ABB Installation Products LTTUS05B-B Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core…
UPC: 786210223551
Documents & Media
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 1-1/4" conduit size with 15m (50ft) length
- Galvanized steel core for crush resistance and PVC jacket for liquid-tight sealing
- Operating temperature range: -55°C to 105°C
- UL E125517 and CSA LR-72635 certified for North American compliance
- RoHS compliant, black color for UV resistance and heat dissipation
Specifications
Application | Used with high temperature machine tool wiring |
Color | Black |
Finish | PVC Jacket |
Inside Diameter | 1.38 in |
Inside Diameter | 35.052 mm |
Length | 50 in |
Length | 1270 mm |
Material Quality | Galvanised Steel |
Outside Diameter | 1.66 in |
Outside Diameter | 42.164 mm |
Radius | 7.0079 in |
Radius | 178 mm |
Special Features | Global certification to UL, CSA and IEC standards requirements |
Standard | UL E125517, CSA LR-72635, RoHS |
Trade Size | 1-1/4 in |
Type | Liquid Tight Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0200 L |
Package Weight (Metric) | 0.4630 kg |

LTTUS02B-C
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS07B-C
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS11B-A
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS01B-K
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS01B-L
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS02B-K
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS02B-L
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, BlackFrequently Asked Questions
Is the chemical resistance data guaranteed for all applications?
No, the information is a guideline only, and no guarantee is implied. Results are from laboratory tests, not installed end-product applications.
What is recommended for extreme or unusual chemical exposure conditions?
ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations, as laboratory tests may not reflect end-product applications.
What do the chemical resistance ratings A, B, C, D mean?
The ratings indicate: A-Excellent to Good, B-Good to Fair, C-Fair to Limited, and D-Unsatisfactory. These apply to PVC and Polyurethane (PU).
Is the chemical resistance data guaranteed for all applications?
No, the information is a guideline only, and no guarantee is implied. Results are from laboratory tests, not installed end-product applications.
What is recommended for extreme or unusual chemical exposure conditions?
ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations, as laboratory tests may not reflect end-product applications.
What do the chemical resistance ratings A, B, C, D mean?
The ratings indicate: A-Excellent to Good, B-Good to Fair, C-Fair to Limited, and D-Unsatisfactory. These apply to PVC and Polyurethane (PU).
Is the chemical resistance data guaranteed for all applications?
No, the information is a guideline only, and no guarantee is implied. Results are from laboratory tests, not installed end-product applications.
What is recommended for extreme or unusual chemical exposure conditions?
ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations, as laboratory tests may not reflect end-product applications.
What do the chemical resistance ratings A, B, C, D mean?
The ratings indicate: A-Excellent to Good, B-Good to Fair, C-Fair to Limited, and D-Unsatisfactory. These apply to PVC and Polyurethane (PU).
How resistant is the LTXE jacket to Vegetable Oil?
The LTXE jacket shows 60% tensile strength and 70% elongation after 72 hours at 100 °C in Vegetable Oil.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.