ABB Installation Products LTTUS02B-C Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core…
UPC: 786210223520
Documents & Media
Contact for Pricing
Minimum Qty: 100
Multiplier: 100
*Contact for lower quantities*
Call (262) 252-1600 or email [email protected] for pricing and availability.
Overview
- Galvanized steel core with smooth PVC jacket for mechanical strength and corrosion resistance
- Operating temperature range: -55°C to 105°C (-67°F to 221°F)
- Copper bonding wire and tinned copper shielding braid (90%+ coverage) for EMI/RFI shielding
- Smooth inner diameter for easy wire pulling and reduced installation time
- Black PVC jacket provides UV resistance, abrasion protection, and liquid-tight performance
Specifications
Application | Used with high temperature machine tool wiring |
Color | Black |
Finish | PVC Jacket |
Inside Diameter | 0.622 in |
Inside Diameter | 15.7988 mm |
Length | 100 in |
Length | 2540 mm |
Material | Galvanised Steel Core with PVC Jacket |
Material | Galvanized Steel, PVC |
Material Quality | Galvanised Steel |
Outside Diameter | 0.84 in |
Outside Diameter | 21.336 mm |
Radius | 2.9921 in |
Radius | 76 mm |
Series | LTTUS |
Size | 1/2 Inch |
Special Features | Global certification to UL, CSA and IEC standards requirements |
Standard | UL E125517, CSA LR-72635, RoHS |
Trade Size | 1/2 in |
Type | Liquid Tight Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.3200 L |
Package Weight (Metric) | 0.1450 kg |

SPUL20/BL/50M
Liquid Tight, Medium Flexibility, Covered Steel Conduit, 1/2 Inch, Nominal Conduit Size 20mm, Outside Diameter 21.1mm, Inside Diameter 15.9mm, Static Bend Radius 80mm, Reel Length 50 Meters, UL Listed and CSA Approved, PVC Covered Galvanised Steel Core with Copper Packing, Black
LTTUS07B-C
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS11B-A
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS01B-K
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS01B-L
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS02B-K
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS02B-L
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
LTTUS04B-J
Liquid Tight Flexible Metallic Conduit, Wide Temperature Range, Galvanised Steel Core with PVC Jacket, Conduit Size 1 Inch, Length 120 Meters/400 Feet, Working Temperature -55 to 105 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, BlackFrequently Asked Questions
What is the LTXE jacket's resistance to 10W-40 Motor Oil?
After 72 hours at 100 °C, the LTXE jacket retains 50% tensile strength and 55% elongation, with a 25% volume increase.
How does the LTXE jacket perform with ASTM #2 Oil?
After 7 days at 60 °C, the LTXE jacket retains 90% tensile strength and 98% elongation when exposed to ASTM #2 Oil.
What is the LTXE jacket's resistance to Gasoline?
After 72 hours at 100 °C, the LTXE jacket retains 40% tensile strength and 35% elongation, with a 17% volume increase.
What do the chemical resistance ratings A, B, C, D mean?
A means excellent to good, B means good to fair, C means fair to limited, and D means unsatisfactory resistance for PVC and PU.
How does Ethylene Glycol affect the LTXE jacket?
After 72 hours at 100 °C, the LTXE jacket retains 95% tensile strength and 90% elongation, with a 2% volume increase.
What is the LTXE jacket's resistance to Silicon Oil?
After 72 hours at 100 °C, the LTXE jacket retains 100% tensile strength and 80% elongation, with a -14% volume increase.
How does the LTXE jacket perform with 5% Salt Water?
After 72 hours at 100 °C, the LTXE jacket retains 80% tensile strength and 100% elongation, with a 1% volume increase.
How does Transmission Oil affect the LTXE jacket?
After 72 hours at 100 °C, the LTXE jacket retains 50% tensile strength and 50% elongation, with a 32% volume increase.
What is the LTXE jacket's resistance to Freon2?
After 72 hours at 80 °C, the LTXE jacket retains 93% tensile strength and 84% elongation.
What do the chemical resistance ratings A, B, C, D mean?
A means excellent to good, B means good to fair, C means fair to limited, and D means unsatisfactory resistance for PVC and PU.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.