ABB Installation Products K656CY-L0360 25kv, 600 Amps, Separable Wye Joint Splice, With Test Point, No Sealing Kit, Deadbreak…
UPC: 075114328630
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV voltage rating
- 600 Amp current rating
- Deadbreak separable wye joint splice
- Includes test point for diagnostics
- Accommodates 1.180-1.465 inch cable insulation diameter
Specifications
Amperage Rating | 600 A |
Application | Compact Design is suitable for small vaults and manholes |
Color | Black |
Conductor Range | 650 kcmil , 750 to 800 kcmil |
Connection | Compression |
Connection Type | Deadbreak |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 37.27 in |
Length | 946.658 mm |
Material | Housing - EPDM-Rubber |
Material | Aluminum |
Poles | 3P |
Series | K656CY |
Size | Cable Insulation Diameter 1.180 to 1.465 inches |
Special Features | Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Separable Wye Joint |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 25 kV |
Width | 8.12 in |
Width | 206.248 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-M0360-S
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400. 200ECS Jacket Seal Included.
K656CY-M0380-SG1
15/25kV, 600 Amp, Deadbreak Separable Wye Joint, with Test Point, with Cold Shrinkable Seal with Copper Rod and Crimp Connector. Cable Insulation Diameter Range 1.370 to 1.630 inch. Aluminum Lug, Conductor Size 700/750 Stranded/Compressed or 800/900 Solid/Compact.
K656CY-DP0599900
15/25kV, 600 Amp, Deadbreak Separable Wye Joint, with Test Point. 3 Joint Sizes, all which have Cold-Shrinkable Jacket Seal. (1) One - M0360 - Cable Insulation Diameter Range 1.370 to 1.630 inch. Aluminum Lug, Conductor Size 650 Stranded/Compressed or 750 Solid/Compact. (2) Two - L0320 - Cable Insulation Diameter Range 1.180 to 1.465 inch, Aluminum Lug, Conductor Size 450 Compressed/Stranded or 550 Solid/Compact.
K656CY(2)H0240-L0360
25kV, 600 Amps, Multi-way Connector. Three-Way. H0240-H0240-L0360. H - Cable Insulation Diameter 0.850 inch to 1.050 inch. 0 - Aluminum Compression Lug. 240 - 1/0 Stranded/compressed or 2/0 Solid/Compact. L - Cable Insulation Diameter 1.180 inch to 1.465 inch. 0 - Aluminum Compression Lug. 360 - 750 Solid/Compact.
K151SR-A0270-SG3
15 kV, 200 Amp, Deadbreak Elbow with SG3 Sealing Kit. Cable Insulation Diameter 9.575 to 0.740 inches (14.605-18.796mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
K152SR-C0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K656I-L0320
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 450 /Solid 500/550.Frequently Asked Questions
What items are included in the K656CY kit?
Each kit contains a 3-Way Bus Bar, two units of lubricant, installation instructions, and three straight receptacles.
What type of connector is the K656CY?
The K656CY is a 15/25kV, 600A Deadbreak rated separable connector.
What is the primary use of the K656CY cable joint?
The K656CY cable joint is used to join cables in a disconnectable 3-way joint. It is suitable for small vaults, manholes, and direct-buried applications.
What is the continuous current rating of the K656CY?
The K656CY has a continuous current rating of 600 Amp for both 15kV and 25kV voltage classes.
What are the operating voltage limits for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.
What are the operating voltage limits for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.
What is the primary use of the K656CY cable joint?
The K656CY cable joint is used to join cables in a disconnectable 3-way joint. It is suitable for small vaults, manholes, and direct-buried applications.
What items are included in the K656CY kit?
Each kit contains a 3-Way Bus Bar, two units of lubricant, installation instructions, and three straight receptacles.
What are the operating voltage limits for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.
What are the operating voltage limits for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.
How to Install K656CY Deadbreak Receptacles
This guide provides step-by-step instructions for the safe and proper installation of K656CY series deadbreak receptacles, including detailed cable preparation, crimping, and final assembly for splicing and tapping solid dielectric cables.
