ABB - Installation Products K676LR-M2380 - 900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. No Sealing Kit.

ABB Installation Products K676LR-M2380 900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug…

UPC: 075114245418


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K676LR-M2380 is a 900 Amp, 15/25kV 600 Series Elbow connector designed for medium-voltage cable systems. This elbow includes an integrated test point for safe voltage verification without cable disconnection, an insulated plug and cap for environmental protection, and a copper compression lug for reliable conductor termination. The unit accommodates cable insulation diameters from 1.370 inch to 1.630 inch and supports compressed stranded conductors sized 700/750 kcmil or compacted solid conductors up to 900 kcmil. The compression lug ensures low-resistance electrical contact and mechanical integrity in high-current applications. This elbow is part of ABB’s 600 Series, a proven line of medium-voltage accessories used in utility, industrial, and commercial power distribution systems. The absence of a sealing kit simplifies installation while maintaining compliance with applicable standards for medium-voltage cable accessories. Typical applications include switchgear terminations, transformer connections, and underground distribution systems where reliable, high-current terminations are required.
  • 900 Amp rated for high-current medium-voltage applications
  • 15/25kV voltage class with integrated test point for safe voltage checks
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Supports compressed stranded 700/750 kcmil or compacted solid 900 kcmil conductors
  • Includes copper compression lug, insulated plug, cap, stud, and cable adapter

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and Equipment in a de-energized State. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655LRTP-N0380

600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K655RLR-N-0410

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656RLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655RLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 900 kcmil or Compacted Solid 1000 kcmil.

K676LR-M2400

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 900 kcmil or Compacted Solid 1000 kcmil.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K656RLR-L0360

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655RLR-N0380

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K676LR-N2410

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

Frequently Asked Questions

Does the K676LR meet any industry standards?

Yes, the K676LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the maximum operating voltage for the 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What is the continuous current rating for the K676LR?

The K676LR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What cable insulation diameters does the K676LR support?

The K676LR supports cable insulation diameters from .640 inches to 1.935 inches.

What is the BIL impulse withstand for the 28kV class?

For the 28kV voltage class, the BIL Impulse Withstand is 140kV (1.2 x 50 microsecond wave).

What is the BIL impulse withstand for the 15kV class?

For the 15kV voltage class, the BIL Impulse Withstand is 95kV (1.2 x 50 microsecond wave).

When is an ECS cable seal grounding device recommended?

An ECS cable seal grounding device is recommended when the K676LR is used on metallic tape shield or drain wire cable.

What is included in a K676LR kit?

Each kit contains an elbow connector housing, copper compression lug, copper stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

What conductor sizes are compatible with the K676LR?

The K676LR is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/675LR and K655/K675LR deadbreak elbow connectors, designed for fully shielded, submersible cable connections to high voltage apparatus.

Estimated time: 1h

Tools needed:

Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (if applicable), Lubricant (silicone), Threaded stud (if mating part not equipped), No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Waterproofing material (for cable jacket)

  1. Prepare for Installation and Safety Checks

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Verify package contents are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products. Gather all required tools and maintain a clean work environment. Ensure installation is performed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cable for Connection

    Assemble the cable in its final position, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires. Remove the outer jacket (where applicable) and prepare the cable insulation and semi-con shield according to the specific cable type and diagrams provided in the full instructions (e.g., 9-3/4", 10-3/4", 12-3/4" dimensions).

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter, being careful not to cut or nick the cable adapter or conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug according to the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-3/8 inches to 7-1/8 inches (162mm-181mm); otherwise, redo assembly.

  5. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect Elbow to Mating Product

    WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part.

  7. Connect Opposite End of Elbow (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with the mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per instructions provided.

  8. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.

  9. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device, or via an alternate method if no grounding device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  10. Perform Voltage Test (Optional but Recommended)

    Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter that is used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.