Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656RLR-K0330-S - 15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656RLR-K0330-S 15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter…

UPC: 075114299114


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Series replacement elbow connector, SKU K656RLR-K0330-S, is designed for 15-25 kV systems and operates at a 600 Amp current rating. It features an aluminum compression lug for secure and reliable electrical connections. The connector accommodates a cable insulation diameter ranging from 1.090 inches to 1.310 inches, making it suitable for a variety of medium-voltage cable sizes. Specifically, it supports compressed stranded conductors up to 500 kcmil, compacted solid conductors up to 600 kcmil, and mm² compact conductors of 250/300. The included cold-shrinkable jacket seal ensures environmental protection and proper insulation integrity after installation. This component is essential for maintaining the operational continuity of electrical distribution networks, substations, and industrial power systems where reliable termination of medium-voltage cables is critical. The aluminum construction provides excellent conductivity and corrosion resistance. ABB Installation Products is a trusted manufacturer in the electrical infrastructure sector, and this replacement elbow lug upholds their commitment to providing durable and functional components for demanding applications. Key specifications include: Voltage Rating: 15/25 kV, Current Rating: 600 A, Material: Aluminum, Cable Insulation Diameter: 1.090" - 1.310", Connection Type: Compression Lug, Series: 600 Series. The cold-shrink jacket seal is a vital feature for ensuring a watertight and electrically sound connection, preventing moisture ingress and maintaining long-term performance. This product is an ideal replacement part for existing elbow connectors or for new installations requiring robust and compliant termination solutions.
  • 15-25 kV Voltage Rating
  • 600 Amp Current Rating
  • Aluminum Compression Lug
  • Cable Insulation Diameter: 1.090" to 1.310"
  • Includes Cold-Shrinkable Jacket Seal

Specifications

Amperage Rating
600 A
Application
Used where Cable has been severed and is not long enough to reach the Elbow
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
31.56 in
Length
801.624 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Rubber. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Non-Corrosive Capacitive Test Point. S - Cold-Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Replacement Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656RLR-K0330-SG3

15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. No Sealing Kit.

K676LR-M2380

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. No Sealing Kit.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K655RLR-N-0410

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656RLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655RLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 900 kcmil or Compacted Solid 1000 kcmil.

K676LR-M2400

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 900 kcmil or Compacted Solid 1000 kcmil.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K656RLR-L0360

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

Frequently Asked Questions

What items are included in the K656RLR kit?

Each kit contains an elbow connector housing, lubricant, stud, installation instructions, replacement housing, insulating plug, cable adapter, connector, adapter retaining ring, and washer and bolt.

What is the purpose of the K656RLR replacement elbow?

The K656RLR replacement elbow is used when a cable has been severed and is too short, providing a stable connection with a bus bar and cable adapter.

What are the operating voltage limits for the 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the continuous current rating of the elbow?

The continuous current rating for the K656RLR replacement elbow is 600 Amps.

What is the impulse withstand rating for the 15kV class?

For the 15kV class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What are the operating voltage limits for the 25kV class?

For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

Can the elbow be connected while energized?

No, the elbow can only be connected or disconnected using standard hand tools and equipment when it is in a de-energized state.

How do I select the correct W code for cable insulation?

Determine the cable's insulation diameter and select the W code from the table that best straddles that diameter.

What are the available material codes for the connector?

The available material codes are 0 for Universal Aluminum, 2 for Copper, and 5 for Bi-metal. Code 0 is standard.

How do I choose the correct XXX code for conductor size?

Select the proper compression lug code from the Conductor Code Table according to the conductor size (AWG or kcmil).

How to Install the K655RLR High Voltage Connector

This guide provides step-by-step instructions for installing the K655RLR connector, designed for fully shielded connections to high voltage apparatus. It covers preparing the elbow, cable, and connecting to mating parts, ensuring a secure and safe installation.

