- 15/25kV voltage rating
- 600 Amp continuous current rating
- DeadBreak Elbow design with integrated test point
- Cold-shrinkable seal with copper braid and constant force spring
- Accommodates cable insulation 1.090-1.310 inches, 750 MCM conductor size
Specifications
Amperage Rating | 600 A |
Application | 15/25kV, 600 Amp Deadbreak Elbow Connection |
Color | Black |
Conductor Range | 700 to 750 kcmil , 900 kcmil |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Aluminum, Copper Braid |
Material | Housing - EPDM-Rubber |
Series | K656LR |
Size | Cable Insulation 1.090-1.310 inches |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 25 kV |
Voltage Rating | 15/25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

656ETP-M0380-DRG
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
K656LR-H2270
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid
K656LR-J2240-SG3
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit
K655LR-F0210
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compacted Solid #2.
K656LR-J0240
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.
K655LR-F5220
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
K656LR-L5330-S
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.
K656LR-J0330
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.Frequently Asked Questions
What is the maximum operating voltage for the K656LR elbow connector?
For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.
What conductor sizes are compatible with the K656LR elbow connector?
The K656LR is compatible with conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the continuous current rating for this deadbreak elbow?
The K656LR deadbreak elbow has a continuous current rating of 600 Amps.
What is the range of insulation diameters supported by the K656LR?
The K656LR supports cable insulation diameters ranging from 0.640 inches to 1.935 inches.
Is a grounding device recommended when using the K656LR on certain cable types?
Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is highly recommended for safety.
Can the K656LR be connected or disconnected in energized states?
No, the K656LR can only be connected or disconnected using standard hand tools and equipment in a de-energized state.
What is the impulse withstand rating for the 28kV voltage class?
The impulse withstand rating for the 28kV voltage class is 140kV BIL for a 1.2 x 50 microsecond wave.
What is the AC one-minute withstand voltage for the 15kV class?
The AC one-minute withstand voltage for the 15kV voltage class is 34kV.
What is the AC one-minute withstand voltage for the 28kV class?
The AC one-minute withstand voltage for the 28kV voltage class is 45kV.
What is the corona extinction rating for the 15kV voltage class?
The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.
How to Install Elastimold Deadbreak Elbow Connectors (655/675LR & K655/K675LR)
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 600-ampere and 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems. It covers cable preparation, connector assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Wire brush, Hotstick, Suitable voltage sensing device, Torque wrench, Measuring tape or ruler, Cleaning cloths
Supplies needed:
Elbow connector (655/675LR or K655/K675LR), Cable adapter, Compression lug, Insulating plug (if used), Lubricant (silicone and general purpose), Threaded stud (if mating part not equipped), Grounding wire (min No. 14 AWG Copper), Suitable ground connector, Waterproofing material (for cable jacket), Tape marker, HV insulated cap(s) or connector(s)
- Prepare the Cable for Installation
DANGER: Ensure all apparatus is de-energized before starting. Inspect all parts for damage, correct rating, and compatibility with mating parts. Position the cable in its final assembled position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Prepare the cable according to its type (jacketed, non-jacketed, Unishield, etc.) by removing the outer jacket (if applicable) and preparing the cable insulation, semi-con shield, and tape marker to the specified dimensions (e.g., 9-3/4”, 10-3/4”, 12-3/4” from the end). Refer to specific instructions for grounding devices or shield adapters if used.
- Install the Cable Adapter and Prepare the Conductor
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. WARNING: Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is between 4-1/4” and 4-9/16” (108mm-116mm). If the length is outside this range, redo the assembly.
- Crimp the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension must be less than 6-3/8”. If not, redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug, ensuring the first crimp is located on the end closest to the cable adapter. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-3/8” to 7-1/8” (162mm-181mm). If not, redo the assembly.
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If it is not, reposition the cable adapter. Remove the tape marker.
- Connect Mating Products
DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part. For the opposite end of the elbow, clean and lubricate the mating part, then insert it into the elbow. Engage the threads and hand tighten. CAUTION: Torque the mating part according to its specific instructions. For 600-amp L-Kits, ensure each component is tightened to the specified torque per instructions provided. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap, then place it on the elbow and push down hard until the cap snaps into place.
- Ground the Cable and Perform Voltage Test
Insert one end of a grounding wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop. Do not damage the eye. Connect the wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device. If no grounding device is used, the shield must be grounded through an alternate method. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable. For voltage testing, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.