UPC: 783786645473
Contact for Pricing
Overview
- 15/25kV Voltage Rating
- 900 Amp Current Rating
- Deadbreak Connecting Plug
- ABB Installation Products Manufacturer
- Designed for Medium-Voltage Applications
Specifications
Application | 15/25 kV, 900 Amps |
Connection Type | Deadbreak |
Current Rating | 900 A |
Material | Copper |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Connecting Plug |
Voltage Rating | 15/25kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 4.5800 L |
Package Weight (Metric) | 2.0780 kg |
Frequently Asked Questions
What is the K675CP connecting plug used for?
The K675CP connecting plug is an insulated bus used to attach and connect two or more Elastimold K675LR/K676LR 900 Amp connectors.
What is the 15kV class BIL impulse withstand?
For the 15kV voltage class, the BIL impulse withstand is 95kV (1.2 x 50 microsecond wave).
How to order K675CP with a loose stud?
To order the K675CP with a loose stud, add the suffix "S" to the part number.
How to order K675CP with factory-assembled stud?
To order the K675CP with a factory-assembled stud, add "SP" to the part number.
What is the 28kV class BIL impulse withstand?
For the 28kV voltage class, the BIL impulse withstand is 140kV (1.2 x 50 microsecond wave).
What is the 28kV class max phase-to-phase voltage?
The maximum phase-to-phase voltage for the 28kV voltage class is 28kV.
What is the 28kV class max operating voltage?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the 15kV class max phase-to-phase voltage?
The maximum phase-to-phase voltage for the 15kV voltage class is 14.4kV.
What is the 15kV class max operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the momentary current rating?
The momentary current rating for the K675CP is 25kA Symmetrical for 10 cycles.
How to Install 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products
This guide provides step-by-step instructions for the safe installation and initial setup of 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products, including connection and voltage testing procedures.
Tools needed:
Torque wrench, ELASTIMOLD® 600SW spanner wrench, Hotstick, Suitable sensing device (for capacitive test points)
Supplies needed:
Plug or Well product, Lubricant (supplied, DO NOT SUBSTITUTE), HV insulated cap(s) or connector(s), Silicone lubricant, Elbow or Bushing Extension (mating part)
- Ensure Safety and Prepare for Installation
DANGER: Before beginning, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all parts for damage, proper rating, and compatibility with mating components. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Verify package contents are complete and undamaged, and all components fit correctly. Have all required tools ready and maintain cleanliness throughout the procedure.
- Prepare the Plug/Well and Mating Interface
Remove any protective caps from the plug or well product. If the 600amp mating interface is not equipped with a stud, hand tighten the stud (supplied with elbow/bushing extension) into the 600amp interface on the plug or well. Thoroughly lubricate both the elbow and its mating part with the supplied lubricant. DO NOT SUBSTITUTE with other lubricants, as they may be harmful to the products. Ensure all surfaces of the elbow and mating parts are clean before proceeding.
- Connect the Plug/Well to the Mating Part
Carefully push the plug or well product into the elbow or bushing extension. Ensure the threads engage properly as you make the connection.
- Torque Tighten the Connection
Use a torque wrench to tighten the connection. If installing an insulating plug, apply 50 to 60 foot-pounds of torque. If installing a connector plug, tap plug, or tap well, use an ELASTIMOLD® 600SW spanner wrench and apply an indicated torque of 40 to 48 foot-pounds. Refer to special instructions IS-0915 for K651 and 750 rubber connecting plugs.
- Install the Voltage Detection Cap (if applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap with silicone lubricant. Place the cap onto the elbow and push down firmly until it snaps securely into place.
- Perform Voltage Test
WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a hotstick to remove the test point cap, peeling it off at an angle rather than pulling directly in line. Test with a suitable sensing device, following its manufacturer's directions, to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination, moisture, dirt, or incorrect equipment can cause false readings. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.