Estimated time: 2h

Tools needed:

Hex wrench (supplied), Torque wrench (with 9/16" socket), Wire strippers, Rag, Approved safety solvent, Wire brush (for aluminum cable), Hotstick, Suitable sensing device (for voltage test), Assembly tool (650ATY or 600RRT, optional), Suitable connectors (for grounding)

Supplies needed:

K655RLR Connector Kit (Elbow, Cable Adapter, Compression Connector, Insulating Plug, Receptacle, Test Point Cap, “I” Adapter, Bolt & Washer Prepack, Retaining Ring, Lubricant, Nylon venting rod), Tape, No 14 AWG copper wire (or equivalent), Semi-con sleeve (if needed, not supplied), Silicone grease

  1. Prepare the Elbow and "I" Adapter

    DANGER: Ensure all apparatus is de-energized before starting. Remove protective caps from the elbow. Clean and lubricate the “I” adapter and the inside of the elbow with the supplied lubricant. Assemble the “I” adapter into the elbow until the spade contact bottoms inside, ensuring the flat side of the “I” contact faces away from the apparatus.

  2. Connect Elbow to Mating Apparatus

    Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (if supplied) into the mating part if it's not already equipped. Clean and lubricate both the elbow and the mating part. Position the elbow so the flat side on the “I” contact faces away from the apparatus. Push the elbow onto the mating part, aligning the hole in the “I” adapter lug with the stud. Clean and lubricate the mating part for the opposite end of the elbow, then insert it, engage threads, hand tighten, and torque according to its instructions. If using an insulating plug, clean and lubricate its voltage detection cap and snap it onto the elbow.

  3. Prepare the Cable for Receptacle Housing

    Slide the receptacle housing onto the cable. Holding the cable in place, cut the cable 1 3/4" from the center of the bolt hole in the “I” adapter. Remove the semi-con shield 11 1/8" from the center of the bolt hole. If the shield dimension exceeds this, restore it using a semi-con sleeve (not supplied). At a point 1" from the end of the semi-con shield, wrap two turns of tape as a marker. Bevel the end of the insulation at a 45-degree angle, approximately 1/4" back. Thoroughly clean the insulation with an approved safety solvent, wiping from the end of the cable toward the outer jacket.

  4. Install Cable Adapter and Retaining Ring

    Apply supplied lubricant sparingly along the cable and lubricate the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until its end is flush with the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter, being careful not to cut or nick the adapter or conductor. The exposed conductor should measure between 4 3/16” to 5 1/8”. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw until the wrench twists. As a check, the exposed conductor should now measure between 4 9/16” to 4 5/8”.

  5. Prepare and Crimp Compression Connector

    Remove the protective cap from the compression connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, ensuring it is fully inserted into the crimp barrel. As a pre-check, bolt the crimp connector onto the “I” Adapter and tighten to 25 ft/lbs. Properly train the cable into its final position and mark the alignment points on the retaining ring and the outside surface of the crimp connector. Remove the bolted contact from the “I” Adapter, align the marks, and crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; if it exceeds 7 1/8”, do not proceed and recheck all previous work.

  6. Complete Final Bolt Assembly

    Ensure the flat surface of the “I” Adapter aligns with the flat surface on the crimp connector with no gaps. Assemble the washers and bolt as indicated: flat washer against the spade contact, then the Belleville washer (concave side down), then the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 9/16" socket, tighten the bolt to 50 to 60 ft-lbs. Do not attempt to move or reposition any part of the assembly after the bolt is tightened.

  7. Install and Seat Receptacle Housing

    Clean and lubricate the outside of the cable adapter and the “I” adapter with the supplied lubricant. Slide the receptacle housing over the cable adapter and up to the position shown. Insert the nylon venting rod (supplied). Use either the 650ATY or 600RRT assembly tool (or your hands) to slowly slide the receptacle housing over the splice section. WARNING: If using the 600RRT tool, do not place hands on the threaded rod or guide shaft. Remove the vent rod. Remove the assembly tool and rotate the receptacle approximately 1/8” revolution clockwise then back 1/8” revolution counterclockwise to ensure it is properly seated.

  8. Ground Concentric Neutral Cable

    Connect a short length of No 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly. Gather together the concentric neutral wires. Using suitable connectors, connect the neutral wires and grounding wires together. The metallic shield of the cable must be grounded using standard utilities’ practices. If the cable is jacketed, waterproof the jacket at this point to prevent moisture from entering under the cable jacket.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.