ABB - Installation Products K676LR-H2300 - 15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 350 Stranded/Compressed.

ABB Installation Products K676LR-H2300 15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud…

UPC: 075114307703


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K676LR-H2300 is a 15/25kV, 900 Amp DeadBreak Elbow connector engineered for medium-voltage power distribution systems. This fully shielded and submersible elbow connector features a built-in test point, enabling safe circuit testing without system de-energization. The K676LR-H2300 accommodates cable insulation diameters from 0.850 to 1.050 inches, ensuring compatibility with a wide range of medium-voltage cables. Constructed with a copper compression lug rated for 350 kcmil stranded/compressed conductors, this DeadBreak connector delivers a secure, low-resistance connection critical for high-current applications. The integrated test point simplifies maintenance procedures by allowing voltage verification while the system remains operational, reducing downtime and enhancing safety. Included components—insulated plug, cap, stud, and cable adapter—provide a complete installation-ready solution. The K676LR-H2300 is designed for use in substations, utility distribution networks, and industrial power systems where reliable medium-voltage connections are essential. Its robust construction meets stringent electrical standards for medium-voltage applications, ensuring long-term performance in demanding environments. Key specifications include a 15/25kV voltage rating, 900 Amp current capacity, and compatibility with 350 kcmil conductors. The DeadBreak design eliminates the need for load interruption during installation or testing, making it ideal for critical power distribution infrastructure.
  • 15/25kV voltage rating with 900 Amp current capacity
  • DeadBreak design allows testing without de-energizing the system
  • Copper compression lug for 350 kcmil stranded/compressed conductors
  • Cable insulation compatibility: 0.850–1.050 inches
  • Includes insulated plug, cap, stud, and cable adapter for complete installation

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Cable Insulation Diameter
0.850-1.050 inches
Color
Black
Conductor Range
350 kcmil , 400 kcmil
Conductor Size
350 Stranded/Compressed
Connection
Compression
Connection Type
Deadbreak Elbow with Test Point
Current Rating
900 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Lug Type
Copper Compression Lug
Material
Housing - EPDM-Rubber
Series
K676LR
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and Equipment in a de-energized State. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 150.

656CETP-J5300

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 150.
200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes an aluminum compression lug.

K151LY-B1230

200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes an aluminum compression lug.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-H2320-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.575 inch to 0.740 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Includes a 01300X universal aluminum compression lug. 200ECS Jacket Seal Included

K151LY-A0220-S

200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.575 inch to 0.740 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Includes a 01300X universal aluminum compression lug. 200ECS Jacket Seal Included
200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1. Includes an Aluminum compression lug.

K151LY-B1220

200 Amp, 15/25kV, DeadBreak elbow, Locking Y Splice, Bails are not required for Locking Splices, Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1. Includes an Aluminum compression lug.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

K676LR-K2320

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
200 Amp, 15/25kV, DeadBreak elbow, Locking Splice/Repair Splice, Bails are not required for Locking Splices, When used as a repair splice, the assembled length allows 4 inches for cable replacement/repair. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes an aluminum compression lug.

K151LS-B1260

200 Amp, 15/25kV, DeadBreak elbow, Locking Splice/Repair Splice, Bails are not required for Locking Splices, When used as a repair splice, the assembled length allows 4 inches for cable replacement/repair. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes an aluminum compression lug.
15/25kV 200 Amp, Deadbreak Locking Splice / Repair Splice, Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151LS-C1240

15/25kV 200 Amp, Deadbreak Locking Splice / Repair Splice, Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

Does the K676LR have a test point?

Yes, the K676LR features a non-corrosive, capacitive test point.

What is the K676LR elbow connector used for?

The K676LR elbow connector provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What conductor sizes are compatible with K676LR?

The K676LR is compatible with #2 AWG to 1250 kcmil aluminum and copper conductors.

What insulation diameters does the K676LR support?

The K676LR supports cable insulation diameters ranging from 0.640 inches to 1.935 inches.

What standard does the K676LR meet?

The K676LR meets ANSI/IEEE Standard 386, Latest Revision.

What are the 15kV operating voltage limits for K676LR?

For the 15kV class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase.

What is the continuous current rating for the K676LR?

The K676LR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What are the 28kV operating voltage limits for K676LR?

For the 28kV class, the maximum operating voltage is 16.2kV phase-to-ground and 28kV phase-to-phase.

Does the K676LR have a test point?

Yes, the K676LR features a non-corrosive, capacitive test point.

What are the 28kV operating voltage limits for K676LR?

For the 28kV class, the maximum operating voltage is 16.2kV phase-to-ground and 28kV phase-to-phase.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 600-ampere and 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems.

Estimated time: 2h

Tools needed:

Wire strippers, Wire brush, Crimping tool, Hotstick, Suitable sensing device for capacitive test points, Torque wrench

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (if applicable), Lubricant, Threaded stud (if mating part not equipped), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable connector for grounding wire, Silicone lubricant

  1. Prepare the Cable and Work Area

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all components for damage, rating, and compatibility. Position the cable with enough slack to allow for elbow removal. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm).

  2. Prepare Cable Insulation and Shield

    Prepare the cable according to its specific type (e.g., concentric neutral, unishield, jacketed, non-jacketed, flat metallic tape, fabric tape, or longitudinally corrugated shield). This involves removing the outer jacket (if applicable) and preparing the cable insulation and semi-con shield to the precise dimensions specified in the product's diagrams.

  3. Install and Lubricate the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Compression Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring the exposed conductor length is between 4-1/4” and 4-9/16” (108mm-116mm). For aluminum conductors, wire brush the conductor immediately before insertion. Fully insert the conductor into the compression lug. Measure the 'Check Dimension' (must be less than 6-3/8”) before crimping. Crimp the compression lug according to the instructions supplied with the lug. Wipe off all excess inhibitor from the lug and cable adapter surface. Verify the distance from the end of the compression lug to the cable adapter is 6-3/8” to 7-1/8” (162mm-181mm) after crimping.

  5. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect to Mating Products

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud. For the opposite end, clean and lubricate the mating part, insert it into the elbow, engage the threads, hand tighten, and then torque it according to the mating part's instructions.

  7. Install Insulating Plug or Voltage Detection Cap

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place.

  8. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded, either through a supplied grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  9. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can cause false readings. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.