Estimated time: 2h
Tools needed:
Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Rag, Approved safety solvent, Cable cutter, Wire strippers, 650ATY assembly tool OR 600RRT assembly tool
Supplies needed:
K656CY Receptacle housings, Cable adapters, I, Wye or H Center sections, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Electrical tape (for markers), Conductive copper strip (if using flat metallic tape shielded cable), No. 14 AWG copper wire (for grounding), ECS grounding device (optional)
- Ensure Safety and Inspect Components
DANGER: De-energize all apparatus before beginning installation. Do not touch or move energized products. This installation must be performed by competent personnel trained in high voltage electrical equipment and in accordance with all safety practices and electrical standards. Inspect all supplied parts for damage, correct rating, and compatibility with mating components before proceeding.
- Prepare the Cable Jacket and Slide Initial Components
Wipe the outer cable jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely to ensure maximum available length for crimp growth. If using an ECS grounding device, slide the ECS tube onto the cable 38 inches (96.5 cm). Then, slide the receptacle housing onto the cable a distance of 30 inches (76.2 cm).
- Perform Cable Preparation (Type-Specific)
Refer to the specific cable preparation supplement for your cable type. For Jacketed Concentric Neutral Cable: Remove 13-3/4 inches (34.9 cm) of jacket, bend neutral wires back, and remove 10-1/4 inches (26 cm) of semi-con shield. Mark 1 inch (2.5 cm) from the semi-con end with tape. Bevel the insulation end at 45 degrees for approximately 1/4 inch (0.6 cm). Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end towards the outer jacket. Lubricate the cable and the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker. For Flat Metallic Tape Shielded Cable: Remove 13-3/4 inches (34.9 cm) of outer jacket. Remove 11-1/4 inches (28.6 cm) of tape shield, wrap a conductive copper strip around the edge, and secure with two turns of tape marker. Remove 10-1/4 inches (26 cm) of semi-con shield. Bevel the insulation end at 45 degrees for approximately 1/4 inch (0.6 cm). Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end towards the outer jacket. Lubricate the cable and the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker.
- Prepare Conductor and Secure Retaining Ring
Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the adapter or conductor. The exposed conductor should measure 4 3/4 to 5 inches (12.1 to 12.7 cm). Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches (11.1 to 12.1 cm). If measurements are incorrect, redo the assembly.
- Install and Crimp the Connector
Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; it must be between 6 3/4 and 7 inches (17.1 to 17.8 cm). Confirm that the bolt holes in the crimp connectors are positioned to align properly with the bolt holes of the mating part. Crimp the connectors according to the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar; it must still be between 6 3/4 and 7 inches (17.1 to 17.8 cm). Repeat steps 4-5 for all remaining cables to be joined.
- Assemble Washers and Bolt, Then Torque
Assemble the washers and hex-head bolt in the following order: flat washer against the spade contact, then the Belleville washer (concave side down), followed by the hex-head bolt. Hand tighten the bolt. Clean and lubricate the bolt and washer assembly. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate and Position Receptacle Housing
Apply the supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).
- Complete Receptacle Housing Assembly
Attach the appropriate assembly tool (650ATY or 600RRT). If using the 650ATY tool, ensure the 'U' shaped yoke is over the splice section and the 'C' shaped yoke is over the receptacle housing, then slowly raise the handle to slide the receptacle housing over the splice section. If using the 600RRT tool, slide the receptacle housing over the interface by turning the hex nut on either side of the tool. WARNING: DO NOT place your hand on the threaded rod or guide shaft with the assembly tool in place. Once the housing is fully seated, remove the venting rod. Repeat steps 7-8 for any remaining cables.
- Perform Final Checks and Grounding
Check all cable adapters to ensure they are properly located and remove any vinyl tape markers. Complete the installation of any ECS grounding device according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, forming a small loop and twisting tightly, taking care not to damage the eye. Connect this wire to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.