ABB - Installation Products K656LR-F0220-SG3 - 15/25kV, 600 Amp, Elbow with Sealing Kit, With Test Point (includes Insulating Plug, Stud, Lug and Cable Adapter), Cable Insulation Diameter .640-.820 inches, Aluminum Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid

ABB Installation Products K656LR-F0220-SG3 15/25kV, 600 Amp, Elbow with Sealing Kit, With Test Point (includes Insulating Plug…

UPC: 075114315371


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-F0220-SG3 is a 15/25 kV, 600 Amp loadbreak elbow connector designed for medium-voltage cable terminations. This unit features a comprehensive sealing kit for environmental protection, a test point for safe voltage verification without de-energizing the circuit, an insulating plug, a stud, an aluminum lug, and a cable adapter. It is engineered to accommodate cable insulation diameters ranging from 0.640 to 0.820 inches. The included aluminum lug is suitable for conductor sizes of #2 stranded/compressed or #1 compact/solid. This elbow connector is a critical component for loadbreak operations in medium-voltage distribution systems, including switchgear, transformers, and pad-mounted equipment. The integrated test point enhances safety and reduces downtime during maintenance and testing procedures by allowing for non-intrusive voltage checks. The robust construction ensures reliable electrical contact and mechanical integrity in industrial, utility, and commercial applications. The K656LR-F0220-SG3 provides a complete termination solution for demanding medium-voltage power systems. The K656LR-F0220-SG3 is rated for 15/25 kV and a continuous current of 600 Amps. The sealing kit ensures a secure and environmentally resistant connection. The test point, complete with an insulating plug, stud, and lug, allows for safe and efficient voltage testing. The cable adapter is designed to facilitate proper connection to the cable. The specified cable insulation diameter range is from 0.640 to 0.820 inches. The aluminum lug is compatible with conductor sizes of #2 stranded/compressed or #1 compact/solid. This configuration makes the K656LR-F0220-SG3 suitable for a wide array of medium-voltage applications where reliable loadbreak connections are essential.
  • 15/25 kV Voltage Rating
  • 600 Amp Current Rating
  • Includes Sealing Kit, Test Point, Insulating Plug, Stud, Lug, and Cable Adapter
  • Aluminum Lug for #2 Stranded/Compressed or #1 Compact/Solid Conductors
  • Accommodates Cable Insulation Diameter: 0.640-0.820 inches

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.2100 L
Package Weight (Metric)
3.2710 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Compacted Solid #1.

K656CY-J0220

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Compacted Solid #1.
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation 1.370-1.630 inches, Bi-Metal Lug, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-M5300

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation 1.370-1.630 inches, Bi-Metal Lug, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-N0300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70.

K656LR-G0250

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold-Shrinkable Jacket Seal Included.

K656LR-H0240-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K656LR-M0300

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.

K656LR-G0240

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900.

K656LR-M0380

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900.

Frequently Asked Questions

Can the K656LR be easily connected or disconnected?

Yes, the K656LR can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

What is the maximum operating voltage for the K656LR?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR accommodate?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating of the K656LR?

The K656LR has a continuous current rating of 600 Amps.

Is a grounding device recommended when using the K656LR with metallic tape shield or drain wire cable?

Yes, an ECS cable seal grounding device for safety is highly recommended when used on metallic tape shield or drain wire cable.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for the 15kV class?

The AC one-minute withstand voltage for the 15kV voltage class is 34kV.

What is the DC fifteen-minute withstand voltage for the 28kV class?

The DC fifteen-minute withstand voltage for the 28kV voltage class is 84kV.

What is the corona extinction rating for the 15kV voltage class?

The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.

What is the momentary current rating for the K656LR?

The K656LR has a momentary current rating of 25kA Sym for 10 Cycles.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides detailed instructions for the safe and proper installation of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors, designed for fully shielded, submersible cable connections to high voltage apparatus on 15kV and 25kV class systems.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush, Crimping tool, Screwdriver, Hotstick, Suitable voltage sensing device, Suitable grounding connector

Supplies needed:

Elastimold 655/675LR or K655/K675LR Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), High-voltage cable, Mating apparatus bushing/tap plug/tap well, No. 14 AWG Copper wire (or equivalent) for grounding, Silicone lubricant

  1. Initial Safety and Inspection

    DANGER: Ensure all apparatus are de-energized before beginning installation. Do not touch or move energized products in the work area. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect the contents of the connector package to ensure all parts are complete and undamaged. Verify all components are compatible with the cable and mating products.

  2. Prepare Cable for Installation

    Assemble the cable in its final position, allowing sufficient slack for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.

  3. Cable Jacket and Shield Preparation

    Remove the outer jacket (if applicable) and prepare the cable according to the specific cable type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). Refer to the provided diagrams for precise dimensions for cable insulation, semi-con shield, and tape marker placement. If using a 20MA/21MA grounding device, 600ECS Jacket Cable Seal, or 10TL cable shield adapter, follow their respective installation instructions for cable preparation.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor Length

    Carefully remove the protruding cable insulation by cutting it even with the end of the cable adapter. Avoid cutting or nicking the cable adapter or the conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, re-do the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug following the instructions supplied with the lug. After crimping, wipe all excess inhibitor from the lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter must be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). Re-do if outside this range.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove any protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite End of Elbow

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the specific instructions provided with that mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to its specified torque.

  11. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down firmly until it snaps into place.

  12. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper wire (or equivalent ampacity) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either through a grounding device (following its instructions) or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test

    The Elastimold deadbreak elbow connector features an integral capacitance test point. To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.