Overview
- 900 Amp rated current for medium-voltage systems
- 25kV deadbreak design allows safe tap-offs without de-energizing
- Accommodates conductor sizes #1-300 CU or #1-300 AL
- No lugs required for simplified installation
- ABB Electrification medium-voltage distribution component
Specifications
Application | 25 kV, 900 Amps |
Color | Red |
Connection Type | Deadbreak |
Current Rating | 900 A |
Material | Copper |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Reducing Tap Well |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |
Frequently Asked Questions
What is the K675RTW's primary application?
The K675RTW permits a 200A deadbreak or loadbreak tap-off from a 900A connector.
What is the 15kV class max phase-to-phase voltage?
For the 15kV voltage class, the maximum phase-to-phase voltage is 14.4kV.
What items are included in the K675RTW kit?
Each K675RTW kit contains one reducing tap well, one tube of 82-08 lubricant, and installation instructions IS-0230.
What is the BIL rating for the 28kV class?
The 28kV voltage class has a 140kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).
What is the BIL rating for the 15kV class?
The 15kV voltage class has a 95kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).
What is the 28kV class max phase-to-phase voltage?
For the 28kV voltage class, the maximum phase-to-phase voltage is 28kV.
What is the 28kV class max phase-to-ground operating voltage?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the 15kV class max phase-to-ground operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the momentary current rating?
The momentary current rating for the K675RTW is 25kA Symmetrical for 10 cycles. This applies to both 15kV and 28kV classes.
What is the continuous current rating?
The continuous current rating for the K675RTW is 900 Amp. This applies to both 15kV and 28kV classes.
How to Install 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products
This guide provides step-by-step instructions for the safe installation and initial setup of 15/25/35kV 600/900 AMP Deadbreak Plug and Well products. Ensure all apparatus are de-energized before beginning any work.
Estimated time: 1h 30m
Tools needed:
Torque wrench, ELASTIMOLD 600SW spanner wrench (for specific plugs), Hotstick, Suitable voltage sensing device
Supplies needed:
Lubricant (supplied, do not substitute), Stud (if mating interface not equipped), Silicone lubricant
- De-energize and Inspect Components
Before beginning, ensure all apparatus are de-energized. Do not touch or move energized products in the work area. Inspect the plug or well, lubricant, and mating parts (elbow or bushing extension) for any damage, correct rating, and compatibility. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Prepare and Lubricate Components
Remove any protective caps from the plug or well product. If the 600 amp mating interface is not equipped with a stud, hand tighten the supplied stud into the 600 amp interface on the plug or well. Lubricate both the elbow and its mating part thoroughly with the supplied lubricant; do not substitute, as other lubricants may be harmful. Ensure all surfaces remain clean during this process.
- Connect Plug or Well
Carefully push the plug or well into the elbow or bushing extension. Ensure the components align correctly and engage the threads fully.
- Apply Specified Torque
Use a torque wrench to tighten the connection. For an insulating plug, apply 50 to 60 foot-pounds of torque. For a connector plug, tap plug, or tap well, use an ELASTIMOLD 600SW spanner wrench with the torque wrench, applying an indicated torque of 40 to 48 foot-pounds. Refer to special instructions IS-0915 for K651 and 750 rubber connecting plugs.
- Install Voltage Detection Cap (If Applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap with silicone lubricant. Place the cap onto the elbow and push down firmly until it snaps securely into place.
- Conduct Voltage Detection
Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury.
- Secure Voltage Test Point Cap
After voltage detection has been made, clean and lubricate the inside surface of the test point cap with silicone lubricant. Replace the cap onto the test point, ensuring it is securely seated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.