazard Jacket, Reel Length 25 Meters, Black

LFH-SP16/25M

Low Fire Hazard, Medium Flexibility Conduit, 3/8 Inch, Nominal Conduit Size 16mm, Outside Diameter 17.0mm, Inside Diameter 13.0mm, Static Bend Radius 35mm, IP54 and IP65 Rating, Galvanised Steel Core with Low Fire Hazard Jacket, Reel Length 25 Meters, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS03B-C

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS07B-B

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS08B-A

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS04B-C

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS09B-A

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS05B-B

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTTUS02B-C

Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

Frequently Asked Questions

What is the purpose of this chemical resistance guide?

This guide provides chemical resistance ratings for flexible metallic conduit materials, including PVC, PU, and Type LTXE thermoplastic rubber jacket.

What do the chemical resistance ratings A, B, C, D signify?

The chemical resistance ratings signify: A – Excellent to Good, B – Good to Fair, C – Fair to Limited, and D – Unsatisfactory.

Which materials are covered in this chemical resistance guide?

This chemical resistance guide covers PVC (Polyvinyl Chloride), PU (Polyurethane), and Type LTXE thermoplastic rubber jacket materials.

Is the chemical resistance information guaranteed for end-product applications?

No, this information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.

How should chemical resistance be verified for specific applications?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations to verify chemical resistance.

What is the purpose of this chemical resistance guide?

This guide provides chemical resistance ratings for flexible metallic conduit materials, including PVC, PU, and Type LTXE thermoplastic rubber jacket.

What do the chemical resistance ratings A, B, C, D signify?

The chemical resistance ratings signify: A – Excellent to Good, B – Good to Fair, C – Fair to Limited, and D – Unsatisfactory.

Which materials are covered in this chemical resistance guide?

This chemical resistance guide covers PVC (Polyvinyl Chloride), PU (Polyurethane), and Type LTXE thermoplastic rubber jacket materials.

Is the chemical resistance information guaranteed for end-product applications?

No, this information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.

How should chemical resistance be verified for specific applications?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations to verify chemical resistance.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.