ABB - Installation Products K656LR-K0270-S - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 or mm2 Compact 125. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656LR-K0270-S 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786971015


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15/25kV 600 Amp Series Deadbreak Elbow (SKU: K656LR-K0270-S) is a fully shielded, dead-front cable termination solution designed for medium-voltage power distribution systems. This elbow connector provides a reliable, insulated connection for submersible applications, ensuring safe and efficient operation in high-voltage environments. Key specifications include a continuous current rating of 600 Amps at 15kV or 25kV, with a maximum phase-to-ground operating voltage of 8.3kV (15kV class) or 16.2kV (25kV class). The elbow meets ANSI/IEEE Standard 386 and offers a 95kV BIL impulse withstand rating for 15kV class applications. It accommodates cable insulation diameters from 1.090 inches to 1.310 inches and supports conductor sizes including 4/0 AWG compressed/stranded, 250 kcmil compact/solid, or 125 mm² compact conductors. The integrated test point enables safe circuit testing without de-energizing the system, while the included aluminum compression lug ensures a robust electrical connection. The cold-shrinkable jacket seal provides environmental protection and maintains connection integrity post-installation. The elbow is designed for use with metallic tape shield or drain wire cables, with an ECS cable seal grounding device recommended for optimal performance. Applications include submersible cable connections to high-voltage apparatus, such as transformers, switchgear, and other medium-voltage equipment. The fully molded rubber housing is peroxide-cured for durability, and the connector can be installed or disconnected using standard hand tools in a de-energized state. Optional accessories support visible external separation, bypass, isolation, dead-ending, grounding, and testing.
  • 600 Amp continuous current rating at 15kV or 25kV
  • Fully shielded, dead-front submersible design
  • Integrated test point for safe circuit testing without de-energization
  • Cold-shrinkable jacket seal for environmental protection
  • Compatible with cable insulation diameters 1.090" to 1.310" and conductors 4/0 AWG to 250 kcmil

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Deadbreak Elbow
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Jacket Seal Included
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid 250 or mm2 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-G-0270-SG3

15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid 250 or mm2 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.

K656LR-N5410-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.

K656LR-H0250-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.

K656LR-N0410-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.

K656LR-J0230

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.

K656LR-F5250-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LRM2380

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR handle?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this elbow connector?

The K656LR elbow connector has a continuous current rating of 600 Amps.

Is a grounding device recommended when using the K656LR with metallic tape shield or drain wire cable?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device for safety is highly recommended.

Can the K656LR be connected or disconnected in an energized state?

No, the K656LR can be easily connected or disconnected using standard hand tools and equipment only in a de-energized state.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand rating is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for the 15kV class?

The AC one-minute withstand voltage for the 15kV voltage class is 34kV.

What is the corona extinction rating for the 28kV voltage class?

The corona extinction rating for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the range of insulation diameters supported by the K656LR?

The K656LR supports insulation diameters ranging from 0.640 inches to 1.935 inches.

What is the momentary short-circuit current rating?

The momentary short-circuit current rating is 25kA Sym for 10 Cycles.

How to Install K656LR-K0270-S Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K656LR-K0270-S Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Cutting tool, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable capacitive sensing device

Supplies needed:

K656LR-K0270-S Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Lubricant, Stud Prepack), Insulating Plug (if required), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable connector for grounding wire, HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone lubricant, Waterproofing material (for cable jacket, recommended)

  1. De-energize Apparatus and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Inspect all parts for damage, verify their rating, and ensure compatibility with mating parts. Check package contents to ensure they are complete and undamaged, and confirm proper fit with the cable and/or mating products.

  2. Assemble Cable and Cut to Length

    Assemble the cable in its final position, ensuring enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires.

  4. Prepare Cable According to Type

    Follow the specific cable preparation instructions (A, B, or C) that apply to your cable type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). This involves removing the outer jacket (where applicable) and preparing the cable insulation, semi-con shield, and shield wires to the specified dimensions (e.g., 9-3/4”, 10-3/4”, 12-3/4” from the cut end).

  5. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4” – 4-9/16” (108mm-116mm). If the length is outside this range, redo the assembly.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (this dimension should be less than 6-3/8”). Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8” to 7-1/8” (162mm-181mm). If not, redo the assembly.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  9. Prepare Mating Products for Connection

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove any protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the lubricant supplied, ensuring all surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  11. Connect Opposite End Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  12. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. Proceed to the voltage test directions.

  13. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  14. Torque Components for L-Kits

    CAUTION: When constructing 600-amp L-Kits, be sure to tighten each component to the specified torque per the instructions provided.

  15. Perform Voltage Test (Remove Cap)

    Remove the test point cap from the ELASTIMOLD® deadbreak elbow connector using a hotstick. When removing the cap, PEEL OFF AT AN ANGLE rather than pulling directly in line with the test point assembly.

  16. Perform Voltage Test (Detect Voltage)

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter that is used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or use of the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.