ABB Installation Products K656LRTPFB-N0410 600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Fixed Bolt, Cable…
UPC: 783786246793
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Ampere continuous current rating
- 25kV operating voltage capability
- Deadbreak design for fully shielded connection
- Includes test point for voltage verification
- Accommodates cable insulation diameters from 1.515" to 1.780"
Specifications
Amperage Rating | 600 to 200 A |
Application | Connect 600 Amp interface to 200 Amp Loadbreak Tap |
Color | Black |
Conductor Range | 1000 kcmil |
Enclosure | Yes, EPDM Rubber |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Reducing Tap Plug 600 to 200 Amps. Test Point. Provides an External Visible Break by Hotstick Removal of the Elbow |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Stick Op Reducing Tap Plug Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656CYP0410P0410P041
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
655LRTP-FB-M0380
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, with Fixed Bolt. Cable Insulation Diameter 0.675 inch to 0.785 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
655LRTPFB-N5410
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, Cable Insulation Diameter 0.675 inch to 0.785 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
K655LRTP-L0330
600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K655LRTP-N0380
600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
675LRTPA3
900 Amp, 15kV, Stick-OP Loadbreak Reducing Tap Plug. 600AT assembly tool required for operation and/or installation of Stick-OP. 900 Amp rating requires copper current carrying connector compenents and copper conductor cable.
K655LRTP-P0410-DRG
600 Amp, 25kV, Stick-Op Connector Kit with Insulated Cap. Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.Frequently Asked Questions
What is the maximum operating voltage for this connector kit?
The ABB K656LRTPFB-N0410 Deadbreak Stick-Op Connector Kit is rated for 25kV operating voltage.
What is the current rating of this ABB connector kit?
This ABB connector kit has a continuous current rating of 600 Amperes.
What cable insulation diameter range does this connector kit support?
The connector kit is designed to fit cable insulation diameters ranging from 1.515 inches to 1.780 inches.
What type of lug is included in this connector kit?
This kit includes an aluminum compression lug suitable for compressed stranded conductors up to 1000 kcmil.
Does this connector kit feature a test point?
Yes, the ABB K656LRTPFB-N0410 Deadbreak Stick-Op Connector Kit includes a test point for diagnostic purposes.
How to Install K656/K676LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of K656/K676LR Deadbreak Elbow Connectors on 15kV and 25kV class systems, including cable preparation, component assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Wire brush (for aluminum conductor), Crimping tool, Hotstick, Suitable sensing device (for capacitive test points), Measuring tape or ruler
Supplies needed:
Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant, Stud prepack, Vinyl plastic tape (if applicable), Tape retainer (if applicable), Tape marker (if applicable), Ground wire (at least No. 14 AWG Copper), Suitable ground connector, Silicone grease, HV insulated cap(s) or connector(s) (if replacing shipping covers), Waterproofing material (for cable jacket)
- Perform Initial Safety Checks and Component Verification
Before starting, ensure all apparatus is de-energized. Inspect all parts for damage, correct rating, and compatibility with mating components. Verify package contents are complete and undamaged. If supplied with shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing. Have all required tools ready and maintain cleanliness throughout the procedure.
- Prepare Cable for Connection
Position the cable with sufficient slack and unwind concentric neutral wires if applicable. Cut the cable 1-3/4” (45mm) from the mating product's centerline. Clean the outer cable surface for 24” (610mm). Prepare the cable jacket and shield according to its type: remove outer jacket to 12 3/4” (324mm), fold back shield wires, or remove specific tape/corrugated shields to specified dimensions (e.g., 10 3/4” (273mm)). If using UNISHIELD or lead sheath cable, refer to 10TL adapter instructions. Remove semi-con shield to 9 3/4” (248mm) to 10 3/4” (273mm) without nicking insulation.
- Install Cable Adapter and Prepare Conductor
Bevel the cable insulation end at a 45-degree angle, approximately 1/4” (6mm) back. Clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the tape marker. Carefully remove the protruding cable insulation, cutting it even with the cable adapter end, ensuring the exposed conductor length is 4 3/8”–4 11/16” (111mm–119mm). Do not nick the cable adapter or conductor.
- Crimp Compression Lug
Insert the conductor fully into the compression lug (wire brush aluminum conductors immediately before insertion). Measure the 'Check Dimension' before crimping (must be less than 6 1/2” (165mm)). Crimp the lug according to its instructions, starting the first crimp away from the cable adapter. Wipe off excess inhibitor. Verify the distance from the lug end to the cable adapter is 6 1/2”–7 1/4” (165mm–184mm).
- Install Elbow and Prepare Mating Parts
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it stops, ensuring the adapter remains flush with the tape marker. Remove the tape marker. Remove protective caps from the elbow and mating part. If needed, hand tighten the supplied threaded stud into the mating part. Clean and lubricate both the elbow and mating part surfaces.
- Connect Elbow to Mating Parts
Push the elbow onto the primary mating part, aligning the compression lug hole with the stud. Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage threads, and hand tighten. Torque the mating part according to its specific instructions.
- Install Insulating Plug and Ground Cable Shield
If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap and snap it onto the elbow. Insert a No. 14 AWG Copper wire through the grounding eye, form a loop, and connect to ground using a suitable connector. Ensure the cable shield is grounded. Waterproof the cable jacket to prevent moisture ingress.
- Perform Voltage Test (Post-Installation)
Remove the test point cap using a hotstick, peeling it off at an angle. WARNING: Use a suitable sensing device designed for capacitive test points; do not use conventional voltage measuring equipment. Treat the elbow as energized until 'no voltage' is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.