Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656CY-K0330-S - 600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656CY-K0330-S 600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation…

UPC: 783786426065


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656CY-K0330-S is a robust 600 Amp, 15/25kV separable wye joint package engineered for dependable medium-voltage cable terminations. This comprehensive 3-way joint assembly is equipped with an integrated test point, facilitating safe and efficient electrical testing procedures without the necessity of disconnecting the cable. The package includes high-quality aluminum compression lugs, specifically designed for secure connections with a variety of conductor types. A critical component of the K656CY-K0330-S is its cold-shrinkable jacket seal, which is included to provide a weatherproof and highly durable insulation system. This seal is designed to accommodate cable insulation diameters within the range of 1.090 inch to 1.310 inch, ensuring a tight and protective fit. The separable nature of this joint package simplifies installation and allows for straightforward future modifications or maintenance, thereby minimizing downtime for essential network operations. Its design is well-suited for demanding applications within underground distribution systems, industrial power networks, and utility substations, where a secure and low-maintenance connection is paramount for long-term operational reliability. The inclusion of a test point enhances safety and diagnostic capabilities.
  • 600 Amp current rating for medium-voltage applications
  • 15/25 kV voltage rating with 3-way separable wye joint design
  • Test point included for safe electrical testing without disconnection
  • Cold-shrinkable jacket seal for weatherproof and durable insulation (1.090–1.310 inch cable diameter)

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Wye Joint
Voltage Rating
15 to 25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
25.5000 L
Package Weight (Metric)
11.5670 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp Separable Cable Joints, Straight Receptacle, 35KV, Dead Break, Splice, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 350 or Solid 400 or mmSquared 185.

M655YSR-M0300

600 Amp Separable Cable Joints, Straight Receptacle, 35KV, Dead Break, Splice, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 350 or Solid 400 or mmSquared 185.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, G0240 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 1/0 or Compacted/Solid 2/0. S - Cold Shrinkable Jacket Seal. L0270 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. L0270 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656CY-DP0592548

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, G0240 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 1/0 or Compacted/Solid 2/0. S - Cold Shrinkable Jacket Seal. L0270 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. L0270 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold-Shrinkable Jacket Seal Included.

K656I-K0320-S

600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

K656I-L0380-S

600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.

K656CY-H0270-S

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.
600 Amp Separable Cable Joints, Straight Receptacle, 35KV, Dead Break, Splice, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 700/750, Solid 900. 200ECS Jacket Seal Included.

M655YSR-N0380-S

600 Amp Separable Cable Joints, Straight Receptacle, 35KV, Dead Break, Splice, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 700/750, Solid 900. 200ECS Jacket Seal Included.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K656CY-H2240

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

Does this joint include a test point?

Yes, the K656CY-K0330-S features a 3-way separable wye joint with an integrated test point for safe electrical testing.

What is the current rating of this joint?

The K656CY-K0330-S has a current rating of 600 Amps, suitable for medium-voltage systems.

What is the voltage rating of the K656CY-K0330-S?

The device has a voltage rating of 15/25 kV, suitable for medium-voltage applications.

What is the cable insulation diameter range?

The joint accommodates cable insulation diameters from 1.090 inch to 1.310 inch.

What material is used for the compression lugs?

The compression lugs are made of aluminum, ensuring lightweight and corrosion-resistant connections.

Is the jacket seal cold-shrinkable?

Yes, the package includes a cold-shrinkable jacket seal for weatherproof and durable insulation.

Can this joint be used for underground applications?

Yes, the separable wye joint package is designed for reliable underground distribution systems and industrial power networks.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides detailed instructions for installing K656/K676 series deadbreak receptacles, designed for splicing and tapping solid dielectric cables rated for 600 ampere at 15kV and 25kV. Ensure all safety precautions are followed during installation.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire strippers, Wire brush (for aluminum cable), Safety solvent, Rag, Crimping tool, 650ATY assembly tool (optional), 600RRT assembly tool (optional)

Supplies needed:

Receptacle housings, Cable adapters, I, Wye or H Center sections, Aluminum holding collars, Lubricant, Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (or equivalent), No. 14 AWG copper wire, Electrical tape

  1. Prepare for Installation and Safety Checks

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility. Check the contents of the package to ensure completeness. Read all instructions thoroughly before beginning and have all required tools at hand, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable End

    Wipe the outer jacket clean for a distance of 38 inches (96.5 cm) from the end and cut the cable end squarely. If an ECS grounding device is being used, slide its tube onto the cable a distance of 38 inches. Slide the receptacle housing onto the cable a distance of 30 inches (76.2 cm).

  3. Perform Specific Cable Preparation

    This step requires choosing between two procedures based on your cable type: Jacketed Concentric Neutral Cable (Part A) or Flat Metallic Tape Shielded Cable with Semi-con Shield (Part B). Follow the detailed instructions for your specific cable type, including jacket removal, semi-con shield removal, tape marking, insulation beveling, cleaning with safety solvent, and lubricating the cable and inside of the adapter before sliding the adapter into place until it is flush with the tape marker.

  4. Prepare Conductor and Retaining Ring

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Ensure the length of the exposed conductor measures 4 3/4 inches – 5 inches (12.06 cm – 12.7 cm). Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4 3/8 inches – 4 3/4 inches (11.11 cm – 12.06 cm).

  5. Prepare and Crimp Connectors

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Confirm that all components are positioned correctly and that the bolt holes in the crimp connectors are properly aligned with the bolt holes of the mating part. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be 6 3/4 inches – 7 inches (17.14 cm – 17.78 cm) maximum. Repeat Steps 4 and 5 for all remaining cables to be joined.

  6. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (with the concave side down), then the hex-head bolt. Hand tighten all bolts. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. (67.8 to 81.3 Nm). The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  7. Lubricate and Install Receptacle Housing

    Apply the supplied lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  8. Seat Receptacle Housing with Assembly Tool

    Attach either the 650ATY assembly tool or the 600RRT assembly tool as shown in the product documentation. With the assembly tool in place, slowly operate it to slide the receptacle housing completely over the splice section. Once the housing is fully seated, remove the venting rod. Repeat Steps 7 and 8 for any remaining cables.

  9. Perform Final Checks and Grounding

    Check all cable adapters to make sure they are located properly and remove all vinyl tape markers. Complete the installation of the ECS grounding device according to the instructions included with that device. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect it to a suitable ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.